Council archive · source document
Information Request OPW17/0552
Officer: Mark Lewis Direct Telephone: 07 53296290 Our Reference: OPW17/0552 Your Reference: 34 Arakoon Cres. 27 September 2017 JE Jamieson, NE Jamieson PO Box 15092 CITY EAST QLD 4002 Dear Sir Information Request Planning Act 2016 I refer to your application and advise that Council requires further information to satisfactorily assess the proposal. application details Application No. OPW17/0552 Street Address: 34 Arakoon Cres Sunshine Beach Qld 4567 Real Property Description: Lot 799 RP 48111 Planning Scheme: The Noosa Plan (3 July 2017) INFORMATION REQUIRED The information requested is set out below: Issue The subject site is mapped in The Noosa Plan as being in a Landslide Hazard Area but the submitted material makes no comment on this issue. Information Required Provide comment from the design engineer that states that the submitted design has considered the landslide hazard and that the proposed structures will remain stable in the long term Issue Insufficient detail has been provided for the rock mattresses. Information Required Provide amended engineering plans detailing dimensions of these elements and confirm whether they are solely for scour protection or are also part of the structural design of the retaining wall Issue Council has concerns with the discharge from the overflow pipes from infiltration pit Information Required Provide amended engineering drawings showing additional detail on the outlets to the rock mattress and demonstrate that runoff will not bypass the gabions during a large rain event. Issue Council requires clarification on the Rainfall intensity – Design event indicated on the submitted plans Information Required Confirm that the ‘5 minute storm at 1:20 ARI 253mm/hr’ event indicated on the submitted plans is in accordance with the Noosa Plan (PSP 5 – Engineering Design Standards – Roads, Drainage and Earthworks – section 4.1). Issue No detail has been provided in regard to the construction methodology/work method for the proposed works Information Required Provide detail in regard to the construction methodology/work method for the proposed works. The detail must include but not be limited to: access for plant, construction materials, workers to the work area erosion and sediment control measures removal of existing stormwater infrastructure in the adjoining reserve area. due date for response to information request The due date for providing the requested information is 27 December 2017. Please advise Council of your response to this information request in accordance with section 13 of the Development Assessment Rules. If you do not provide a response before the due date, it will be taken as if you have decided not to respond to the information request and Council will continue with the assessment of your application. other details You can follow the progress of this application online at www.noosa.qd.gov.au. The “Online Services” page can be accessed via "Quick Links" on the left hand side of the screen. Should you have any further queries in relation to the above, please do not hesitate to contact me on the number above. Yours faithfully, Mark Lewis Coordinator - Engineering [word/footer1.xml] Page 2 of 2 [word/footer2.xml] PO Box 141 P. (07) 5329 6500 [email protected] TEWANTIN QLD 4565 F. (07) 5329 6501 www.noosa.qld.gov.au Page 1 of 2 [word/header1.xml] 3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Information Request OPW17/0552Related documentApplication case desk ↗
About this file
- File size
- 80 KB (small file)
- File type
- DOCX
No other editions are linked here.