10. 11. b. The existing two 225mm pipes must be removed and replaced with five 600mm x 300mm box culverts as illustrated on SLR drawing Proposed Flood Hazard Mitigation Strategy, Figure 1 dated 30 November 2018; and Cc. Underground service conduits for all utility services consistent with the requirements of condition 15 of this Decision Notice. Any alterations to the existing driveway must be certified by a Registered Professional Engineer of Queensland as being suitable for the intended use. The certification must be submitted to Council prior to the sealing of the survey plan. Emergency access (walkway) The existing elevated walkway (elevated walkway) between the existing dwellings must be amended/extended in accordance with the following: a. That part of the existing walkway in proposed Lot 2 must be demolished; b. The existing walkway in proposed Lot 1 must be extended along the western boundary and then in a northerly direction, generally in accordance with Plan of Development Option 2, to a point above the 1% AEP design event; The walkway must be maintained at a height above the 1% AEP design event; d. The walkway extension must be constructed in accordance with the Barlow Shelley, Walkway Plans & Details Dwg No. SK1 Rev 1 dated 9 August 2017 consistent with the east west walkway details, subject to the boundary fence between proposed Lots 1 and 2 which shall form the western most fencing for the walkway; e. The fencing on the walkway must be consistent with the fencing design identified on Figure 2; and f. The fence on the boundary between proposed Lots 1 and 2 shall be 1800mm high from the ground. The walkway works must be completed by a suitably qualified person prior to the sealing of the survey plan. The walkway works must certified by a Registered Professional Engineer of Queensland prior to the sealing of the survey plan. The certification must include specific reference to the relevant conditions of this approval. Fencing Additional fencing (fencing) at least 1.2m high must be installed as identified on Plan of Development Option 2 in accordance with Figure 2 and Figure 3 as prepared by SLR Consulting. The fencing must be installed prior to the sealing of the survey plan The fencing must include installation of flaps, as described in Figure 3 prepared by SLR Consulting. The flaps must be able to come to rest on a level concrete apron. Signage Floodway warning signage must be placed at the four locations identified on the Plan of Development Option 2. The signage must be installed prior to the sealing of the survey plan and must include: a. Adiagrammatic representation of the flood risk; b. | The wording: FLOODWAY WARNING, RAIN MAY CAUSE FLOOD WATER TO RISE, KEEP OUT OF THE FENCED AREA DURING HEAVY RAIN; c. Flood depth gauges; and
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
1443 - Final Signed Judgement.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.