Att 3 - Landscaping - RFI Response · MCU21/0117.01
notes :
1 The designs, drawings and specification are copyright and always
remain the property of Blackburne Jackson Design Pty Ltd.
2 Before commencing construction:
-Verify all dimensions and levels.
-Verify location and levels of all services on site.
-Verify that floor levels and finished levels will enable connection to
services.
LANDSCAPE NOTES/ SPECIFICATION LEGEND PLANT SCHEDULE 3 Do not scale this drawing. When in doubt refer to Architects.
issue amendment log by date
CROSS REFERENCING : MULCH: ENSURE LEGEND IS CROSS REFERENCED NO. CODE BOTANICAL NAME COMMON NAME POT SIZE POT SIZE FLOWER SUGGESTED A OPERATIONAL WORKS ISSUE KM 04-10-23
WITH SPECIFICATION NOTES AND FINISHES MATURE MATURE
HEIGHT SPREAD COLOUR POT SIZE B OPERATIONAL WORKS ISSUE NQ 14-11-23
ENSURE LANDSCAPE PLANS ARE READ IN CONJUNCTION WITH ALL MULCH GARDENS TO A MINIMUM DEPTH OF 75mm WITH MIN. 10mm SCHEDULE. HEIGHT SPREAD
CONTRACT DOCUMENTS INCLUDING BUT NOT LIMITED TO ALL SIZE MAX. 25mm SIZE FOREST LITTER MULCH FROM MATURE TREES, C OPERATIONAL WORKS ISSUE NQ 05-12-23
TREES & LARGE SHRUBS D OPERATIONAL WORKS ISSUE NQ 19-12-23
CONSULTANTS DRAWINGS AND ALL WRITTEN SPECIFICATIONS. SHRUBS FREE FROM WOOD SLIVERS.
1 BAC cit BACKHOUSIA citriodora Lemon Scented Myrtle 6.0m 2.0m 1.8m 1.0m white 45L E OPERATIONAL WORKS ISSUE NQ 13-03-24
CLARIFICATIONS : ESTABLISH A MINIMUM DEPTH OF 75mm WITH AGED AND COMPOSTED
F OPERATIONAL WORKS ISSUE NQ 19-03-24
MULCH PRODUCED BY A CHIPPER BEING A COMBINATION OF LEAF, 4 CUP ana CUPANIOPSIS anacardioides Tuckeroo 6.0m 5.0m 1.8m 1.0m white 45L
SHOULD THE CONTRACTOR HAVE ANY QUERIES OR QUESTIONS OR BARK AND TIMBER. TURF G OPERATIONAL WORKS ISSUE NQ 16-05-24
DISCOVER ANY DISCREPANCIES IN DOCUMENTATION OR CONTRACT
4 ELA eum ELAEOCARPUS eumundii Eumundi Quandong 10.0m 3.0m 1.8m 0.6m cream 45L
DOCUMENTS HE/SHE MUST CONTACT THE CONTRACT ADMINISTRATOR SOIL LADEN TUB GRINDINGS WITH HIGH FINES CONTENT WILL NOT BE
3 ELA obo ELAEOCARPUS obovatus Hard Quandong 6.0m 3.0m 1.8m 1.0m white 45L
OR LANDSCAPE ARCHITECT PRIOR TO TENDERING AND CONSTRUCTION ACCEPTABLE. DO NOT MOUND MULCH HARD UP AGAINST PLANT
FOR CLARIFICATION. STEMS. 2 MEL qui MELALEUCA quinquenervia Paperbark 9.0m 3.0m 1.8m 1.0m cream 45L
TURF : 2 STE sin STENOCARPUS sinuatus Firewheel Tree 10.0m 3.0m 1.8m 0.9m red 45L
EXISTING SERVICES: GENERAL PLANTING
MEDIUM SHRUBS & FOLIAGE PLANTS
ALL TURFING IS TO BE 'A' GRADE WINTERGREEN TURF WITH MINIMUM
BEFORE COMMENCING GROUNDWORKS, LOCATE AND MARK EXISTING
25mm THICKNESS OF SOIL. TURF TO BE LAID ON 100mm TOPSOIL AS 8 ACM red ACMENA smithii 'Redhead' Redhead Lilly Pilly 4.0m 1.5m 0.2m 0.2m red 140mm
UNDERGROUND SERVICES.THE CONTRACTOR MUST CARRY OUT A DIAL
PER "AS4419" SUBGRADE TO BE CULTIVATED TO 100mm PRIOR TO
BEFORE YOU DIG SEARCH PRIOR TO ANY WORKS ON SITE. DO NOT
TOPSOIL BEING SPREAD. TURF IS TO BE LAID USING STRETCHER BOND 12 ACM sub ACMENA smithii 'Sublime' Sublime 5.0m 2.0m 0.5m 0.3m white 200mm
EXCAVATE BY MACHINE WITHIN 1m OF EXISTING UNDERGROUND
PATTERN WITH BUTT EDGES, PEGGED ON STEEP SLOPES.
SERVICES. 31 ALP cae ALPINIA caerulea Native Ginger 1.5m 1.0m 0.5m 0.2m white 140mm
AS SOON AS PRACTICABLE AFTER LAYING, ROLL THE TURF WITH A TREES AND PALMS 17 ALP zer ALPINIA zerumbet Shell Ginger 3.0m 1.0m 0.5m 0.2m white 140mm
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO ALL
ROLLER WEIGHING NOT MORE THAN 90KG PER METRE OF WIDTH FOR
SERVICES, WHETHER NOTED ON THE DRAWINGS OR OTHERWISE, AND 4 BAN rob BANKSIA robur Swamp Banksia 2.0m 2.0m 0.5m 0.3m green 200mm
SANDY OR LIGHT SOILS.
