Log in to see the plans as drawn Proposed Gatehouse
Area : 2.3m2 NO
The development must provide a minimum 2 2700mm high (Above EGL) RT
metre wide soft landscaping strip along the Proposed Driveway H
site's front boundary to the reasonable Location and size to be verified on site.
Driveway construction to be in accordance with
satisfaction of Council. Amended plans SEQ R0-050 and local council regulations.
demonstrating compliance with this condition (Exposed aggregate)
must be submitted to Council prior to the pre- Proposed Bin Storage - Unit A
start meeting. Screened from view. 2000 x 850 Concrete Pad Real Property Description
Location and size to be verified. Lot 18 on R.P 56993
Parish of Weyba
Existing blockwork site retaining
Proposed Duplex Development County of March
Area : 807m²
Unit A
First Floor O.M.P.
walls (TBC) with 1800mm high
1500 - Verify
Site Cover : 305.4m² (Orange Hatch) = 37.8%
1670 - Verify
Ground Floor Roof
G.F. Wall
timber boundary fence over. Approximate Pad RL : 2.4m
1200 - Verify
Approx. Ex.
Main Roof Overhang Percentage = 100 %
Bus Stop
1.553 m - Ex. R.L. Approximate G.F. RL FFL : 2.7m Local Authority : Noosa Shire Council.
8550 - Verify 224° 00' 00" 1.678 m - Ex. R.L. Approximate Garage FFL : 2.32m
40.23 m (Flood Certificate Cer19/0181)
Garage Wall Splashproof blockwork fence
Location and size to be verified on site.
1.531 m - Ex. R.L. Landscaping Builder to ensure surface water is to fall
Bin
Bin
Bin
Turn Around away from the proposed building and
Area prevent pooling in excavated locations. -
1200mm high 200 series blockwork
with select horizontal screening over. Existing residence to be demolished. APPROVED PLANS
Max Height 1800mm 7000 - Verify
1244 1470 Proposed Unit A Pool MCU19/0024 & OPW19/0049
Location and size to be verified on site.
WEYBA ROAD
NOOSA COUNCIL
Ground Floor O.M.P.
Landscaping
Ex. Path
7900 - Verify Approx. Pool Fence to QDC/NCC.
First Floor Wall Ground Floor Wall
(By Others)
20 JUNE 2019
7000 - Verify First Floor Wall Proposed Unit A P.O.S -
9714 - Verify Approximately 134m2 private
First Floor O.M.P. open space to be verified onsite.
O.M.P.
Proposed Landscaping
Feature Motorised Gate Pedestrian
590 1220
Blockwork fence
Gate
Feature Landscaping Soft Landscaping - 274.4m2 - Green hatch
5°
314° 00' 00"
7550 - Verify
Hard Landscaping - 152.6m2
20.12 m
134° 00' 00"
Garage Wall 1544 1470
20.12 m
Total Landscaping : 427m2 (52.9%)
6000 - Verify Approx.
4500
Ground Floor O.M.P. Proposed Unit B Pool
6900 - Verify Location and size to be verified on site.
Pool Fence to QDC/NCC.
5°
First Floor Wall (By Others)
Upgrade existing concrete 6000 - Verify 10714 - Verify
path to be 2000mm wide.
Ex. Path
Landscaping
Fill over existing sewer line TBC.
First Floor O.M.P. O.M.P.
4800
Turn Around
Area Proposed Unit B P.O.S
Approximately 59.4 m2 private
Bin
Bin
Bin
open space to be verified onsite.
1.520 m - Ex. R.L. 44° 00' 00" 1.628 m - Ex. R.L.
First Floor Roof
Ground Floor Wall
Ground Floor Roof
1.592 m - Ex. R.L.
1400 - Verify
First Floor Wall
2000 - Verify
2000 - Verify
40.23 m
1400 - Verify
Climate Code Requirements
1.541 m - Ex. R.L. Approx. Location Of Sewer Line. Energy efficiency assessor to confirm
To Be Confirmed Onsite. adequacy of proposed construction.
1800mm high 200 series Provide insulation to N.C.C. code requirements
Proposed Duplex Development or to BERS certification requirements.
blockwork boundary fence. Proposed blockwork site retaining
walls (TBC) with 1800mm high Unit B
timber boundary fence over. Approximate Pad RL : 2.4m Stormwater Note
Approximate G.F. RL FFL : 2.7m All stormwater drainage shall be in accordance
Approximate Garage FFL : 2.32m with A.S. 3500.3.
(Flood Certificate Cer19/0181)
Location and size to be verified on site. All stormwater drainage shall be in accordance
Builder to ensure surface water is to fall with N.S.C. guidelines to minimise erosion
away from the proposed building and and scouring. Stormwater flow other than
prevent pooling in excavated locations. natural overland flow shall not be discharged
Existing residence to be demolished. onto neighbouring property.
Proposed Bin Storage - Unit B All stormwater drainage design is preliminary
Screened from view.
PROPOSED SITE PLAN Location and size to be verified.
and shall be confirmed by a licenced hydraulics
designer.
Scale 1:200 @ A3 1500mm high.
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Carrier Constructions. Reproduction in part or whole is prohibited unless written permission is obtained from Carrier Constructions. Plans are design for use on the job address specified in the titleblock only.
Revision Schedule Client Name: Scott & Andrea Carrier
Sheet Number: 02 Project Number:18-002
Revision Number Revision Description Revision Date Issued by Project Address: 239 Weyba Road, Noosaville
5 D.A. Set 1.0 22/02/2019 AOW
Climate Zone: 2
6
7
D.A. Set 1.1
D.A. Set 1.2
01/03/2019
24/04/2019
AOW
AOW Wind Category: To engineers spec.
Site Plan
8 D.A. Set 1.3 29/04/2019 AOW Project Issue Date: 13/05/2019 Project Status: D.A. Drawing Set 2.0 Scale: As indicated
9 D.A. Set 2.0 13/05/2019 AOW Drawn By:
Document Set ID: 20877529
20865838
Checked/Signed By Director: Aaron Waters
Version: 5,
1, Version Date: 24/06/2019
2, 17/05/2019
06/06/2019
10/06/2019
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.