        use of any land
        upstream and
        downstream;

    c) adversely affecting
        the flow of water in
        any overland flow
        path; and

    d) adversely affecting
        the privacy or visual
        amenity of
        surrounding property.

Editor's Note—Development
should ensure that filling does
not impact on the amenity
and usability of neighbouring
properties (including loss of
privacy caused by relative
level changes) or offsite
drainage.
PO16                              AO16                                  Complies with PO16
Underground car parking
                                  No acceptable outcome provided        The proposal involves a car
areas are designed to drain
                                                                        parking to accommodate 5x
and function safely during a
                                                                        cars at basement level. A
flood event and power failure.
                                                                        dewatering and flood
                                                                        mitigation strategy has been
Editor's note—Basements                                                 prepared to mitigate flood risk
should have flood immunity                                              at basement level. Further
above the 1%AEP defined flood                                           details are included in
event with alternative means                                            Appendix H, Civil Drawings for
to mechanical pumping used                                              Operational Works prepared
to achieve such immunity.                                               by SCG Engineers.


Hazards


Bushfire Hazard                   AO17                                  Not Applicable
Management
                                  Within a bushfire hazard area         The site is not located within a
PO17
                                  where there is no reticulated water   bushfire hazard area.
Where located in a Bushfire       supply, the premises has:
Hazard Area as shown on the
                                      a) an accessible dam,
Bushfire Hazard Overlay Map
                                          swimming pool or water
in Schedule 2 and not in a
                                          tank available for
                                                                                                           10

Used in these records

About this file

File size
574 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Appendix D - Noosa Plan Code Assessment.pdf · 574 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.