SHALL MAKE GOOD ANY DAMAGE CAUSED AT THE CONTRACTORS COST.
WATER AS NECESSARY TO KEEP THE SOIL MOIST TO A DEPTH OF 18 CAL ros CALLISTEMON spp 'Rose Opal' Rose Opal 2.0m 1.5m 0.4m 0.3m red 200mm
100mm.
TURF TO BE MOWN TO A HEIGHT OF 50mm. 8 CAL sli CALLISTEMON viminalis 'Slim' Slim 3.5m 1.0m 0.3m 0.2m red 140mm
PREPARATION OF NEW GARDEN BEDS FOR PLANTING:
TURF FINISH SHALL BE DIVET AND WEED FREE. 2 COR pin CORDYLINE 'Pink Diamond' Pink Diamond 1.8m 0.8m 0.6m 0.3m white 200mm consultants:
ENSURE THAT ALL RUBBISH, RUBBLE, WEEDS, GRASS AND DEBRIS IS
DELIVER THE TURF WITHIN 24 HOURS OF CUTTING, AND LAY WITHIN 36
REMOVED FROM GARDEN AREAS PRIOR TO PLANTING.
HOURS.
5 CRI ped CRINUM pedunculatum Swamp Lily 1.0m 1.0m 0.6m 0.4m white 200mm STRUCTURAL ENGINEER :
AN UNEVEN SURFACE FINISH IS NOT ACCEPTABLE. [company name]
CULTIVATE EXISTING SUBGRADE TO A MINIMUM DEPTH OF 150mm. 4 DOR exc DORYANTHES excelsa Gymea Lily 2.0m 2.0m 0.4m 0.4m red 300mm PH : [number] [@email here]
REMOVE ANY ROCKS, STICKS OR OTHER DEBRIS GREATER THAN 25mm
IRRIGATION: 4 MEL cla MELALEUCA spp 'Claret Tops' Claret Tops 1.5m 1.0m 0.3m 0.2m white 200mm CIVIL ENGINEER :
DIAMETER THAT HAVE BEEN BROUGHT TO THE SURFACE THROUGH
[company name]
CULTIVATION. AMEND EXISTING SOIL BY MIXING WITH ECO PK 13 MEL mal MELASTOMA malabathricum Blue Tongue 1.5m 1.0m 0.2m 0.15m mauve 140mm PH : [number] [@email here]
THE CONTRACTOR SHALL SUPPLY AND INSTALL AN AUTOMATICALLY
PASTEURISED COMPOST OR EQUAL APPROVED. HYDRAULIC ENGINEER :
CONTROLLED WATERING SYSTEM TO THE EXTENT OF LANDSCAPE 6 RHA exc RHAPIS excelsa Broadleaf Lady Palm 1.5m 1.0m 0.3m 0.2m 140mm
WORKS WITHIN THE SITE EXCLUDING ROAD RESERVE AS SHOWN ON [company name]
USE ONLY SUN 'HARDENED' PLANTS. ENSURE HEALTHY ROOT SYSTEM PH : [number] [@email here]
TO ALL PLANTS TO BE USED. UNDER NO CIRCUMSTANCES ARE ROOT
THE DRAWINGS. ALL GARDEN AREAS AND TREES ARE TO BE DRIP 4 SYZ bea SYZYGIUM spp 'Beach Ball' Beach Ball 1.5m 1.5m 0.4m 0.3m white 200mm
BOUND PLANTS TO BE USED.
SYSTEMS, TURFED AREAS ARE TO BE POP-UP SYSTEMS. THE SYSTEM ELECTRICAL & MECHANICAL ENGINEER :
SHALL BE DESIGNED TO PROVIDE THE CORRECT AMOUNT OF WATER TO 4 SYZ bus SYZYGIUM australe Bush Christmas Bush Christmas 3.0m 1.5m 0.4m 0.3m white 200mm [company name]
THE SPECIFIED PLANTS IN ORDER TO KEEP THEM IN NORMAL PH : [number] [@email here]
CULTIVATE EXISTING SUBGRADE TO A MINIMUM DEPTH OF 150mm. 42 SYZ sup SYZYGIUM australe 'Superior' Superior 3.0m 1.2m 0.4m 0.3m white 200mm
REMOVE ANY ROCKS, STICKS OR OTHER DEBRIS GREATER THAN 25mm SEASONAL GROWTH.
DIAMETER THAT HAVE BEEN BROUGHT TO THE SURFACE THROUGH 30 WES fru WESTRINGIA fruticosa Native Rosemary 2.0m 1.5m 0.4m 0.3m purple 200mm
IF PLANTING AREAS ARE ON PODIUM OR IN PLANTER BOXES HEAD
CULTIVATION. IMPORTED TOPSOIL 6 ZAM fur ZAMIA furfuracea Cardboard Palm 2.0m 1.0m 0.4m 0.4m N/A 300mm
CONTRACTOR MUST COORDINATE WITH IRRIGATION DESIGNER AND
SOIL INSTALLATION & DEPTHS
SUBCONTRACTORS TO ENSURE CONDUITS AND WATER LINES ARE SPREADING & CLUMP FORMING GROUNDCOVERS
1. PLANTING AREA TOPSOIL DEPTH – 300MM SQ.
I N C O R P O R AT E D W H E R E N E C E S S A R Y D U R I N G B U I L D I N G
2. TREE PLANTINGS IN GARDEN BED – 700MM SQ.
CONSTRUCTION. 10 CAR des CARISSA macrocarpa 'Desert Star' Desert Star 0.6m 0.5m 0.15m 0.15m white 140mm
IMPORT CERTIFIED FIRE ANT FREE TOPSOIL COMPLYING WITH "AS 0.7m 0.4m 0.2m 0.2m blue
THE IRRIGATION SYSTEM MUST BE OPERABLE PRIOR TO OR 88 DIA cae DIANELLA caerulea Flax Lily Tubestock
4419(1998)".
