Project Urban – 16161                                                                     June 2016



                  techniques to mitigate impacts
                  from     potential   uncontrolled
                  releases from the industrial uses
                  and the sewerage pump station.
                  Control    measures     shall  be
                  designed to prevent contaminants
                  such as heavy metals/toxic
                  chemicals leaving the site. These
                  measures shall be located outside
                  the vegetated buffer area.
                 Details   of     monitoring and
                  reporting requirements to ensure
                  achievement of the listed water
                  quality objectives.
The stormwater discharge from each lot site
shall be designed such that there is no net
increase in the rate of discharge as a result of
the development for storm events up to 100
year ARI.
Acoustic Treatments                                    The Noise Impact Assessment prepared by
An Acoustic Report by an acoustic consultant to        David Moore & Associates confirms that an
be submitted with each application to Council          appropriate noise environment will be
demonstrating that noise will not exceed the           achieved.
following levels-




This report shall identify measures to mitigate
the potential noise impacts and meet the
respective levels identified and include:
                 Buildings to be located adjacent
                  the    western     or    southern
                  boundaries of lots (outside the
                  vegetated buffers), with building
                  to screen the noisier activities,
                  such as loading docks, open yards
                  and other external activities from
                  residents.
                 For lots 1 and 2 continuous plant
                  such as air conditioning and
                  refrigeration plant shall not be
                  mounted on the building roof and
                  located in a manner that provides
                  acoustic shielding from the
                  nearest residences to the west.
Landscaping                                   The proposed development includes a five (5)
Landscaping shall be undertaken in accordance metre wide minimum landscape strip adjacent

Development Assessment Report                                                          Page 18 of 29
Material Change of Use and Operational Work
6 Taylor Court, Cooroy
Log in to download the original file

Town Planning Report.pdf · 932 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.