C23-035 - Emerald Street (2) - Civil Plans [RFI Response]
Attached to the e-mail OPW22/0316 - Request for Information response.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnSTORMWATER & ROOFWATER DRAINAGE CONSTRUCTION TOLERANCES PRECAST PIPES AND BOX CULVERTS HORIZONTAL - CENTRELINE DEVIATION FROM NOMINATED POSITION +/-100MM VERTICAL - WHERE NOMINATED GRADE FLATTER THAN 1,200 DEVIATION FROM ILL. NOMINATED +/-15MM. WHERE NOMINATED GRADE IS STEEPER THAN 1:200 DEVIATION FROM THE NOMINATED +/-25MM IN ANY CASE THE FOLLOWING ABSOLUTE MINIMUMS SHALL BE MAINTAINED. PIPE MIN DIAMETER GRADE (mm) (%) 300 0.50 375 0.40 450 0.30 525 0.25 600 0.20 675 0.18 750 0.15 900 0.12 1050 or 0.10 GREATER 2. MANHOLES/INLET STRUCTURES ETC. HORIZONTAL - DEVIATION FROM NOMINATED +/—100MM VERTICAL - FLUSH WITH FINISHED SURFACE DISTANCES BETWEEN STRUCTURES TO BE CHECKED PRIOR TO COMMENCEMENT OF LAYING. ANY VARIATION FROM DRAWINGS TO BE REFERRED TO THE SUPERINTENDENT FOR DIRECTION, NOTE: WHERE ROOFWATER LINES CONNECT TO GULLIES, GULLY LOCATION IS DETERMINED BY ROOFWATER LINE NOT DIGITAL DATA PROVIDED 600 FIELD INLET 900 FIELD INLET = 600MM X 600MM FIELD INLET PIT = 900MM X 600MM FIELD INLET PIT ALL INLETS SHALL BE CAST INSITU GRATED INLETS WITH 2X 100 B STUBS. REFER |.P.W.E.A.0. STO. DWG. D-0050 CLASS 2 ALL GRATES TO BE FLUSH TYPE UNO. REFER LONG SECTION FOR CLASS. STORMWATER DRAINAGE NOTES 1 ALL STORMWATER PIPES 375 AND GREATER SHALL BE PRECAST STEEL REINFORCED CONCRETE SPUN PIPES WITH RUBBER RING JOINTS CLASS 3, UNLESS NOTED OTHERWISE ON THE DRAWINGS. PIPES ABOVE 600 MAY BE FLUSH JOINTED. ALL uPVC PIPES SHALL BE CLASS SN8 RRJ U.N.O. GRADE STORMWATER PIPES OBVERT TO OBVERT UNLESS NOTED OTHER WISE. MAINTAIN 20mm DROP THROUGH STRUCTURES BETWEEN OBVERTS OF THE SAME SIZE PIPES. MINIMUM COVER TO STORMWATER PIPES UNDER ROAD PAVEMENTS SHALL BE 600mm UNLESS NOTED OTHERWISE. ALL MANHOLE LIDS SHALL FINISH FLUSH WITH ADJACENT FINISHED SURFACE LEVELS PROVIDE A 100 SUBSDIL DRAIN WITH SOCK DISCHARGING INTO DRAINAGE STRUCTURES FROM UPSTREAM PIPE BEDDING. EXTEND 300mm INTO PIPE BEDDING. GENERAL NOTES 1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH CURRENT LOCAL AUTHORITY SPECIFICATIONS AND STANDARDS. 2. UNLESS SPECIFIED OTHERWISE ALL MATERIALS AND WORK SHALL COMPLY WITH THE RELEVANT AUSTRALIAN STANDARDS. 3. THE CONTRACTOR SHALL VERIFY THE LOCATION AND DEPTH OF EXISTING SERVICES WITH RELEVANT AUTHORITIES BEFORE COMMENCING WORKS. BENCH MARK AND LEVELS TO AHD. 44, NOTWITHSTANDING THAT THE PRESENT AND/OR PROPOSED POSITIONS OF PUBLIC UTILITIES, FITTINGS, PIPES, POLES, MANHOLES, ETC. MAY BE INDICATED ON THE DRAWINGS. NO RESPONSIBILITY WILL BE ACCEPTED BY THE PRINCIPAL FOR THE ACCURACY OF THE PRESENTATION OR THE OMISSION THEREOF. 5. CONTACT 1100 (DIAL BEFORE YOU DIG), ENERGEX, AGILITY (GAS), SANTOS (OIL), ETC. FOR THE EXACT LOCATION OF UNDERGROUND CABLES. 6. WHERE OVERHEAD PUBLIC UTILITY LINES AND SURFACE DRAINAGE WORKS AND/OR UNDERGROUND PIPES, CONDUITS, OR CABLES, EXIST IN THE VICINITY OF THE WORKS, THE CONTRACTOR SHALL TAKE CARE TO PROTECT SUCH FACILITIES FROM DAMAGE, AND IN THE CASE OF ANY DAMAGE OCCURRING TO SUCH FACILITIES, THE MATTER SHALL BE IMMEDIATELY REPORTED TO THE RELEVANT AUTHORITY AND TO THE SUPERINTENDENT. THE COST OF THE NECESSARY REPAIRS OR RENEWALS SHALL BE BORNE ENTIRELY BY THE CONTRACTOR. 