IMMEDIATELY AFTER THE INSTALLATION OF PLANT MATERIAL INTO
THEIR FINAL LOCATIONS. ADJOINING PATHS AND ROADWAYS ARE NOT 164 DIA lit DIANELLA congesta 'Little Jess' Little Jess 0.3m 0.3m 0.2m 0.2m blue 140mm
ALL MATERIALS IMPORTED TO THE SITE ARE TO BE CERTIFIED FREE OF
FIRE ANTS. TO BE AFFECTED BY LEVELS OF OVER SPRAY LIKELY TO IMPEDE OR 30 DIE gra DIETES grandiflora Fairy Lily 1.0m 1.0m 0.3m 0.3m white Tubestock
ADVERSELY AFFECT PEDESTRIAN/VEHICULAR MOVEMENT/COMFORT/
SAFETY. THE IRRIGATION CONTRACTOR WILL INSPECT THE SITE PRIOR 30 FIC nod FICINIA nodosa Knobby Club Rush 1.0m 1.0m 0.2m 0.2m N/A tubestock
SPREAD MULCH OVER ENTIRE PLANTING ZONE. FOR PLANTING IN TO LODGEMENT OF TENDER AND TAKE INTO CONSIDERATION IN THE
DESIGN, SUCH THINGS AS SUB-SOIL TYPES, PROPOSED GARDEN/ 25 HAR mee HARDENBERGIA violacea 'Meema' Meema 0.5m 5.0m 0.2m 0.2m purple 140mm
MULCHED AREAS SPREAD MULCH AWAY FROM PLANTING ZONE TO
ENSURE MULCH DOES NOT COME IN CONTACT WITH STEM OF PLANTS. TOPSOIL TYPES, AREA SIZES AND RESTRICTIONS AND GROUNDWATER 4 HYM lit HYMENOCALLIS littoralis Spider Lily 0.7m 0.7m 0.3m 0.2m white 140mm
CONDITIONS. .
TREES, SHRUBS AND GROUNDCOVERS: 30 JUN usi JUNCUS usitatus Common Rush 1.0m 0.4m 0.3m 0.2m N/A 140mm
A PROVEN SUB-MULCH TRICKLE (NETAFIM) OR EQUIVALENT
REFER PLANTING DETAILS. IRRIGATION WILL BE PREFERRED. THE SYSTEM SHALL INCORPORATE A 22 LIR str LIRIOPE muscari 'Stripey white' Stripey white 0.4m 0.4m 0.1m 0.1m Purple 140mm
RAIN SENSOR AND INTERFACED CONTROL SYSTEM, WHICH REDUCES
OR SHUTS OFF IRRIGATION DURING EFFECTIVE RAIN PERIODS.
26 LOM con LOMANDRA confertifolia Matting Lomandra 0.3m 0.5m 0.15m 0.15m cream 140mm
CONTRACTOR IS TO ARRANGE NURSERY VISIT WITH LANDSCAPE
ARCHITECT OR CLIENT TO SELECT AND INSPECT PLANT SPECIES PRIOR 60 LOM hys LOMANDRA hystrix Mat-rush 1.0m 1.0m 0.4m 0.2m cream Tubestock
TO SITE DELIVERY. PIPES SHALL PASS UNDER ALL DRIVEWAYS, SOLID CONCRETE AREAS
AND PAVED AREAS REQUIRING IRRIGATION ACCESS. 12 LOM lim LOMANDRA 'Lime Tuff' Lime Tuff 0.7m 0.7m 0.4m 0.2m cream 140mm
ALL TREES AND PLANTS ARE TO MEET 'NATSPEC' GUIDELINES OF TERMINATE PIPES 300MM CLEAR OF HARD PAVED AREAS AND
STRUCTURES, SEAL ALL PIPES TO PREVENT INGRESS OF SOIL AND 42 LOM lon LOMANDRA longifolia Mat Rush 1.0m 1.0m 0.4m 0.2m cream Tubestock
HEALTH AND FORM. ALL TREES WILL NEED TO BE STAKED SECURELY
TO PREVENT PLANT DAMAGE UNTIL ESTABLISHED. REFER TO DETAIL CONCRETE SLURRY. 27 MOL cap MOLINERIA capitulata Palm Grass 1.5m 1.0m 0.3m 0.3m N/A 140mm
FOR STAKE SIZES AND METHOD.
AT NO TIME SHALL THIS SPECIFICATION TAKE PRECEDENCE OVER THE 29 MYO bon MYOPORUM boninense Boobialla 0.6m 1.5m 0.1m 0.2m white 140mm
ENSURE NURSERY STAKES, TIES AND LABELS ARE REMOVED AFTER MANUFACTURER'S INSTRUCTIONS. ALL WORKS SHALL BE IN
PLANTING. ACCORDANCE WITH RELEVANT AND CURRENT AUSTRALIAN 16 MYO par MYOPORUM parvifolium Fine leaved Myoporum 0.3m 1.5m 0.1m 0.2m white Tubestock
STANDARDS AND LOCAL AUTHORITY REQUIREMENTS.
