BUILDING HEIGHT RESTRICTION LINE (8.0m

 

 

ABOVE PROPOSED é& NAT. GROUND LINE)

 

PAINTED FC SHEETING WITH COVER STRIPS TO
EXTERIOR (NOM.1200w PANELS—WTH
COVERSTRIP SETOUT AS DRAWN)

 

 

 

PAINTED FC SHEETING TO
RETURN DOWN AT CORNER
CEILING HEIGHT

 

 

 

 

 

 

METAL ROOFING (‘CUSTOM ORB’ PROFILE —
GALVANISED FINISH AS SPEC.)

 

TAT

 

 

 

 

 

 

 

 

 

 

 

HAVANA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(UNLESS NOTED OTHERWISE OR ON RAKE)
= * nt t= 1
PAINTED COMPRESSED FC [ 4
2 2 SUNSHADES WITH BRACKETS 7 ‘
| 3/52 AS DETALED \ | | i
“Bg te ul
3g RL 25.880 FLOOR eo we a ‘sf + — =tr—t-]} 4
t_ 1 TT ty —
| | } J \ | ee
t= wW.40omm CLEAR REO‘ FoR | S one ma veel 2x200475 GAL. STEEL POSTS TO le SUNSHINE COAST REGIONAL COUNCIL
@| mo 1 ok revs climes een unne 3 APPROVED
=| NATURAL GROUND LINE (APPROX.) ~ SS (ZNCALUME FINISH) EI APP —_
PROPOSED GROUND LINE (APPROX.) L STAINED TIMBER SCREENING L 2 MAY 2011
© BUILDING LINE OF WESTERN ELEVATION PANELS WTH GATE TO REAR OF 110078 1
CARAGE AS DETAILED MCU
(01 \ WEST ELEVATION (Street Elevation) APPROX. LEVEL OF EXISTING
J % GROUND LINE AT BOUNDARY
4:100
_—
—_—_
ion
=
=
eee
BUILDING HEIGHT RESTRICTION LINE (8.0m —— Ee
ABOVE PROPOSED & NAT. GROUND LINE)
HIGH LEVEL WNDOWS (FIXED & LOUVRE PANELS)
si, PAINTED FC SHEETING WITH COVER STRIPS
== L 10 LOUNGE: WITH FC SUNSHADES AS DETALED (1200w PANELS WITH EXTRA COVER STRIPS
300/400 SPACINGS)
= T |
ss TFS INTED COMPRESSED
CEILING HEIGHT FOR NORTHERN ROOMS (UNO) | ! To 1d |——- SUNSTADES | WH BRACKETS
= = el I tro}= [soe
1000-1200 HIGH BALUSTRADE (SHOWN
3 5s DASHED) AS DETALED — TIMBER,
S| /Bo  SwSTERL & GLASS Pays
SN] S|= I Hh fa re
I
RL 25.880 FLOOR LEVEL || I | L_} _ _
: =

 

 

 

 

 

 

 

 

 

|
|
|
|
|
|
|

1800H REAR FENCE
BCA REQ'TS AS DETAILED

UNE OF POOL BEHIND:

 

 

 

 

 

|

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a a i

 

TWBER & CONCRETE BLOCK FRONT

 

 

BATHROOM WINDOW TO BE = ———1

RECESSED — ‘BOXED’ IN WITH
FIBRE CEMENT SHEETING

 

= GROUND LINE
(SHOWN DASHED)

PROPOSED GROUND LINE

WIN.400mm CLEAR
REQ'D FOR VENTILATION
TO BCA REQ'TS

FENCE AS DETAILED

TIMBER DECK OFF BEDROOM 1 —
NO BALUSTRADE REQ'D (UNLESS
DECK >1M FROM GROUND)

      
  

 

 

The designs & drawings

shown on these plans

are copyrighted and

remain the property of
‘Bluecoast Construction Pty Ltd’
No unauthorised copies

shall be made

 

Issue Amendment

Date

 

 

 

ISSUE TO CLIENT FOR APPROVAL, PRELIMINARY ISSUE TO ENGINEER]

07.04.11

 

 

 

 

 

 

PROJECT DRAWING TITLE DWG No,
CONST UCTIONSy — Hooswiteo€ OLD 456 PROPOSED RESIDENCE for | & N BANKS | ELEVATIONS- WEST & NORTH] A-04
ueC Ooast Licence Mot teste 24 STEVENS STREET, SUNSHINE BEACH, QLD on Oe ai =

 

 

 

 

 

Used in these records

About this file

File size
11.1 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

APPROVED PLANS MCU11_0078.pdf · 11.1 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.