07/1409 - MCU - Domestic Marine [As Published] · 142007.1409
MAXIMUM RECORDED FLOOD LEVEL RL 2.00 AHD
Or mmm nL
1. UNLESS NOTED OTHERWISE, ALL CONSTRUCTION SHALL COMPLY
WITH THE AS 1084 - *ALUMINKJM STRUCTURES COOE™, AS10665 - “ALUMINIUM
ALL ALUMINIUM SECTIONS SHALL BE 6081/T6 ALLOY WITH 5086 OR 6083
ALLOY FOR PLATE:
MINIMUM WATER RL 0.44 AHD 3 ALL SUCH AS MIG OR NA.
as WELDING 6061 TO 6041, USE 4043 ALLOY FULLER.
WHEN USE 5368 ALLOY FILLER.
4. STAINLESS STEEL, WHERE NOMINATED, SHALL BE ALLOY 304 OR 318,
PILES:
ALL PILES SHALL BE APPROVED HARDWOOD
AND TREATED TO HAZARD 6.
ALL PILES SHALL BE INSTALLED IN ACCORDANCE
WITH AS 2159 - PILING CODE
MAXIMUM TOTAL
BOAT WEIGHT
2/916 & BOLTS $00 x 100 x 6.0
1500 kg 10mm WINCH fA
PLATE AT 16 100 x 100 x0
PLATE WELDED
TO 100 x 100 x 6.0 EA
2200 MIN TREATED
100 x 80 x 6.0
‘SECTION
APPROXPLETOPRIOS Ono's 88 AN ee = SECTION X- X
50 x 50 x 3.0 RHS e WELDED TO FRAME
APPROX PILE TOP RL 0.66 1:10
1:20
3300 1800
John Norden
& Associates
ACN 010 263 677
Ee
Suvawrel / Civ Design Eng.nsere
‘Sule 15 ‘Towanta Pieze*
Poncdana Avenus / PO Box 206
Tewentin O 4565
Pr: OF 54467137 Fac 07 54437172
een ie
FRAMING LAYOUT WORKING DRG
- — - - 07/134-3 |