Log in to see the plans as drawn SPECIFICATION NOTES · FINISHED TURF GRADES/CONTOURS TO BE GENERALLY SMOOTH, COORDINATE ON SITE WITH SUPERINTENDENT
AND ENSURE LEVELS ARE APPROVED PRIOR TO TURFING.
NOTE:THIS LANDSCAPE PLAN MUST BE READ IN CONJUNCTION WITH THE APPROPRIATE STATUTORY APPROVALS, · TURF LAID ON LOW SIDE OF HARD SURFACES SHALL BE 20MM BELOW ADJACENT HARD SURFACE TO NOT IMPEDE
SUNSHINE COAST COUNCIL REQUIREMENTS AND RELEVANT AUSTRALIAN STANDARDS. STORM WATER FLOW.
· SUPPLY AND LAY TURF AS INDICATED ON THE DRAWINGS.
THIS INCLUDES BUT IS NOT LIMITED TO: · WATER TURF IN WELL DURING ESTABLISHMENT.
AS3640 WORKPLACE ATMOSPHERES - DUST · APPLY WATER TO MAINTAIN SOIL MOISTURE UNTIL ESTABLISHED DURING MAINTENANCE PERIOD TO MAINTAIN
AS4373 PRUNING OF AMENITY TREES VIBRANT GREEN TURF COLOUR AND HEALTH.
AS4454 COMPOSTS, SOIL CONDITIONS & MULCHES
GRADES
· SITE SHALL BE POSITIVELY DRAINED, I.E. NO PONDING AREAS, 2% MINIMUM TO PITS OR LEGALLY SHEET FLOWING
GENERAL SUNSHINE COAST
· FOR MORE DETAIL REFER TO THE PROJECT ARCHITECT'S AND ENGINEER'S DRAWINGS. OFF-SITE.
· MULCHED GARDEN BED AREAS SHOULD NOT EXCEED A 1:3 GRADE AND TURF AREAS SHOULD NOT EXCEED A 1:4 Level 1, 24 Duporth Avenue
· PLANTING SHOWN REFLECTS THE DESIGN INTENT, EXACT NUMBERS AND LOCATIONS WILL REQUIRE CONFIRMATION GRADE. Maroochydore QLD 4558
ON SITE BY THE SUPERINTENDENT. ANY CHANGES TO BE MADE TO THE LANDSCAPE PLAN MUST BE APPROVED BY · FINAL GRADE EXISTING TOP 100MM AND TRIM TO +/-10MM TO ACHIEVE PLAN LEVELS. T + 61 7 5499 6188
THE LANDSCAPE ARCHITECT AND SUPERINTENDENT.
MAINTENANCE TASKS
· ALL LANDSCAPE PLANS PRESENTED ASSUME THAT ALL BASE AND SURVEY INFORMATION IS ACCURATE AND TO · LANDSCAPE CONSTRUCTION CONTRACTOR TO MAINTAIN WHOLE OF LANDSCAPE WORKS FOR ESTABLISHMENT
© Place Design Group Pty Ltd A.C.N. 082 370 063
SCALE. THE CONTRACTOR SHALL CHECK LANDSCAPE PLANS PRESENTED FOR ANY DISCREPANCIES WITH THE PERIOD OF 13 WEEKS AND HAND OVER TO OWNER ONCE COMPLETED.
EXISTING SITE CONDITIONS OR OTHER DRAWINGS PRESENTED PRIOR TO ANY CONSTRUCTION WORK TAKING PLACE. · THE FOLLOWING TASKS ARE TO BE ACTIONED DURING ESTABLISHMENT AND IN PERPETUITY; All information displayed, transmitted or carried within this drawing is
protected by Copyright and Intellectual Property laws.
IF DISCREPANCIES DO OCCUR THESE SHALL BE HIGHLIGHTED AT ONCE TO THE SUPERINTENDENT PRIOR TO ANY The information contained in this document is confidential.
CONSTRUCTION WORK TAKING PLACE. DIMENSIONS TAKE PRECEDENCE. IRRIGATION AND WATERING Recipients of this document are prohibited from disclosing the information
herein to any person without the written consent of Place Design Group.
· EVERY DAY FOR THE FIRST TWO WEEKS (UNLESS IT RAINS ADEQUATELY) Annotated dimensions take precedence over any measures of scale.
