Council archive · source document
Appendix C Code Assessment Report -124 Eumundi Noosa Road, Noosaville - Noosa Pots + Plants · MCU18/0117
Attached to the e-mail Industrial Business Type 1 Warehouse & Retail Business Type 7 Garden Centre - MCU18/0117.
provided that the gross floor area does not exceed 13,600m2 . Zone.
O15 For the Business Centre Zone, outside of the Mary Street/Thomas No solution provided Not Applicable
Street Precinct the maximum plot ratio is — The subject site is located in the Industrial
a) 0.8:1 for site areas up to and including 2,000m2 ; plus Zone.
b) 0.3:1 for the balance portion of the site area in excess of 2000m2.
O16 For the Shire Business Centre Zone, the maximum plot ratio for No solution provided Not Applicable
development within the following precincts is — The subject site is located in the Industrial
a) Precincts B1 and B2 combined- 0.5:1; Zone.
b) Precinct B3- 0.8;
c) Precinct E1- 0.6;
d) Precinct E2- 0.6;
e) Precinct E3- 0.6, except for Industrial business uses;
f) Precinct E4- 0.6; except for Industrial business uses;
g) Precinct E5- 0.6, except for Industrial business uses;
h) Precinct E6- 0.6;
i) Precinct E7- 0.6;
j) Precinct RES- 0.6; and
k) Precinct REC/MU- 0.1.
Flooding and drainage S17.1 For new buildings or structures or Not Applicable
O17 Buildings and other works are designed and sited to— additions of more than 50m2 gross floor area The proposal includes the reuse of an
a) provide flood free access to premises and flood free habitable areas; to an existing building or structure, floor existing building and does not include the
b) allow only minor, short term and infrequent flooding of non- levels for habitable rooms are not less than addition of more than 50m2.
habitable areas; the specified minimum floor levels; AND
c) ensure carparking areas can be adequately drained; S17.2 Where Council infrastructure is Complies
d) ensure drainage does not adversely impact upon other premises; and available— The existing building is connected to
e) ensure filling or excavation does not adversely impact upon other a) any drainage (including buildings and Council’s existing infrastructure.
premises by— yards) flows to that infrastructure; and
i. causing ponding on the site or nearby land; b) the infrastructure has the capacity to
accept any additional loading; AND
ii. increasing flooding, which adversely affects the safety or use of S17.3 For Residential Uses— Not Applicable
any land upstream and downstream; and a) where slab on ground construction is used, The proposal is for an industrial and retail
filling does not extend more than 1m beyond use within the Noosaville Industrial
iii. adversely affecting the flow of water in any overland flow path. the building footprint and access to car Precinct. The proposal includes the reuse of
parking areas, measured from the outer walls an existing building.
of the building; or
b) the design consists of a suspended floor
14-16 Mary Street, Noosaville 8
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix C Code Assessment Report -124 Eumundi Noosa Road, Noosaville - Noosa Pots + Plants.pdfRelated documentApplication case desk ↗
About this file
- File size
- 480 KB (small file)