20 PAN jas PANDOREA jasminoides Pink Bower of Beauty climber climber 0.2m 0.2m pink 140mm
ENSURE THAT THE TOPSOIL LEVEL OF THE PLANT ROOT BALL IS 20mm
BELOW THE FINISHED SURFACE OF THE SOIL SURROUNDING THE HOLE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO ALL 12 WES mun WESTRINGIA 'mundi' Native Rosemary 2.0m 1.5m 0.4m 0.3m purple 200mm
BY BACKFILLING AS REQUIRED. SERVICES, WHETHER NOTED ON THE DRAWINGS OR OTHERWISE, AND
SHALL MAKE GOOD ANY DAMAGE CAUSED AT THE CONTRACTORS COST.
PROVIDE AN ON-SITE NURSERY FOR HOLDING PLANT STOCK ON SITE
FOR MORE THAN 48 HOURS, OF SUFFICIENT SIZE, WITH PROVISION FOR IRRIGATION IS TO BE CONNECTED TO TANKS ON SITE. IF TANKS ARE
WATERING. NOT USABLE CONTRACTOR IS TO COMPLY WITH STATE AND LOCAL
IF DIRECTED, POT PLANTS INTO LARGER SOIL-FILLED CONTAINERS TO GOVERNMENT WATER RESTRICTIONS AT TIME OF PLANTING AND
PREVENT THEM BECOMING ROOT BOUND IF THERE IS AN UNFORESEEN MAINTENANCE.
DELAY. THE CONTRACTOR SHALL BEAR THE COST OF POTTING ON. DO
NOT CARRY OUT POTTING ON UNLESS AUTHORISED. THE CONTRACTOR SHALL REFER TO HYDRAULIC ENGINEERING
DRAWINGS FOR MAINS TAKE OFF LOCATION AND RPZ LOCATION.
OPERATIONAL WORKS
NOT FOR CONSTRUCTION
CHECKED : ……...………………………………….
A R CHIT E CT UR E | L A NDS CA P E | INT E R IOR | P ROJECT MA NA G E ME NT
37 Aerodrome Rd Maroochydore Qld
P.O. Box 154 Cotton Tree QLD 4558 phone 07 5443 3200
email [email protected] fax 07 5443 4030
project:
PROPOSED TOWNHOUSE DEVELOPMENT,
54 ELM ST. & 5 PEARL ST. COOROY
client:
ALTUM
title:
LANDSCAPE NOTES &
SCHEDULES
north date: SEP 2023
drawn: BM
checked: GC
scale @ A1 : N.T.S
scale @ A3 : N.T.S
project/drawing no. sheet: A1
7283_L01-01_G
GSPublisherVersion 1510.0.59.0
7283-26-Cooroy.pln printed: Thursday, 16 May 2024 1:54 pm
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 3 pages
Page 2
S T R E E
GATE
8 ACM sub 1 ELA obo notes :
14 MOL cap
1 The designs, drawings and specification are copyright and always
GATE
remain the property of Blackburne Jackson Design Pty Ltd.
GATE 10 LIR str
2 CUP ana
2 Before commencing construction:
GATE
4 DIA cae
01 02 03 04 05 06 07 08 -Verify all dimensions and levels.
-Verify location and levels of all services on site.
-Verify that floor levels and finished levels will enable connection to
10 DIA cae services.
E L M
8kL RAINWATER TANK
ON BODY CORP
3 Do not scale this drawing. When in doubt refer to Architects.
MANAGED ZONE
6 ALP zer
issue amendment log by date
A OPERATIONAL WORKS ISSUE KM 04-10-23
B OPERATIONAL WORKS ISSUE NQ 14-11-23
C OPERATIONAL WORKS ISSUE NQ 05-12-23
18 DIA lit D OPERATIONAL WORKS ISSUE NQ 19-12-23
6 ALP zer 20 DIA cae E OPERATIONAL WORKS ISSUE NQ 13-03-24
105.4m F OPERATIONAL WORKS ISSUE NQ 19-03-24
G OPERATIONAL WORKS ISSUE NQ 16-05-24
7 WES mun 8 ACM red
2 HYM lit 2 HYM lit
EXISTING TREES 4 SYZ sup 10 DIA cae 12 DIA lit 3 ZAM fur 12 DIA lit 3 ZAM fur
1 MYO bon 1 MYO bon
TO BE RETAINED
& PROTECTED
FROM DAMATE
6 MYO bon
REFER 7883_L03-02 FOR CONTINUATION
4 LOM lim
8kL RAINWATER TANK
ON BODY CORP
1 ELA obo
MANAGED ZONE
8 SYZ sup 6 LOM lon 8 CAL sli 6 LOM lon 8 SYZ sup 10 LOM lon
6 DIA lit 6 DIA lit
consultants:
4 PAN jas
107.4m
107.2m
107.0m
106.8m
106.6m
106.4m
STRUCTURAL ENGINEER :
[company name]
106.2m
PH : [number] [@email here]
8kL RAINWATER TANK
ON BODY CORP CIVIL ENGINEER :
MANAGED ZONE [company name]
PH : [number] [@email here]
6 ALP cae
HYDRAULIC ENGINEER :
106.2m [company name]
PH : [number] [@email here]
ELECTRICAL & MECHANICAL ENGINEER :
10 LOM lon 3 MOL cap GATE [company name]
PH : [number] [@email here]
