Log in to see the plans as drawn Line of 8m mark above proposed ground line.
600 600 600 600
Exposed feature outriggers to builders detail.
Select weatherboard cladding fixed
to manufacturers specifications.
Aluminium framed sliding doors to
manufacturers specifications.
Ceiling Height
Frameless glass balustrade with aluminium Rendered 200 series
2700
Joinery
2400
handrail in accordance with NCC regulations 600 300 600 300 blockwork wall to
fixed to manufacturers specification. engineers detail.
Min. 1000mm high.
Rendered 200 series blockwork pier
with SHS over to engineers detail.
Aluminium framed stacker doors to
Ceiling Height
manufacturers specifications.
3000
Joinery
2400
Approved frameless glass pool fence to
manufacturers specifications.
Min. 1200mm high.
Blockwork site retaining walls
(TBC) with 1800mm high timber
boundary fence over.
Approx. Existing Ground Line
- Approx. Proposed Ground Line
APPROVED PLANS SOUTH-WEST ELEVATION
MCU19/0024 & OPW19/0049
NOOSA COUNCIL
20 JUNE 2019
-
900 1410
Exposed truss tails to truss
manufacturers specifications.
Exposed feature outriggers to builders detail.
Select weatherboard cladding fixed Aluminum framed windows
to manufacturers specifications. to manufacturers specification.
Frameless glass balustrade with
aluminium handrail in accordance
Cantilevered concrete suspended with NCC regulations fixed to
slab to engineers detail. manufacturers specification.
1550 1455 Min. 1000mm high.
Select feature batten screen to
Select feature batten screen to manufacturers detail.
manufacturers detail. Rendered 200 series blockwork
wall to engineers detail.
Bin Storage
Approx. Existing Ground Line
Aluminum framed feature window Approx. Proposed Ground Line
to manufacturers specification.
NORTH-WEST ELEVATION
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Carrier Constructions. Reproduction in part or whole is prohibited unless written permission is obtained from Carrier Constructions. Plans are design for use on the job address specified in the titleblock only.
Revision Schedule Client Name: Scott & Andrea Carrier
Sheet Number: 06 Project Number:18-002
Revision Number Revision Description Revision Date Issued by Project Address: 239 Weyba Road, Noosaville
5 D.A. Set 1.0 22/02/2019 AOW
Climate Zone: 2
6
7
D.A. Set 1.1
D.A. Set 1.2
01/03/2019
24/04/2019
AOW
AOW Wind Category: To engineers spec.
Elevations
8 D.A. Set 1.3 29/04/2019 AOW Project Issue Date: 13/05/2019 Project Status: D.A. Drawing Set 2.0 Scale: 1 : 100
9 D.A. Set 2.0 13/05/2019 AOW Drawn By:
Document Set ID: 20877529
20865838
Checked/Signed By Director: Aaron Waters
Version: 5,
1, Version Date: 24/06/2019
2, 17/05/2019
06/06/2019
10/06/2019
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.