Original source · versioned page text
RECOR RFI Response
Attached to the e-mail Response to RFI - 9 Bottlebrush Avenue Noosa Heads - MCU21/0133.
28th September 2021
Ref: MCU21/0133 & OPW21/0220
Noosa Council
PO Box 141
TEWANTIN QLD 4565
Attention: Patrick Murphy
Dear Sir,
Re: Information Request
At: 9 Bottlebrush Ave, Noosa Heads, QLD 4567
With reference to the abovementioned information request for the development
application (ref: MCU21/0133 & OPW21/0220), we have prepared an update to the
engineering aspects of the submission to address the issues raised in the Request for
Information as follows:
1. Provide amended plans that include:
1.1. The longitudinal section extending to the centreline of the road formation
1.2. The plans with the footpath section located where pedestrians could
reasonably cross to the existing path in the frontage of the adjoining property
1.3. The footpath section with a consistent width on the relevant plans (desirably
2m, 1.5m minimum)
1.4. Additional sections within the road reserve which clearly indicate the transitions
to the adjacent verge areas which do not create trip or fall hazards.
Please note that Council does not support private retaining structures in the road
reserve
The longitudinal section has been extended to the centreline of the road formation, and
the grades have been updated to provide for a 1.5m path zone adjacent the kerb to align
to the existing footpath to the north. An additional section has been created showing the
transition to adjacent verge areas to demonstrate that no retaining structures are
necessary within the road reserve.
1.5. The depths of the existing services in the road reserve determined by
potholing. If it is apparent that services may need to be altered provided written
approval from the relevant service provider
We request that the requirement for potholing to locate the existing services be
conditioned to be required with pre-start works as part of the development approval
conditions.
2. Provide amended plans that demonstrate that all spaces are accessible for a B99 vehicle
to enter the space in a forward gear, reverse from the space and exit the site in a forward
gear in a total of 3 movements.
P +61 7 5211 1003 A 37 Mary St, Noosaville Qld 4566 E [email protected] recorconsulting.com