THE CONTRACTOR SHALL: · EVERY 2-3 DAYS DURING THE BALANCE OF THE ESTABLISHMENT PERIOD OR AS NEEDED IF HOT AND DRY (UNLESS IT Verify all dimensions on site prior to construction.
This drawing may display with permission a combination of specialist and
· INSTALL SILT CONTROL AND VEGETATION PROTECTION FENCING AS REQUIRED. RAINS ADEQUATELY). other consultant(s) input and linework.
REMOVE ALL UNWANTED MATERIAL FROM LANDSCAPE WORK AREA. · ONCE A WEEK THERE AFTER. . Nominated specialist and consultant information contained within this
APPROVED PLAN
· document is referenced from their supplied documentation and is
· CONFIRM ALL DIMENSIONS ON SITE PRIOR TO CONSTRUCTION. contained in this document as indicative only and not for construction or
TURF MOWING
RAL20/0017 & OPW20/0144
certification purposes.
· SEEK INSTRUCTION FROM SUPERINTENDENT WHERE LEVEL DISCREPANCIES, SPECIFICATION SUBSTITUTIONS AND
POOR SOIL STRUCTURE OCCURS. · FIRST MOW - ONCE AFTER 10 DAYS IF THERE IS RAPID GROWTH OR 14 DAYS AFTER INSTALLATION.
NOOSA COUNCIL
· MOWING THEREAFTER - ONCE A WEEK DURING SUMMER, ONCE EVERY TWO WEEKS IN SPRING AND AUTUMN, PROJECT
SERVICES AND ONCE A MONTH IN WINTER OR AS REQUIRED IF THERE IS A LOT OF GROWTH OR AS DESIRED.
· THE CONTRACTOR SHALL CONFIRM THE LOCATION OF ALL SERVICES WITH RELEVANT AUTHORITIES PRIOR TO 3 December 2020 LOT 1 TAYLOR CT, COOROY
PLANTING AND EXCAVATION. TURF TRIMMING .
· AS REQUIRED. MAINTAIN 5MM GAP BETWEEN TURF AND HARD SURFACES.
DRAINAGE
· ENSURE DRAINAGE WORKS CORRELATE WITH ADJACENT LAND AND SPECIFIED FINISHED LEVELS. TURF AERATION AND TOPDRESSING CLIENT
· INSTALL FIELD INLETS TO MANUFACTURER'S RECOMMENDATIONS AT LOCATIONS AND LEVELS INDICATED ON · AS REQUIRED - TYPICAL TIMING IS END OF OCTOBER (SPRING) AND END OF FEBRUARY (AUTUMN).
PLANS. FINISH SURFACE PIT LEVEL FLUSH WITH ADJACENT FINISHED SURFACE LEVELS. ENSURE POSITIVE OVERLAND · AERATE 100MM DEEP, 50MM O.C. WITH 16MM TINE (CORER).
DRAINAGE FLOW TO ALL PITS AND THAT NO PONDING OCCURS AROUND THE PIT. ALIGN ALL PITS SQUARE WITH TO · COLLECT PLUGS AND DISPOSE ENSURING THEY DO NOT GET REINCORPORATED INTO HOLES. TOPDRESS WITH TURF BULLGATE PTY LTD
PATHS, PAVEMENT PATTERNS, KERBS, WALLS AND ALIKE. TOPSOIL NOMINATED IN FINISHES SCHEDULE - BRUSH TOPSOIL IN WITH BROOM.
IF REQUIRED:
· INSTALL CONTINUOUS SUB-SURFACE DRAINAGE SYSTEM TO LOCATIONS AND LEVELS AS INDICATED ON PLANS. ADDITIONAL MAINTENANCE TASKS NOTES
SUB-SOIL DRAINS SHALL INCORPORATE A TRENCH WITH A GEOTEXTILE LINING, DRAINAGE GRAVEL BACKFILL · WEED REMOVAL AND WICK WIPING: AS REQUIRED TO REDUCE COMPETITION AND SEEDING.