4 PAN jas 9 MEL mal
105.6m
09 10 11 12
10 DIA cae
2 ELA eum
8 PHO gla
4 PAN jas
8 ALP cae
12 MYO bon
10 LOM lon
24 DIA cae
STEPPER ACCESS PATH WITH
106.4m GRAVEL SURROUNDS TO DETAIL STEPPER ACCESS PATH WITH
GRAVEL SURROUNDS TO DETAIL
4 PAN jas GARDEN EDGE TO DETAIL
GARDEN EDGE TO DETAIL
10 DIA cae
GATE
8 DIE gra 7 PHO gla
4 MYO bon 4 MYO par
8 LOM con
4 PAN jas 6 DIE gra 5 CAL ros 105.8m
4 SYZ bea
106.6m 1 ELA eum
8 ALP cae
4 MEL mal
2 DIE gra
4 SYZ sup 12 LIR str
5 ALP zer
1 CUP ana
OPERATIONAL WORKS
15 WES fru
NOT FOR CONSTRUCTION
50 DIA lit CHECKED : ……...………………………………….
5 SYZ sup 15 WES fru
5 MYO bon
106.8m GARDEN EDGE TO DETAIL 1 ELA eum 50 DIA lit 1 CUP ana
EXISTING TREES TO BE
RETAINED &
PROTECTED FROM A R CHIT E CT UR E | L A NDS CA P E | INT E R IOR | P ROJECT MA NA G E ME NT
DAMATE
EXISTING TREES TO BE 37 Aerodrome Rd Maroochydore Qld
RETAINED &
P.O. Box 154 Cotton Tree QLD 4558 phone 07 5443 3200
PROTECTED FROM 106.0m
DAMATE email [email protected] fax 07 5443 4030
107.0m project:
MAKE GOOD ANY MAKE GOOD ANY
DAMAGE TO EXISTING
NEW FOOTPATH DAMAGE TO EXISTING PROPOSED TOWNHOUSE DEVELOPMENT,
TURF TURF
106.2m 54 ELM ST. & 5 PEARL ST. COOROY
107.2m
client:
ALTUM
title:
LANDSCAPE PLANTING
LANDSCAPE PLANTING PLAN PLAN
01
106.4m
-
LEVEL 1 SCALE 1:100
north date: SEP 2023
drawn: BM
P E A R L S T R E E T checked: GC
scale @ A1 : 1:100
scale @ A3 : 1:200
10
10
10
10
10
10
7.6
7.4
7.2
7.0
6.8
6.6
project/drawing no. sheet: A1
m
m
m
m
m
m
7283_L03-01_G
GSPublisherVersion 1510.0.59.0
7283-26-Cooroy.pln printed: Thursday, 16 May 2024 1:54 pm
Page 3
notes :
1 The designs, drawings and specification are copyright and always
remain the property of Blackburne Jackson Design Pty Ltd.
EVENLY DISTRIBUTED MIXED REED PLANTING 2 Before commencing construction:
TO BIO-RETENTION BASIN INCLUDING: STONE PITCHED -Verify all dimensions and levels.
3 ALP cae 1 ELA obo
107.4m
1 FLI sch 1 CRI ped - 30 FIC nod
107.2m
2 MEL qui STORMWATER -Verify location and levels of all services on site.
10 DIA lit 4 MYO par STONE PITCHED STORMWATER - 30 JUN usi SPREADER -Verify that floor levels and finished levels will enable connection to
6 ALP cae 4 ACM sub 3 DOR exc 4 BAN rob 1 STE sin 1 FLI sch
107.0m
106.8m
106.6m
106.4m
106.2m
106.0m
105.8m
105.6m
105.4m
SWALE DRAIN - 30 LOM hys services.
1 STE sin 1 DOR exc 10 COM con
10 CAR des 30 LOM hys BIORETENTION BASIN OVERFLOW HEADWALL
4 MEL cal
4 SYZ bus 14 DIE gra TO CIVIL ENGINEER'S 3 Do not scale this drawing. When in doubt refer to Architects.
DETAIL
issue amendment log by date
A OPERATIONAL WORKS ISSUE KM 04-10-23
2 ALP cae B OPERATIONAL WORKS ISSUE NQ 14-11-23
C OPERATIONAL WORKS ISSUE NQ 05-12-23
3 MYO par
D OPERATIONAL WORKS ISSUE NQ 19-12-23
5 MYO par 5 HAR mee E OPERATIONAL WORKS ISSUE NQ 13-03-24
5 WES mun
8 LOM con 1 BAC cit F OPERATIONAL WORKS ISSUE NQ 19-03-24
8 LOM lim 2 COR pin 2 CRI ped
G OPERATIONAL WORKS ISSUE NQ 16-05-24
2 CRI ped
MAKE GOOD
ANY DAMAGE 10 MOL cap 12 SYZ sup
TO EXISTING
TURF
EXISTING FOOTPATH
STEPPER ACCESS PATH WITH GARDEN EDGE TO DETAIL
GRAVEL SURROUNDS TO DETAIL
STEPPER ACCESS PATH WITH STEPPER ACCESS PATH WITH
GARDEN EDGE TO DETAIL GRAVEL SURROUNDS TO DETAIL GRAVEL SURROUNDS TO DETAIL
6 RHA exc GARDEN EDGE TO DETAIL
S T R E E T
2x 8kL RAINWATER
20 HAR mee
TANKS OUTSIDE
COURTYARD
13 CAL ros
GATE consultants:
8 ACM sub 1 ELA obo STRUCTURAL ENGINEER :
14 MOL cap [company name]
PH : [number] [@email here]
GATE
CIVIL ENGINEER :
GATE 10 LIR str [company name]
2 CUP ana
PH : [number] [@email here]
GATE
4 DIA cae
01 02 03 04 05 06 07 08 HYDRAULIC ENGINEER :
[company name]
PH : [number] [@email here]
10 DIA cae ELECTRICAL & MECHANICAL ENGINEER :
E L M
8kL RAINWATER TANK
ON BODY CORP [company name]
PH : [number] [@email here]
MANAGED ZONE
6 ALP zer
18 DIA lit
6 ALP zer 20 DIA cae
105.4m
7 WES mun 8 ACM red
2 HYM lit 2 HYM lit
EXISTING TREES 4 SYZ sup 10 DIA cae 12 DIA lit 3 ZAM fur 12 DIA lit 3 ZAM fur
1 MYO bon 1 MYO bon
TO BE RETAINED
& PROTECTED
FROM DAMATE
6 MYO bon
4 LOM lim REFER 7883_L03-01 FOR CONTINUATION
8kL RAINWATER TANK
ON BODY CORP
1 ELA obo
MANAGED ZONE
8 SYZ sup 6 LOM lon 8 CAL sli 6 LOM lon 8 SYZ sup 10 LOM lon
6 DIA lit 6 DIA lit
107.6m
4 PAN jas
107.4m
107.2m
107.0m
106.8m
106.6m
106.4m
106.2m
8kL RAINWATER TANK
ON BODY CORP
MANAGED ZONE
6 ALP cae
106.2m
10 LOM lon 3 MOL cap GATE
4 PAN jas 9 MEL mal
105.6m
09 10 11 12
OPERATIONAL WORKS
10 DIA cae
2 ELA eum
8 PHO gla
4 PAN jas NOT FOR CONSTRUCTION
8 ALP cae
CHECKED : ……...………………………………….
