Original source · versioned page text
Town Planning Assessment Report
Attached to the e-mail Lodgement of development application - 184 Calanthe Avenue_ Doonan.
Rural Residential Zone Code
Performance Outcome Acceptable Outcome Response
PO1 Development provides for low AO1.2 The dwelling house may Not applicable - secondary
density, semi-rural living as well as include one secondary dwelling dwelling not proposed.
compatible work from home with a maximum gross floor area of
opportunities, primary production 65m2 and no more than two
and small scale visitor bedrooms.
accommodation, on large allotments
with varying levels of services.
PO2 Development does not result AO2 A distance of not less than Not applicable - the site is not
in the diminished productive 100 metres is provided between a within 100m of Rural zoned
capacity of rural activities on sensitive land use and land within land.
adjacent or nearby properties. the Rural zone that:
(a) is mapped as Agricultural
Land Conservation Area on
the Agricultural Land
Overlay maps in Schedule
2; and
(b) has a property area greater
than 4 hectares.
PO5 Buildings and other structures: AO5.1 Buildings and structures are The proposal is less than 8
(a) are low rise; no more than 8 metres in building metres in height.
height from ground level, providing
(b) do not present an
that they may be up to 9 metres
appearance of bulk to
where the pitched roof but no
adjacent properties, roads
other part of the building or
or other areas in the vicinity
structure exceeds 8 metres.
of the site;
(c) have a low site impact to
maximise the opportunity to AO5.2 Where excavation is
The maximum portion of the
retain natural site required, the maximum portion of exposed external facade is
characteristics, such as the exposed external façade of the less than 8 metres in height.
native vegetation and building cannot exceed 8 metres in
natural landforms; building height.
(d) respect the scale of
surrounding vegetation; and Editor's note—refer to figure AP3-13A
(e) are no more than two
storeys in height. AO5.3 Site cover of all buildings The proposed site cover is
and structures on the site does not 6.91%.
exceed 30%.
Alternative provisions to the QDC
AO5.4 Individual buildings or Alternate solution - refer
roofed structures do not cover report.
more than 500m2 of the site.