ALL MEMBER SIZES, CONNECTIONS, FOOTINGS ETC
MATERIAL AND A 100MM SLOTTED AG-PIPE TO THE FOLLOWING SPECIFICATION; · PLANT REPLACEMENT: IMMEDIATELY REPLACE PLANTS THAT DIE OR FAIL TO THRIVE, ARE DAMAGED OR STOLEN, ARE TO BE CONFIRMED BY AN ENGINEER. SIZES
- GEOTEXTILE MATERIAL: GEOTEXTILE MATERIAL SHALL BE A NON-WOVEN TYPE WITH PLANTS OF THE SAME SPECIES AND OF SIMILAR SIZE AND QUALITY UNLESS OTHERWISE SPECIFIED. NOMINATED ARE INDICATIVE OF FINAL APPEARANCE
AND SHALL HAVE A STRENGTH RATING (G) OF GREATER THAN 900 · STAKES AND GUYS: ADJUST AND/OR REPLACE STAKES AND TIES WHERE REQUIRED. REMOVE STAKING AND GUYING REQUIRED. CONTRACTOR IS TO PROVIDE SHOP
- BACKFILL MATERIAL: 20MM DRAINAGE AGGREGATE IN ACCORDANCE WITH WHEN INSTRUCTED BY THE SUPERINTENDENT. DRAWINGS FOR APPROVAL BEFORE COMMENCING
· RE-MULCHING: AS REQUIRED TO MAINTAIN A CONSISTENT DEPTH, 100MM SETTLED, UNTIL PLANTS ARE CONSTRUCTION.
AS 2758 - 1988.
- DRAINAGE PIPES: 100MM Ø SLOTTED AG-PIPES SHALL COMPLY WITH ESTABLISHED. ALL WATER PROOF MEMBRANES, HYDRAULIC
AS 2439-PART 1 "PERFORATED DRAINAGE PIPE AND ASSOCIATED FITTINGS". · TRIM / PRUNE PLANTS TO REMOVE DEAD, DYING AND DISEASED GROWTH AND FOR CHARACTER AND FORM AS FITTINGS, ELECTRICAL / LIGHTING FITTINGS AND
PERFORATIONS SHALL NOT EXCEED 0.7MM IN DIAMETER OR WIDTH. REQUIRED. REINFORCED CONCRETE STRUCTURES ETC TO
· ENSURE PRUNING OF TREES TO DEVELOP ONE MAIN TRUNK & LOWER BRANCHES ARE REMOVED TO ALLOW SIGHT ENGINEERS, ARCHITECTS, HYDRAULIC ENGINEERS,
LINES FOR VEHICLES. ELECTRICAL ENGINEERS DETAILS AND
TOPSOIL SPECIFICATIONS.
· COLLECT TOPSOIL SAMPLE(S) AND HAVE IT TESTED BY A NATA CERTIFIED LAB FOR HORTICULTURAL SUITABILITY, I.E. SIZES NOMINATED ARE INDICATIVE OF FINAL
PLANTING TREES AND TURF. FURNISH TEST RESULTS TO LANDSCAPE ARCHITECT. MONITORING: PROVIDE A MONTHLY REPORT ON COMPLETED TASKS. APPEARANCE REQUIRED
· CULTIVATE GARDEN AND TURF AREAS 150MM DEEP.
· AMELIORATE SUBGRADE AND SITE TOPSOILS PER TESTING RESULTS. CERTIFICATIONS
· INSTALL AMELIORATED SITE TOPSOILS OR APPROVED IMPORTED TOPSOIL THAT COMPLIES WITH MRTS 16 (MAIN · PROVIDE AS2013:2105, TOPSOIL, MULCH, AND TURF CERTIFICATIONS TO SUPERINTENDENT AND LANDSCAPE
ROADS TECHNICAL SPECIFICATION) TO PLANTING AREAS IF AMELIORATED SITE TOPSOIL IS NOT AVAILABLE. ARCHITECT PRIOR TO PRACTICAL COMPLETION.
· ALL SOIL STOCKPILES ARE TO BE MAINTAINED TO CONTROL WEEDS ROUTINELY AND GUARD AGAINST DISPERSION
BY WIND OR WATER. STOCKPILES SHALL BE LIMITED TO A MAXIMUM HEIGHT OF 2M AND MAY REQUIRE COVERING DELIVERABLES
OR RETAINING. STOCKPILES ARE NOT PERMITTED WITHIN CLOSE PROXIMITY TO RESIDENTIAL PROPERTIES. · WARRANTIES
· GENERALLY SOIL TO BE USED SHALL COMPLY WITH THE FOLLOWING SPECIFICATION;
(1) FRIABLE AND FREE DRAINING SANDY LOAM SOURCES
(2) GOOD TEXTURE AND STRUCTURE FOR SELECTED USE · SURVEY - PROVIDED TO US BY BARLOW SHELLEY CONSULTING ENGINEER FOR APPROVAL
(3) ACCEPTABLE CONDUCTIVITY AND PH LEVELS FOR SPECIFIED PLANTS · CIVIL ENGINEERING - BARLOW SHELLEY CONSULTING ENGINEERS
CONCRETE
ISSUE CODE ISSUE DESCRIPTION BY CHK DATE
· REFER TO FINISHES SCHEDULE AND ENGINEER'S AND ARCHITECT'S PLANS RESPECTIVELY.
