Council archive · source document
Appendix D - Engineering Assessment · OPW26/0090
RATIONAL METHOD CALCS PROJECT NUMBER 26022 ADDRESS 28 OVERLANDER AVENUE, COOROY Rainfall Frequency Catchment Peak Discharge Inputs Intensity Factors [-] Coefficients [-] [m3/s] [mm/hr] Area Tc Climate Change Tc Catchment ID fi C10 Notes F39% (0.5EY) F1% C39% (0.5EY) C1% i39% (0.5EY) Tci1% Q39% (0.5EY) Q1% [ha] [min] Factor [-] Site Predev 0.1710 5.00 0.29 0.76 1.15 FOR 1 DEGREE OF WARMING (1DW) 0.85 1.20 0.65 0.91 173 363 0.053 0.157 LOT 1 (Vacant) 0.0540 5.00 0.00 0.70 1.15 FOR 1 DEGREE OF WARMING (1DW) 0.85 1.20 0.60 0.84 173 363 0.015 0.046 LOT 1 (Developed) 0.0540 5.00 0.75 0.85 1.15 FOR 1 DEGREE OF WARMING (1DW) 0.85 1.20 0.72 1.00 173 363 0.019 0.054 LOT 2 0.1170 5.00 0.42 0.88 1.15 FOR 1 DEGREE OF WARMING (1DW) 0.85 1.20 0.75 1.00 173 363 0.042 0.118