A B C D E F
1,800 12,860 2,550 9,180 2,550
CAP-R C-ORB @30° ROOF PITCH
D SKY SKY
BAR
SKY BAR
CAP-B ENCLOSED DUTCH GABLE END
C-ORB @30° ROOF PITCH SKY FC-L WITH FEATURE BATTEN C-ORB @30° ROOF PITCH
TRIM TO BUILDERS DETAILS
CAP-R
ENTRY CEILING HEIGHT 3.700
1,300
GUT+FAS W-14
CEILING HEIGHT 3.000
600
600
W-21 W-20 W-18
KITCHEN CEILING HEIGHT 2.550 KITCHEN CEILING HEIGHT 2.550
3,700
1,500
DP
DP X2
DP X2
DP X2
D-15 D-14 W-19 D-13 W-17 W-16 W-15 D-11 W-13
3,000
CLOTHES PST CL PST PST CL
2,550
2,400
2,400
2,400
LINE
(NOM)
HWS
1,050
GAS
MAIN SLAB R.L. 146.950 (NOM) F-OBS F-OBS F
AGG
AGG RN-L
EXISTING G.L.
FINISHED G.L.
01a Southern Eleva on
1:100
01b E F G H
9,180 2,550 12,860 1,800
C-ORB @30° ROOF PITCH CAP-R
SKY SKY
BAR
BAR
ENCLOSED DUTCH GABLE END CAP-B
FC-L WITH FEATURE BATTEN C-ORB @30° ROOF PITCH
TRIM TO BUILDERS DETAILS C-ORB @30° ROOF PITCH
CAP-R
ENTRY CEILING HEIGHT 3.700
1,300
W-14 GUT+FAS
RL 149.715 (NOM) CEILING HEIGHT 3.000
ARB
600
600
KITCHEN CEILING HEIGHT 2.550
3,700
DP
DP X2
DP X2
W-15 D-11 W-13 W-12
3,000
CL PST PST CL PST PST PST PST
2,400
2,400
2,400
GAS
F F-OBS AGG MAIN SLAB R.L. 146.950 (NOM)
EXISTING G.L.
FINISHED G.L.
01a
01b Southern Eleva on
1:100
0 1 2 5 10
Revision Notes. Project Client Drawing Date Author
reitsma
Figured dimensions only are to be taken from this drawing. All works must comply with NCC, local authority and all N EDWARDS RESIDENCE J. + D. Edwards Eleva on 01 11/06/2024 TEAM
All dimensions, bearings, exis ng services, mandatory council relevant geographical/wind category requirements. All
restraints/requirements and proposed levels are to be checked and
verified on site by builder/client prior to commencement of works.
cut and fill ba ers are indica ve only and must be
established and verified by builder/client in rela on to
LOT 13 (No. 146) FERRELLS Scale Revision
Builder
+61 493 062 182 13 Ridgewood Road.
Any discrepancies must be communicated to the designer prior to proposed slab and/or floor levels ROAD Craig Bri en 1:100 A
commencement of works. Please note, builder specifica ons and These drawings are to be read in conjunc on with other Stage
Caloundra signed contracts to take precedence over all Reitsma documenta on. relevant consultants drawings and reports. COOROY Project Number Sheet Number
[email protected] QLD, 4551 DEVELOPMENT APPROVAL
www.reitsma.com.au Australia
© Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
QBCC Lic. No. 1234490 BDAQ Member
QLD 4563 Ph: 0421 338 630 NOT SUITABLE FOR CONSTRUCTION 4661 49 /94
See the original