Appendix C Code Assessment Report -124 Eumundi Noosa Road, Noosaville - Noosa Pots + Plants · MCU18/0117
Attached to the e-mail Industrial Business Type 1 Warehouse & Retail Business Type 7 Garden Centre - MCU18/0117.
Business Uses Code
The proposed hostel development has been assessed against the relevant Specific Outcomes and Probable Solutions prescribed within Table 14.8 of the
Business Uses Code.
Specific Outcomes Probable Solutions Proposed Development
14.16 Effects of use
Electricity infrastructure S18.1 No solution provided Complies
O18 The development does not adversely impact on existing or The proposal will not negatively impact
future electricity supply infrastructure; AND upon Council’s existing infrastructure. The
proposal includes the reuse of an existing
industrial building.
O19 All uses and works maintain an adequate safe distance from S19.1 Development for uses adjacent to or within Not Applicable
electrical infrastructure including substations, overhead powerlines, 50m of an existing electricity substation No external alteration is proposed to the
power poles and transformers. incorporates noise attenuation measures to built form.
mitigate noise impacts; AND
S19.2 Buildings and structures (including Not Applicable
swimming pools, sheds, tennis courts and No external alteration is proposed to the
outbuildings) are not constructed under built form.
overhead electricity transmission lines, or within
electricity easements
Noise No solution provided. Complies
O20 Development is designed and sited to avoid noise emissions The proposed industrial warehouse and
that unreasonably diminish the amenity of the area or surrounding garden centre is located on a site that is
uses appropriate for the use and is consistent
with surrounding uses. The proposed use is
unlikely to have any adverse impacts on the
adjoining uses and natural environment,
and is compatible with the existing
surrounding uses.
Mechanical plant and equipment and storage areas S21.1 Mechanical plant and equipment are— Complies
O21 Mechanical plant and equipment (including air conditioning a) located more than 2m from any property No additional mechanical plant or
equipment) and storage areas are designed and located to— boundary; b) where located at ground level, equipment is proposed. All stock will be
14-16 Mary Street, Noosaville 16
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix C Code Assessment Report -124 Eumundi Noosa Road, Noosaville - Noosa Pots + Plants.pdfRelated documentApplication case desk ↗
About this file
- File size
- 480 KB (small file)
- File type
No other editions are linked here.