01 CA FOR OPERATIONAL WORKS VS JB 24.08.2020
02 CA OPERATIONAL WORKS RFI RY JB 13.10.2020
MULCH
· ALL MULCH PROPOSED TO BE USED ON SITE SHALL BE FREE OF DELETERIOUS MATERIALS AND FOREIGN MATTER
INCLUDING ANTHROPOGENIC WASTE, ROCK, SOIL, SEDIMENT CONTAMINATION, WEEDS AND STICKS.
· MULCH GARDEN AREAS 100MM DEEP SETTLED, KEEPING 50MM CLEAR OF PLANT STEMS, TO ENSURE SITE WATER
CONSERVATION REQUIREMENTS ARE ACHIEVED.
GENERAL PLANTING
· PLANT STOCK IS TO BE APPROVED BY CONTRACTOR AND QUALIFIED ARBORIST PRIOR TO ACCEPTANCE OF DELIVERY.
· FOR PLANTING, EXCAVATE GARDEN AREAS TO A DEPTH OF 300MM, CULTIVATE SUBGRADE TO A DEPTH OF 150MM
AND TREAT AS PER SOILS TESTING RESULTS.
· INSTALL AMELIORATED SITE TOPSOIL OR SPECIFIED TOPSOIL 300MM DEEP, SETTLED, AND MULCH AS SPECIFIED.
· NO SYNTHETIC, GRANULAR BLENDED FERTILISERS TO BE USED ON SITE. SLOW RELEASE ORGANIC TREE TABLETS
SHALL BE USED AT ESTABLISHMENT.
· ALL PLANTINGS SHALL INCORPORATE THE INCLUSION OF A SLOW RELEASE NATIVE PLANT FERTILIZER (AS PER
MANUFACTURERS SPECIFICATION) AND THE USE OF A SOIL MOISTURE RETENTION ADDITIVE (AS PER
MANUFACTURERS SPECIFICATION), PLACED ADJACENT THE PLANT ROOT BALL AT THE TIME OF PLANTING.
· TREES >25 LITRE BAGS ARE TO BE CERTIFIED BY A QUALIFIED ARBORIST AS AS2013:2105 COMPLIANT PRIOR TO
DELIVERY TO SITE. QUALIFIED ARBORIST TO SELECT AS2013:2105 COMPLIANT TREES AT NURSERY AND CHECK ON
DELIVERY TO SITE. FURNISH CERTIFICATION TO SUPERINTENDENT AND LANDSCAPE ARCHITECT PRIOR TO PRACTICAL PRE - Preliminary | CA - Council Approval | T - Tender | CON - Construction
COMPLETION.
· DO NOT INSTALL TREES WITHIN: DRAWING TITLE
- 1M OF UNDERGROUND SERVICES
- 1.5 OF SEWERS, HORIZONTALLY AND VERTICALLY GENERAL
- 3M OF DRIVEWAY CROSSOVERS
- 4M OF STREET LIGHTS AND POWER POLES SPECIFICATION
- 5M OF BUS STOPS - DEPARTURE SIDE
- 15M OF BUS STOPS - ARRIVAL SIDE
· WHERE DIFFERENT GROUNDCOVERS ARE PLANTED IN MASSES, TRIANGULARLY SPACE THEM EQUIDISTANT PER DESIGN : JB NORTH
SPECIES AND PLANT THEM IN ODD NUMBERED GROUPS OF 5, 7, AND 9 PER SPECIES DOCUMENT : VS
PROJECT : 2020057
TURF AREAS
· EXCAVATE TURF AREAS TO A DEPTH OF 150MM, CULTIVATE SUBGRADE TO A DEPTH OF 150MM AND TREAT AS PER
SOILS TESTING RESULTS.
· INSTALL 150MM OF AMELIORATED SITE TOPSOIL.
DRAWING NUMBER REVISION
2020057-LS-001 02
Document Set ID: 21311509
Version: 1, Version Date: 03/12/2020
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.