12 MYO bon
10 LOM lon
24 DIA cae
A R CHIT E CT UR E | L A NDS CA P E | INT E R IOR | P ROJECT MA NA G E ME NT
STEPPER ACCESS PATH WITH 37 Aerodrome Rd Maroochydore Qld
106.4m GRAVEL SURROUNDS TO DETAIL STEPPER ACCESS PATH WITH
GRAVEL SURROUNDS TO DETAIL P.O. Box 154 Cotton Tree QLD 4558 phone 07 5443 3200
4 PAN jas GARDEN EDGE TO DETAIL email [email protected] fax 07 5443 4030
GARDEN EDGE TO DETAIL
project:
10 DIA cae
PROPOSED TOWNHOUSE DEVELOPMENT,
54 ELM ST. & 5 PEARL ST. COOROY
GATE
client:
8 DIE gra 7 PHO gla
4 MYO bon 8 LOM con
4 MYO par ALTUM
4 PAN jas 6 DIE gra 5 CAL ros 105.8m
4 SYZ bea
106.6m 1 ELA eum
title:
4 MEL mal
8 ALP cae
LANDSCAPE PLANTING
LANDSCAPE PLANTING PLAN
2 DIE gra PLAN
01 4 SYZ sup 12 LIR str
-
LEVEL 1 SCALE 1:100 5 ALP zer north date: SEP 2023
1 CUP ana
drawn: BM
checked: GC
15 WES fru scale @ A1 : 1:100
scale @ A3 : 1:200
50 DIA lit 5 SYZ sup 15 WES fru
5 MYO bon project/drawing no. sheet: A1
106.8m
7283_L03-02_G
GARDEN EDGE TO DETAIL 1 ELA eum 50 DIA lit 1 CUP ana
GSPublisherVersion 1510.0.59.0
EXISTING TREES TO BE 7283-26-Cooroy.pln printed: Thursday, 16 May 2024 1:54 pm
RETAINED &
PROTECTED FROM
DAMATE
Page 4
notes :
HESSIAN 1 The designs, drawings and specification are copyright and always
BOUNDARY
50mm WIDE SIZE STAKES ANGLE CUT POST TOPS
REFER TO PLAN VIEW FOR remain the property of Blackburne Jackson Design Pty Ltd.
2200 CTRS MAX.
N 45 litre 50x50mm POST SIZINGS
27
2 Before commencing construction:
100mm DEEP MULCH AS SPECIFIED. -Verify all dimensions and levels.
STAKE AS 100 litre 75x75mm 15 TYPICAL
PLANT AS FORM SHALLOW DISH DRAIN TO 75 x 50mm F14 ACQ TREATED -Verify location and levels of all services on site.
SPECIFIED
SPECIFIED BASE OF PLANT TO ENSURE MULCH HARDWOOD RAIL
25
200 litre 100x100mm -Verify that floor levels and finished levels will enable connection to
IS NOT IN CONTACT WITH PLANT CLASS 2 H3. services.
