18.   A minimum of 4 covered carpark spaces shall be provided on site.
19.   The carparking area shall be designed to comply with the provisions of AS/NZS 2890.1-2004
      for user class 1A with allowance for vehicles to enter and leave the site in a forward gear and
      with a minimum head clearance (headroom) at any point of 2.2m.
20.   All carparking shall be kept and maintained in a condition fit for use.
21.   A sign shall also be provided to indicate that the proposed turning area is a “Turning Area
      Only” and that “No Parking is Permitted”.
Frontage Works
22.   Footpath improvements such as topsoiling, grassing, and tree planting are required to the
      Corsair Crescent Street frontage of the site in accordance with Planning Scheme Policy
      PSP03 Landscaping Plants & Guidelines. Grass shall be couch, free of weeds.
23.   A new 1.5m wide concrete path shall be constructed along the Corsair Street frontage of the
      site in accordance with Council’s design standards and to an alignment that protects any
      significant vegetation or any underground services.
24.   All redundant vehicular crossings to the site shall be removed and replaced by kerb & channel
      and landscaping such as trees and grasses in accordance with Council’s Standard
      specifications prior to commencement of the use permitted by this permit.
Roof Water & Stormwater Drainage
25.   Roof runoff from any new dwelling shall be directed to a rainwater storage system or tank that
      is installed to ensure water from the rainwater storage system or tank is used for external uses
      (such as watering gardens, irrigation, ornamental ponds, water features, topping-up swimming
      pools, outdoor cleaning, etc) and for internal (ground floor) use in washing machine cold taps
      and toilet cisterns. All rainwater tanks are to be designed and installed in accordance with the
      Queensland Development Code (QDC) current at the time of building approval, and shall be
      part of the plumbing application for approval. The location and capacity of the tanks shall be
      clearly shown on the plans submitted for Building Works and Operational Works approval and
      any overflow shall be directed to the road frontage in Corsair Crescent or the stormwater
      drainage system located at the rear of the site or an onsite infiltration system.
26.   All stormwater drainage (including roof water overflow from the rainwater storage system)
      shall be collected and discharged so there is no net increase in stormwater runoff from the
      site. Stormwater drainage permitted to drain from the site shall be discharged to:
      26.1    Council’s existing drainage structure at the rear of the site. Or
      26.2    Council’s kerb & channel street drainage system in Corsair Crescent. Or
      26.3    An onsite infiltration system.
      Construction of drainage infrastructure shall generally be in accordance with drawing number
      SC-1705 A01 drawn by Empire Engineering dated November 2008. The infiltration system
      shall be wholly contained within the site and surface discharge shall not cause scour or
      damage to adjoining properties or adversely affect Council’s sewer main.
      Plans of the drainage design shall be prepared by a Registered Professional Civil Engineer
      and submitted to Council prior to obtaining a Development Permit for Operational Works. The
      maximum discharge of stormwater drainage allowable to Council’s kerb & channel street
      drainage system at any one location is 25 litres/second.
      A Development Permit for Building Works shall not be granted until a Development Permit for
      Operational Works has been issued in regard to the drainage scheme.
27.   All site stormwater drainage shall be by means of a gravity system.


                                                                                    Page 4 of 11

Used in these records

About this file

File size
73 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

SUPERSEDED Amended Decision Notice - 010.2007.00002062.001 [As Published].pdf · 73 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.