03
GT-L SCR-L
POOL
1 SERVICES
CONC.
POOL PUMP/ FILTER
TAP
LOCATED UNDER
RAISED POOL SHELL TO ACT AS POOL FENCE - ENSURE
RW-B COMPLIANCE WITH POOL FENCING REGULATION
RW-B
PF-R
TOW 145.90 (NOM)
POOL - RENDERED POOLSHELL WITH TILED TOP
& WATERLINE - REFER ENGINEERS DETAILS
3.4.1 Floor
1:100
Plan - Pool Services
PF-R
PF-R
POOL
BAL-G NOTE - POOL IS REPRESENTATIVE ONLY FINAL DETAILS BAL-G
BAL-G
BAL-G
SUCH AS LOCATION/DEPTH/ STEPS/LEDGES ETC. TO BE
CONFIRMED BY BUILDERS (AVOID DECORATIVE GT-L
DETAILS SUCH AS 45deg ANGLE STEPS/TILING ETC)
SUN DECK 01 SUN DECK 02
AGG AGG
STEP
STEP
STEP
STEP
STEP
STEP
LEDGE
PF-R
PF-R
SK-B POOL FENCING AND GATES IN SK-B
ACCORDANCE WITH LOCAL AUTHORITIES
TOW 147.30 (MIN)
TOW 147.30 (MIN)
PROVISION FOR UMBRELLA FIXIING REGULATIONS + A.S. 1926.1 LOCATION PROVISION FOR UMBRELLA FIXIING
POINT RECESSED INTO CONCRETE DECK TBC ON SITE BY CLIENT/BUILDER POINT RECESSED INTO CONCRETE DECK
R.L. 146.100
PF-S PF-S PG PF-S PF-S
SD GARDEN GARDEN SD
00 UP AGG
02
04
01 ST-C
LAWN 02 LAWN
43,600
R.L. 146.420
B C D 03
UP
ST-C TAP
E F 2 G
12,860 2,550 9,180 2,550 12,860
DP 04 DP
PST PST05 PST PST
STRUCTURAL TIMBER BEAM
GARDEN 1 SURROUND (PAINTED LIGHT
COLOUR) - SEE SECTION/DETAIL
GARDEN
DPx2 DPx2 PST PST DPx2 DPx2
PST PST PST PST PST PST PST PST
1,770
1,770
W-01 W-03 PATIO W-04 OUTDOOR LIVING W-08 W-09 PATIO W-10 W-11
5,490
RAKED SOFFIT RAKED SOFFIT UP UP RAKED SOFFIT UP UP
UP D-01 W-02 UP D-02 UP D-03 D-05 D-06 AGG D-07 D-08
AGG AGG
R.L. 146.900 R.L. 146.900 GT-Lx2
CBT-R CBT-R CBT-R CBT-R CBT-R CBT-R TAP
2400x870
PERG-1 PERG-1
REF-B
GAS 01
2400x870
SL-D
INT
NOTE - 820(MIN) DOOR CLEARANCE REFUSE
CS
SA SA ALL EXPOSED MULLIONS TO HAVE
CS
SA THROUGHOUT TO COMPLY WITH
BBQ COVERPLATES TO MATCH WINDOW LIVABLE HOUSING CODE
W-07
FRAMES (EXTERNALLY AND INTERNALLY) GRAVEL SH
PAINTED TIMBER MASTER
ENS. 02
2400x820
W-05 FRAMED ACID ETCHED
BUILT IN TV UNIT
UP CAVITY SLIDING DOOR E N3000
S UHT.I T E
3000 HT.
CS
BBQ
CBT-R
D-04 W-06 SHR
B E3000
D HT.0 2 MPR BED 03 R.L. 146.900 CP
TF
RH-B TF
SH
3000 HT. MV
CF
R.L. 146.950
3000 HT.
TIM CF FLY RECESSED TRACK FLY MASTER BED
3000 HT.
EXTENT OF
EXTENT OF
3700 HT.
MV DRW
3000 HT.
CF
CBT-R
CONCEALED STRUCTURAL WINDBEAM SA R.L. 146.950
(COVERPLATE OVER TO MATCH
SHR WINDOW FRAME) - REFER ENG. DETAILS
PAINTED TIMBER 'SHAKER'
2400x920
2400x920
MH SA MH
GARAGE DOOR MOTOR
ROBE
CEILING NOGGING FOR
INTERNAL DOORS THROUGHOUT
CUP'B+SH
ROBE ROBE 2400x920
CONCEALED FLUE - TO MANF. DETAILS
MIRROR - BY OTHERS
FIREPLACE TO BE FAN COIL UNIT
2400x2000 ROBE IN CEILING
GD-G
INSTALLED AS PER
CS PAINTED TIMBER MANUFACTURERS DETAILS TBC BY BUILDER
DINING
3.4
DECORATIVE
Floor Plan - Part C 'SHAKER' INTERNAL
DOORS THROUGHOUT
1:100 01 0 1 2 5 10
Revision Notes. Project Client Drawing Date Author
reitsma
Figured dimensions only are to be taken from this drawing. All works must comply with NCC, local authority and all N EDWARDS RESIDENCE J. + D. Edwards Floor Plan - Part C 11/06/2024 TEAM
All dimensions, bearings, exis ng services, mandatory council relevant geographical/wind category requirements. All
restraints/requirements and proposed levels are to be checked and
verified on site by builder/client prior to commencement of works.
cut and fill ba ers are indica ve only and must be
established and verified by builder/client in rela on to
LOT 13 (No. 146) FERRELLS Scale Revision
Builder
+61 493 062 182 13 Ridgewood Road.
Any discrepancies must be communicated to the designer prior to proposed slab and/or floor levels ROAD Craig Bri en 1:100 A
commencement of works. Please note, builder specifica ons and These drawings are to be read in conjunc on with other Stage
Caloundra signed contracts to take precedence over all Reitsma documenta on. relevant consultants drawings and reports. COOROY Project Number Sheet Number
[email protected] QLD, 4551 DEVELOPMENT APPROVAL
www.reitsma.com.au Australia
© Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
QBCC Lic. No. 1234490 BDAQ Member
QLD 4563 Ph: 0421 338 630 NOT SUITABLE FOR CONSTRUCTION 4661 11 /94
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.