W E STEM
3 Do not scale this drawing. When in doubt refer to Architects.
300mm TOPSOIL AS PER NOTES. ADD 100 x 25mm F14 ACQ
WATER CRYSTALS AND SLOW TREATED HWD FASCIA issue amendment log by date
RELEASE FERTILISER AS PER CLASS 2 H3 NAILED TO
TREE MANUFACTURERS SPECIFICATIONS. 75 x 50mm F14 ACQ HWD RAILS. A OPERATIONAL WORKS ISSUE KM 04-10-23
S REFER TO TABLE FOR STAKE SIZES. PALINGS/RAIL CLASS 2 H3 OVERLAPPED AT B OPERATIONAL WORKS ISSUE NQ 14-11-23
STAKES TO BE F14 HARDWOOD NON- CORNER POSTS AS SHOWN
TREATED STAKES FREE FROM KNOTS 150mm CULTIVATED SUB-SOIL C OPERATIONAL WORKS ISSUE NQ 05-12-23
& WARPS ETC. 19 D OPERATIONAL WORKS ISSUE NQ 19-12-23
100 x 25mm F14 ACQ
2200 CTRS MAX.
STAKES TO BE DRIVEN IN TO A 100 x 100mm F14 ACQ HWD END
HEIGHT TO ENSURE STAKE DOES NOT TREATED HARDWOOD FASCIA E OPERATIONAL WORKS ISSUE NQ 13-03-24
MULCH : CLASS 2 H3 NAILED TO POST. CLASS 1 H5 SEASONED
DAMAGE LOWER LATERAL LIMBS. F OPERATIONAL WORKS ISSUE NQ 19-03-24
STAKES TO BE CENTRALLY POINTED MULCH GARDENS TO A MIN DEPTH OF PALINGS AND RAIL
& DRIVEN VERTICALLY INTO GROUND 100mm WITH HOOP PINE BARK (CHIP G OPERATIONAL WORKS ISSUE NQ 16-05-24
NOTES:
OUTSIDE OF ROOTBALL, TO BE SIZE 10-25mm) FROM MATURE TREES, NEIGHBOURING SITE
LOCATED IN NE & SW CORNERS FREE FROM WOOD SILVERS. DO NOT PROPERTY 15 x 100mm H4 ACQ HWD PALINGS
ROOT BARRIER TO BE APPLIED
MOUND MULCH HARD UP AGAINST NAILED TO PALINGS/RAILS
UNLESS OTHERWISE SPECIFIED
PLANT STEMS. 15 x 100mm H4 ACQ HWD M10 CUPHEAD BOLTS.
PALINGS NAILED TO COUNTERSINK BOLT AS SHOWN.
INSTALL SOCKED AG-PIPE IN GRAVEL
50mm WIDE HESSIAN SECURED PALINGS/RAILS
SURROUND FOR DRAINAGE TO
PERIMETER OF BASE CONNECTED TO LOOSELY TO TREE & FIXED TO STAKE 75x100mm F14 ACQ HWD POST.
WITH FLATHEAD GALVANISED NAILS
DETAIL
STORMWATER AS REQUIRED CLASS 1 H5 SEASONED.
OR STAPLES HEIGHT OF HESSIAN TIE
TO BE ONE THIRD TO ONE HALF OF 02 NOTE: END POSTS TO BE
100X100mm.
DO NOT AUGER ROUND PLANTING OVERALL HEIGHT OF TREE SCALE 1:10
HOLES, HOLES TO BE SQUARE IN
-
SHRUB & GROUNDCOVER PLANTING IN GROUND
PROFILE TO AVOID ROOT GIRDLING 75 x 50mm F14 ACQ TREATED 100x25mm F14 ACQ TREATED HWD
MOUND MULCH AT EDGE OF PIT TO HARDWOOD RAIL FASCIA CLASS 2 H3 NAILED TO
COLLECT WATER TO FALL DOWN
CLASS 2 H3. PALINGS
EDGES OF TREE PIT
TUBESTOCK AS SPECIFIED
100
100mm MULCH AS SPECIFIED
PLAN VIEW (WITH CORNER)
100
LOCALISED LOWERING OF SOIL
WHERE PLANTING OCCURS TO 50
100
ENSURE WATER RUN OFF TO
PLANTING AREAS consultants:
ROOTBALL DEPTH
TREE PIT TO BE EXCAVATED TO
STRUCTURAL ENGINEER :
DEPTH OF ROOTBALL BACKFILLED JUTEMASTER TM PEGGED SECURELY [company name]
WITH FRIABLE IMPORTED TOPSOIL FENCE ON RETAINING WALL NOTES
VARIES
WITH 100 x 100mm CROSS CUT FOR PH : [number] [@email here]
(50%), MIXED WITH SITE SOIL (50%) PLANT FOOTINGS TO BE 20 MPa NO
MAX 2% ORGANIC CONTENT FIRMING - REFER CIVIL ENGINEERING DETAILS. CIVIL ENGINEER :
FINES CONCRETE - POSTS TO BE BOLTED TO RETAINING WALL POSTS, 100 x 75mm
PROGRESSIVELY [company name]
300 x 300 x 600mm WITH - RETAINING WALL POSTS TO BE 100 x 200mm PH : [number] [@email here]
125mm COARSE DRAINAGE - ALIGN 200mm WIDE FACE OF RETAINING WALL POST PARALLEL TO FACE OF HYDRAULIC ENGINEER :
LOCALISE TOPSOIL AROUND PLANTS GRAVEL UNDER RETAINING WALL TO ENSURE THAT FENCE POST IS FLUSH ON FRONT FACE [company name]
APPROX. 3x TIMES THE VOLUME OF
600
TO RETAINING WALL POST. PH : [number] [@email here]
ADD WATER CRYSTALS AND SLOW THE ROOT BALL.
RELEASE FERTILISER AS PER ELECTRICAL & MECHANICAL ENGINEER :
150
MANUFACTURERS SPECIFICATIONS. FENCE NOTES [company name]
PH : [number] [@email here]
- MAX HEIGHT OF FENCE TO BE 1800mm
- FENCE TO HAVE 3 RAILS, INTERMEDIATE RAIL TO BE CENTRED BETWEEN
TOP AND BOTTOM RAIL.
ENSURE EDGES OF PIT ARE POROUS. - FIXINGS TO BE HOT DIPPED GALVANISED UNLESS WITHIN 1KM OF THE
RIP CLAY SOILS IF REQUIRED 150mm CULTIVATED SUB-SOIL COAST WHERE FIXINGS SHALL BE 316 STAINLESS STEEL.
- WHERE FIXINGS ARE LIKELY TO SPLIT TIMBER, PRE-DRILL TO 80% OF FIXING
DIAMETER.
