Original source · versioned page text
Appendix O - SDAP Code Responses (002)
Performance outcomes Acceptable outcomes Response
Hospitals
PO27 Development involving a hospital AO27.1 Hospitals are designed and constructed Not Applicable
minimises noise intrusion from a state-controlled using materials which ensure patient care areas
road or type 1 multi-modal corridor in patient meet the following internal noise criteria:
care areas. 1. ≤35 dB(A) Leq (1 hour) (maximum hour
during opening hours).
Statutory note: Noise levels from a state-controlled
road or type 1 multi-modal corridor are to be
measured in accordance with AS1055.1–1997
Acoustics – Description and measurement of
environmental noise.
Note: To demonstrate compliance with the acceptable
outcome, it is recommended that a RPEQ certified
noise assessment report is provided, prepared in
accordance with the State Development Assessment
Provisions Supporting Information – Community
Amenity (Noise), Department of Transport and Main
Roads, 2013.
Vibration
Hospitals
PO28 Development involving a hospital AO28.1 Hospitals are designed and constructed Not Applicable
minimises vibration impacts from vehicles using to ensure vibration in the treatment area of a
a state-controlled road or type 1 multi-modal patient care area does not exceed a vibration
corridor in patient care areas. dose value of 0.1m/s1.75.
AND
AO28.2 Hospitals are designed and constructed
to ensure vibration in the ward area of a patient
care area does not exceed a vibration dose
value of 0.4m/s1.75.
State Development Assessment Provisions – version 2.0
State code 1: Development in a state-controlled road environment Page 17 of 21
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.