5179Flood Report_REVISION_2_7Feb2021
Callaghan & Toth
2.0 FLOOD IMMUNITY
The Year 2100 1%AEP flood levels across the north-east corner of the site have been abstracted from a
flood study undertaken by Brisbane Stormwater Management Pty Ltd for the adjoining Erindale
Development in 2014. The relevant flood levels are 100.34 m AHD across the eastern (upstream)
boundary of the site and 99.94 m AHD across the northern (downstream) boundary of the site. Those
Year 2100 1%AEP flood levels are marked on Figures 3.2 and 3.3 hereafter, together with the inferred
Year 2100 1%AEP flood boundary between those two levels.
The proposed lots are seen, in comparison to the 0.5 metre contours on Figure 3.3, to be at least a metre
above the flood profile and will therefore be immune to 100 year flooding, even with a 20% impost on the
design rainfalls for future climate change.
The proposed stormwater detention facilities are also seen on Figure 3.3 to be outside the Year 2100 1%
AEP flood boundary and will therefore have no impact on the storage-routing capacity of the floodway.
5
2035 2 Pearsons Road – Flood Study – Revision 2 Feburary 2021