7. NATURAL SURFACE LEVELS ARE FROM DIGITAL TERRAIN MODEL AS SUPPLIED BY THE PROJECT SURVEYOR 8. THE CONTRACTOR SHALL NOT ENTER ADJACENT PROPERTIES WITHOUT PRIOR WRITTEN APPROVAL FROM THE PROPERTY OWNER. 9. DESIGN FINISHED SURFACE LEVELS OF STRUCTURES ARE FOR THE CONTRACTOR'S GUIDANCE ONLY. ACTUAL FINISHED LEVELS SHALL BE SET OUT AS DIRECTED ON SITE IN KEEPING WITH THE REQUIREMENTS AND SPECIFICATIONS OF CITY OF GOLD COAST COUNCIL AND ACTUAL FINISHED GROUND LEVELS. STORMWATER PIPE INSTALLATION NOTES 1. REFER PIPE INVERT LEVELS FOR TRENCH DEPTH 2. REFER LAYOUT PLAN FOR DETAILS OF PAVEMENT MATERIAL 3. BEDDING COMPACTION (COMPACTED FILL / SAND BEDDING) COHESIVE MATERIAL = 95% COMPACTION (STANDARD) NON-COHESIVE MATERIAL ~ DENSITY OF 70 MIN, REFER AS1289.65.1 SAND - COMPACT BY FLOODING AND USE OF VIBRATORS 4. BACKFILL COMPACTION COMPACTED GRAVEL LAYER UNDER ROAD 95% COMPACTION (STANDARD) COMPACTED CBRIS GRAVEL 95% - BELOW 300mm (STANDARD) COMPACTED BACKFILL - FOOTPATH / PRIVATE PROPERTY 95% COMPACTION MAX DENSITIES DETERMINED BY STANDARD COMPACTION TESTS TO AS1289.5.1.1 5. REFER STORMWATER LONGITUDINAL SECTION FOR FOR PIPE SIZE AND DEPTHS. 6. TYPE U AND TYPE H SUPPORT BEDDING NOT SUITABLE FOR USE WITH FIBRE REINFORCED PIPES. FOR FIBRE REINFORCED PIPES TYPE HS BEDDING IS REQUIRED. ALL BEDDING TO CONFORM TO AS 3725 7. PIPES ARE TO BE LAID USING CORRECT STRENGTH CLASS UNDER ALL CONSTRUCTION LOADS. BEDDING & COMPACTION 1. COMPACTION TO BE IN ACCORDANCE WITH BCC EARTHWORKS SPECIFICATION. 2. EMBEDMENT AND BACKFILL TO BE IN ACCORDANCE WITH CoGC STANDARDS, CENTRE OF PIT / LIP OF CHANNEL LIP OF CHANNEL SAG GULLY SETOUT POINT CENTRE OF MANHOLE ®& MANHOLE SETOUT POINT CENTRE OF FIELD INLET FIELD INLET PIT SETOUT POINT 0.25m MIN FFL 110.200 PROPOSED BUILDING REFER: STRUCTURAL ENGINEER FOR DETAIL 1 RP_BDY 46 ©5602 0.3m MIN _ < existing suReace-/ \ ‘PROPOSED CONCRETE CHANNEL DATUM RL109.000 REFER TO STRUCTURAL ENGINEER FOR STRUCTURAL DETAILS SECTION = 4240 (AM) [Bh P:007) 9849 e008 ISSUE | DESCRIPTION 4 M:POBOx79, ‘A _| PRELIMINARY ISSUE GAPALABA GLO 4167 B__| ISSUE FOR APPROVAL a:$2/12, 96 MouNT GRavATT | C_ | COUNCIL RFI RESPONSE CAPALABA RD, UPPER MOUNT GRAVATT QLD 4122 engineers THIS DRAWING IS AND IS NOT TO BE REPRODUCED IN ANY FORM AS A WHOLE OR IN PART WITHOUT EXPRESS WRITTEN PERMISSION FROM CMT ENGINEERS, THE EXISTING SERVICES INFORNATION SHOWN HAS NOT BEEN CONFIRMED ON SITE AND IT IS THE CONTRACTORS RESPONSIBILITY TO LOCATE ANY SERVICES RELEVANT PRIOR TO THE START OF CONSTRUCTION. IF IN DOUBT - ASK. Et [email protected] PM 24980 RL 117.567 DATE _| DRAWN | AUTH, | ISSUE STAMP NORTH CITY COUNCIL APPROVAL NUMBER: a0202| DR | Cur fe.1220¢ or | cur ISSUE FOR APPROVAL [12.01.2024 oR | CMT NOT FOR CONSTRUCTION WITHOUT COUNCIL APPROVAL ‘SURVEY INFORMATION SURVEYOR FILE NAVE SCALE BAR MWA& ASSOCIATES — | 14-3702AB RP DESCRIPTION LAND SIZE. LOT 47 ON C5602 O.1012HA, CENT PROROTINIE DESION DATE: DESIGN GHEOK DATE DR CMT QUEENSLAND PROPERTY | PROPOSED COMMERCIAL DEVELOPMENT AT 2 EMERALD |= — _ DEVELOPMENTS STREET, COOROY OR cp AUTHORISED FOR ISSUE . ORIG. SIZE DRAWING TITLE anos hone M STORMWATER DRAINAGE NOTES & DETAILS CHING MENG TAN RPEQ No! 1311 PROJECT NUMBER / SHEET ISSUE C23-035 C201 c
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.