125
1200 x1200mm SQUARE HOLE - ALL EXPOSED EDGES OF TIMBER TO BE ARISED.
(Minimum 2x width of rootball) - TIMBER FINSHES AS SPECIFIED.
03 DETAIL - ALL WORK TO BE PERFORMED IN ACCORDANCE WITH RELEVANT
DETAIL
AUSTRALIAN STANDARDS.
01 -
BIORETENTION TUBESOCK PLANTING
SCALE 1:10
300
- CONTRACTOR TO BUTT JOIN RAILS WITH BATTEN SCREWS IF
RECOMMENDED TECHNIQUE IS DISMISSED WITH AGREEMENT BY
SCALE 1:10
-
TREE PLANTING IN GROUND SECTION ARCHITECT.
100 x 25 TIMBER EDGING TO BE FLUSH 07 DETAIL
PLANTING AS PER WITH TOP OF TURF AND MULCH AS SCALE 1:10
PLANTING PLAN PER LANDSCAPE SPECIFICATION
-
TIMBER PALING FENCE IN GROUND
NOTES
BOUNDARY
BOUNDARY
TURF OR GRAVEL AS PER NOTES ANGLE CUT POST TOPS
REFER TO PLAN VIEW FOR
POST SIZINGS
27
ANGLE CUT POST TOPS
75 x 50mm F14 ACQ TREATED REFER TO PLAN VIEW FOR
POST SIZINGS
27
HARDWOOD RAIL
25
CLASS 2 H3.
75 x 50mm F14 ACQ TREATED
HARDWOOD RAIL
25
100 x 25mm F14 ACQ CLASS 2 H3.
TREATED HWD FASCIA
COMPACT EARTH BEARING STRIP CLASS 2 H3 NAILED TO
UNDER GARDEN EDGE PALINGS/RAIL 100 x 25mm F14 ACQ
TREATED HWD FASCIA nom 50x50mm SHS
NEIGHBOURING POWDERCOATED
CLASS 2 H3 NAILED TO
BOUNDARY
PROPERTY ALUMINIUM
19 100 x 25mm F14 ACQ PALINGS/RAIL
04 DETAIL TREATED HARDWOOD FASCIA
CLASS 2 H3 NAILED TO
SITE
SUPPORT FRAME
SCALE 1:10 19
-
TIMBER EDGING PALINGS AND RAIL 100 x 25mm F14 ACQ
TREATED HARDWOOD FASCIA
NEIGHBOURING SITE CLASS 2 H3 NAILED TO
PROPERTY PALINGS AND RAIL
NOM. 40mm THICK 15 x 100mm H4 ACQ HWD 75 x 50mm F14 ACQ TREATED
STONE STEPPERS LIGHTLY COMPACTED
PALINGS NAILED TO HARDWOOD RAIL
DECOMPOSED GRANITE (DECO)
PALINGS/RAILS CLASS 2 H3.
BEDDING SAND LAYER SITE
GEOFABRIC/WEEDMAT LAYER 15 x 100mm H4 ACQ HWD
ROAD VERGE
BELOW ALL DECO PALINGS NAILED TO
PALINGS/RAILS
nom. 35x35mm
75 x 50mm F14 ACQ TREATED POWDERCOATED
HARDWOOD RAIL ALUMINIUM
OPERATIONAL WORKS
CLASS 2 H3. VERTICAL BATTENS @
NOM. 200 80mm CTRS
GALVANISED FIXING BRACKET
TO STRUCTURAL ENGINEER'S FILL POWDERCOATED NOT FOR CONSTRUCTION
SPECIFICATION ALUMINIUM
100
SUPPORT POSTS
05 DETAIL FIXED TO TOP OF
BLOCK WALL
CHECKED : ……...………………………………….
SCALE 1:10 50 50 300 50
-
PRECAST CONCRETE STEPPER
100
FIXING TO
STRUCTURAL
ENGINEER'S
100 x 25 TIMBER EDGING LIGHTLY COMPACTED NOM. 40mm THICK SPECIFICATION
A R CHIT E CT UR E | L A NDS CA P E | INT E R IOR | P ROJECT MA NA G E ME NT
DECOMPOSED GRANITE (DECO) STONE STEPPERS 50
37 Aerodrome Rd Maroochydore Qld
FILL TO CREATE P.O. Box 154 Cotton Tree QLD 4558 phone 07 5443 3200
LEVEL YARD email [email protected] fax 07 5443 4030
600
FOOTINGS TO BE 20 MPa NO project:
FINES CONCRETE
300 x 300 x 600mm WITH PROPOSED TOWNHOUSE DEVELOPMENT,
125mm COARSE DRAINAGE
GRAVEL UNDER 54 ELM ST. & 5 PEARL ST. COOROY
FILL
NOM. 200 client:
125
ALTUM
title:
LANDSCAPE DETAILS
north date: SEP 2023
drawn: BM
LINE OF CONCRETE SLAB
08 DETAIL 09 DETAIL 10 DETAIL checked: GC
SCALE 1:10 SCALE 1:10 SCALE 1:10
OF TERRACE OR BUILDING -
TIMBER PALING FENCE ON BLOCK WALL -
TIMBER PALING FENCE BESIDE BLOCK WALL -
ALUMINIUM SCREEN ON BLOCK WALL scale @ A1 : 1:10
WHERE APPLICABLE
scale @ A3 : 1:20
06 DETAIL project/drawing no. sheet: A1
7283_L07-01_G
SCALE 1:10
-
PRECAST CONCRETE STEPPER - PLAN
GSPublisherVersion 1510.0.59.0
7283-26-Cooroy.pln printed: Thursday, 16 May 2024 1:54 pm