Original source · versioned page text
Appendix B - Acoustic Report
Your Mates Bowlsy Pty Ltd Reference: #1859d1-B
Your Mates Bowls Pub Date: 6 March 2025
Noise Impact Assessment
3.4 Summary of Noise Goals
A summary of the adopted limiting criteria for this assessment has been presented in Table 7.
Table 7. Adopted limiting criteria
Noise limit, dB
Compliance location Noise source Noise descriptor
Day Evening Night
LAeq,adj,1hr 50 50 --
Residence (for outdoors) All noise sources LA10,adj,1hr 55 55 --
LA1,adj,1hr 65 65 --
LAeq,adj,1hr 35 35 30
Within nearest habitable
room (assuming open All noise sources LA10,adj,1hr 40 40 35
windows)
LA1,adj,1hr 45 45 40
Commercial and retail
All noise sources LAeq,adj,1hr 45[1] -- --
activity (for indoors)
Hospital, surgery or other
medical institution (for All noise sources LAeq,adj,1hr 35[1] -- --
indoors)
[1]
Only applicable when the activity is open for business.
Where indoor noise limits are specified, an attenuation of 7 dB through open windows is assumed
to assess levels on the building’s external façade.