Original source · versioned page text
26-0188 Structural Issue A
Attached to the e-mail Combined Application MCU26/0034 & OPW26/0056 - DA Form 1, Owners Consent, Civil Plans - 117 Shorehaven Drive Noosaville.
FLOOR FRAMING SCHEDULE:
MARK SIZE DESCRIPTION
BR1 152x76x6.0 Rectangular Hollow Section Bearer (continuous span)
(Alloy & Temper - 6061/T6) dary
d Boun
Projecte
DJ1 200x50x3.0 Rectangular Hollow Section Deck Joist (single span)
(Alloy & Temper - 6060/T5 or 6106/T6)
SJ1 200x50x3.0 Rectangular Hollow Section Structural Joist (single span)
(Alloy & Temper - 6060/T5 or 6106/T6) ary
y Bound
Propert
TR1 200x50x3.0 Rectangular Hollow Section Trimmer (single span)
(Alloy & Temper - 6060/T5 or 6106/T6)
ST1 80x50x6.0 Rectangular Hollow Section Strut
(Alloy & Temper - 6060/T5 or 6106/T6)
C1 315Ø Jetted Concrete Piles Column
Cantilevered framing must not
NOTES: be fixed to revetment wall.
1. All floor joists to be at 450mm crs UNO. Aluminum plate to end of
framing as specified by builder.
SJ1
NOTE:
All fixings, connectors, plates and angles
BR1
BR1
BR1
BR1
DJ1
TR1
TR1
C1 C1 C1 C1
to be Stainless Steel grade 316 or aluminium
315 outer diameter tube.
Filled with concrete, N50/20.
SJ1
Provide 6/N12 bars
and R10 helix with 150mm pitch.
NOTE:
All Steel to be protected
as per AS/NZS 2312.1
Hidden line indicates
location of ST1. Typical.
Approx Broadwater Bottom
NOTE: (Typical)
All dissimilar metals to be SJ1
isolated to prevent corrosion
BR1
BR1
BR1
BR1
DJ1
TR1
TR1
C1 C1 C1 C1
Existing Residence
315 outer diameter tube.
SJ1
Filled with concrete, N50/20.
Provide 6/N12 bars
and R10 helix with 150mm pitch.
(Typical) (Typical)
TBC by specilist contractor
Property Boundary
Revetment Wall
65mm
cover
315mm Ø
Pile depth to be confirmed with
specilist contractor and install piles
achieve minimum working loads:
dary Vertical load capacity - 21kN
d Boun 315mm Ø
Projecte Horizontal load capacity - 4kN
Confirm depth with engineer prior to construction
C1 - 315Ø PILE REINFORCEMENT
ry
y Bounda
Propert
Issue Made By Date Description PROPOSED NEW JETTY Scale : 1:100 NOTES:
A LML 09/04/26 Issue for construction
at LOT 683 (#117) SHOREHAVEN DRIVE, NOOSAVILLE
REVISION
Job No.: 26-0188 1. Do not scale drawings.
2. Scale is correct at A3.
BUILDER: PONTOON WORKS
Dwg No.: S02 3. Check and verify all dimensions
Designed By : L.M.LITTLE Drawn By : LML Date : 09/04/26 prior to commencement of work.
Certified By : B.R. CROMAR BEng (Civil) MIEAust CPEng RPEQ NER Date : 09/04/26 Ph: (07) 5444 5578 Email: [email protected] FLOOR FRAMING LAYOUT
See the original