Original source · versioned page text
Attachment 4 - Officer Report Dated 12 September 2023
Very large file (71.2 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Original PDF page 41, section 1. The text section number identifies this passage in the reader.
ELEVATION / SECTION LEGEND
BAL-1 Galvanised Steel Baulstrade
C1 Structural Column
CLD-1 Cladding Type 1 - Composite Timber Cladding
CLD-2 Cladding Type 2 - Horizontal Weatherboard (White)
CLD-3 Cladding Type 3 - Semi-Translucent Cladding
D.TR. Drinking Trough
EG Eaves Gutter
FN-1 Timber Fencing
CLD-1 CLD-2 CLD-3 FN-1 BAL-1 RN-1 / PF-1 MRS Metal Roof Sheeting
Composite Timber Horizontal Semi-Translucent Timber Fence Galvanised Steel Render / Paint RW Retaining Wall
Cladding Weatherboard Cladding Balustrade Finish (White) RN-1 Render Finish (White)
(White)
MRS MRS
itch 10.0° P
10.0° P itch
PF-1
MRS
22.200 22.200
EG EG EG
Roof EG Roof
CLD-3
EG C1
CLD-2 BAL-1 MRS
CLD-1
FN-1 CLD-1 C1
EG
19.200 19.200
Dining Dining
C2 C2 C2 C2
CONC
16.700 16.700
Sports Hall Sports Hall
1 South Elevation
- Scale 1:100
RL: 26,074
Timber Battens MRS
itch
1 °P
0.0
MRS RL: 24,141
EG CLD-3 MRS
10.0° P
itch
Camp Signage
EG MRS
C1 CLD-3 C1 C1 CLD-2 C1 C1 C1 CLD-1
22.200 22.200
Roof EG Roof
C1
BAL-1 EG
CLD-2 CLD-2
FN-1 CLD-1
19.200 19.200
Dining Dining
16.700 16.700
Sports Hall Sports Hall
2 West Elevation
- Scale 1:100
Revision Project Architect Stage Project No.
01 Development Approval 25/08/2022 CYC Noosa Campsite CG DEVELOPMENT APPROVAL 1302-01 Elevations 2 - Communal Area
48 Kabi Road Cootharaba QLD
Client
Christian Youth Council
Drawn
MF/MB
Status
PRE-CONSTRUCTION (NOT FOR CONSTRUCTION)
Scale
1:100 at A1 A-DA-CA-09.02 01
(07) 3251 6900 [email protected] Elevation Architecture Pty Ltd ACN 606 170 807 © Copyright reserved this document is and shall remain the property of Elevation Architecture. Unauthorised use of this document in any form whatsoever is prohibited. All information to be printed in colour. Figured dimensions take precedence over scale dimensions. Contractors must verify all dimensions on site before commencing any work or making shop drawings. P:\Data 1\1302-01 CYC Noosa Campsite\5.2 Development Application\5.2.1 ArchiCAD\1302-01_Communal DA 24.pln
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.