rev date issued details
Working Drawings
A 28.10.19 NV Building Approval
legend Note:
Setout plans to be included during
contract administration
AC - # aircon. unit
BAL- # balustrade
CLA- # cladding
CLG- #
DP- #
ceiling type
downpipe
-
DR- #
FLF- #
G-#
drain
floor finish
gates
APPROVED PLAN
51901.3604.2
HC hose cock
HR - # handrails
LFT - # lift
MTL - # metal work
NOOSA COUNCIL
PT - # painted finish
PBL - # pebbles
REN - # render
24 MARCH 2020
RFS - # roof system
T- # tile type
SO - # stone
SCN - # screen
SOF - #
STA - #
soffits
stairs
-
STR - # structure
SW sewer
MSC# miscellaneous item
refer to schedules for details
NOTE: all structural elements; including
all slabs, columns, beams, footings and
framing; to be in accordance with
engineer's design and detail.
59,932
68°35'3
0''
A B C D E F A B C D
3m setb 5,904 6,020 6,180 4,130 6,770 2,400 5,904 6,020 6,180
ack
4
2.2
3m setb D17 D20
ack
4.8 4.9
O/D
2
MSC-04 FFL: 2,3 2.1 MSC-04
7 0
STR-03 STR-03
new facade treatment 1 new facade treatment
2.1
D
05
FFL: 2,400
extent of works D
04
FFL: 2,400
existing door extent of works
FLF-03 FFL: 2,400
existing door
ding
D
existing door 03
existing lan
existing door
FFL: 2,400 existing wind
(1.5m window ow
sill)
existing wind exit path of
ow travel existing wind
(1.5m window ow
exit path of exit path of exit path of sill)
travel travel travel
REN-01 proposed ne REN-01 FLF-03
w walkway
REN-01 REN-01
REN-01 SCN-03 DP-01 REN-01 REN-01
DP-01 REN-01 REN-01
SCN-03
line of floor O/D REN-01
over
existing door REN-01
STA-01
STA-01
15 14 13 15 14 13
12 11 10 12 11 10
STR-01 9 8 9 8
7 6 5 4 3 STR-01 7 6 5 4 3
2 1 2 1
SCN-03 SCN-03 SCN-03 SCN-03
SCN-03 SCN-03
water REN-01
RFS-03
sewer RFS-03
M/H
BAL-02
BAL-02
A
3.1
current fire hose reel and
fire extinguisher position
proposed podium bridge
FLF-01
1500 approx.
RL: 5,000 cos
REN-01 REN-01
1
REN-01 REN-01 2
F.H.R FFL flush
(make good existing balustrade)
fall 3
F.E
4
existing podium
new fire hose reel REN-01 5
and fire extinguisher (make good floor
position to comply DR-01 6
finish and raised REN-01
with NCC E1.4 planters where
7
(make good existing balustrade)
(make good existing balustrade)
required) 8
LIFT 9
10
new walkway 11
12
REN-01
REN-01
13
14
FFL flush 15
REN-01
existing podium
line of existing podium over
line of existing podium over
FLF-01
REN-01
REN-01
(make good floor RL: 5,000 cos
finish and raised fall
D
planters where 08
REN-01
required)
REN-01
(make good existing balustrade)
RFS-03
O/D
1 First Floor Plan Entry Area 2. Second Floor Plan Entry Area
1.8 Scale 1:100 1.8 Scale 1:100
a: suite 6, 8 kingfisher drive, peregian beach, qld 4573
p: (07) 5471 3033 Culgoa Resort Stage 2 - Entry Alteration Scale 1:100 @A1
sparks architects www.sparksarchitects.com
5 Quamby Pl, Noosa Heads QLD 4567 Culgoa Point Beach Resort 106 NV First and Second Floor Plan WD 1.8 n
sparks architects pty. ltd. abn 89 124 611 721
qld architect's registration No. 3974 project client job no. drawn drawing dwg no.
GSPublisherVersion 443.1.1.0
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Compiled Approved Plans - 51901.3604 .3.pdfRelated documentApplication case desk ↗
About this file
- File size
- 26.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.