Council archive · source document
RAL20 0017 Approved Plans · MCU22/0003
Plans and drawings: the text below has words only, no drawings.
Very large file (16.2 MB): may take a few minutes to open.
Original PDF page 10, section 1. The text section number identifies this passage in the reader.
TREE AS SPECIFIED.
SUNSHINE COAST
WOVEN JUTE TREE TIE. Level 1, 24 Duporth Avenue
2 x 50 X 50 X 1800mm Maroochydore QLD 4558
HARDWOOD TIMBER STAKES, T + 61 7 5499 6188
TUBESTOCK PLANTING AS PAINTED BLACK IN COLOUR. TURF AS SPECIFIED TO BE LAID
SPECIFIED. WITH STAGGERED CLOSE BUTTED
POT DIA JOINTS SO THAT FINISHED TURF
ORGANIC MULCH AS SPECIFIED. SURFACE IS FLUSH WITH ADJACENT © Place Design Group Pty Ltd A.C.N. 082 370 063
100mm DEEP MULCH COLLAR
SURFACE LEVELS.
TAPERED DOWN IN CENTRE TO All information displayed, transmitted or carried within this drawing is
KEEP MIN. 50mm CLEAR OF POT DIA FORM WATERING BASIN.
EXISTING GROUND LINE. protected by Copyright and Intellectual Property laws.
PLANT STEM. The information contained in this document is confidential.
MULCH AS SPECIFIED. Recipients of this document are prohibited from disclosing the information
600mmX600mm BIODEGRADABLE JUTE herein to any person without the written consent of Place Design Group.
WEED CONTROL MAT. TYPE "TREE MAX SLOW RELEASE FERTILISER. TOPSIOL AS SPECIFIED. Annotated dimensions take precedence over any measures of scale.
Verify all dimensions on site prior to construction.
MAX-MAT2" OR APPROVED SIMILAR.
This drawing may display with permission a combination of specialist and
other consultant(s) input and linework.
TOPSOIL AS SPECIFIED. Nominated specialist and consultant information contained within this
SCARIFY ALL SIDES OF
EXISTING SUBGRADE. document is referenced from their supplied documentation and is
PLANTING PIT.
EXISTING SUBGRADE. contained in this document as indicative only and not for construction or
GARDEN SOIL AS SPECIFIED. certification purposes.
TOPSOIL AS SPECIFIED.
PROJECT
EXISTING SUBGRADE. CULTIVATE SUBGRADE TO
MIN. 150mm DEPTH.
LOT 1 TAYLOR CT, COOROY
3 x TUBE SIZE
CLIENT
01 TYPICAL TUBESTOCK PLANTING DETAIL 02 TYPICAL STREET TREE PLANTING DETAIL 03 TYPICAL TURF DETAIL BULLGATE PTY LTD
SCALE 1:10 SCALE 1:20 SCALE 1:20
NOTES
ALL MEMBER SIZES, CONNECTIONS, FOOTINGS ETC
ARE TO BE CONFIRMED BY AN ENGINEER. SIZES
TPZ Crown TPZ NOMINATED ARE INDICATIVE OF FINAL APPEARANCE
REQUIRED. CONTRACTOR IS TO PROVIDE SHOP
DRAWINGS FOR APPROVAL BEFORE COMMENCING
.
Determining TPZ (Tree Protection Zone) Radius
APPROVED PLAN
Vegetation to be protected CONSTRUCTION.
· DBH (Diameter at Breast Height) = Nominal
ALL WATER PROOF MEMBRANES, HYDRAULIC
Trunk Diameter at 1.4m above ground
level
RAL20/0017 & OPW20/0144 FITTINGS, ELECTRICAL / LIGHTING FITTINGS AND
REINFORCED CONCRETE STRUCTURES ETC TO
· TPZ should not be less than 2m nor greater NOOSA COUNCIL ENGINEERS, ARCHITECTS, HYDRAULIC ENGINEERS,
ELECTRICAL ENGINEERS DETAILS AND
than 15m except where crown protection
is required 3 December 2020 SPECIFICATIONS.
.
SIZES NOMINATED ARE INDICATIVE OF FINAL
· TPZ = DBH x 12 APPEARANCE REQUIRED
· TPZs of palms, other monocots, cycads and
tree ferns should be 1m minimum
· Variations and encroachments into the TPZ
shall be in accordance with AS 4970-2009
FOR APPROVAL
ISSUE CODE ISSUE DESCRIPTION BY CHK DATE
01 CA FOR OPERATIONAL WORKS VS JB 24.08.2020
02 CA OPERATIONAL WORKS RFI RY JB 13.10.2020
Star picket with Yellow
Plastic Caps, typical
Fluorescent orange 5.5kg REFER TO DETAILS FOR SHRUB BEDS
barrier fencing with mesh AND PLANS FOR TREE / SHRUB TYPES
Tree Protection Fencing, secured / tied 100mm AND LOCATIONS
75
typical below top of star pickets TURF AS PER SPECIFICATION
and at 300mm centres
Measurement Taken for DBH 1.2m
1.4`m CULTIVATED SUBGRADE
EXISTING SUBGRADE
Ground Level PRE - Preliminary | CA - Council Approval | T - Tender | CON - Construction
NOTE: GARDEN EDGES TO BE DRAWING TITLE
DBH INSTALLED TO ALL JUNCTIONS
Notes 600mm
· Protective fencing shall be installed around the TPZ before construction begins BETWEEN PLANTED AREAS AND
· Fence posts and supports shall be greater than 20mmØ located clear of roots TURF. REFER TO PLANS FOR TYPES SOFTSCAPE DETAILS
· Protective fencing identifying the TPZ shall be visibly signed within the development site.
Signage lettering to comply with AS 1319.
· Where tree protection fencing cannot be installed, install protection measures for trunk, branch and ground as specified DESIGN : JB NORTH
· by the project arborist as per AS 4790-2009
DOCUMENT : VS
· For disturbed land, install organic composted mulch free of deleterious materials 50-150mm deep settled within TPZs
· TPZ maintenance to include regular soil moisture monitoring and weed removal by hand. Control weeds with a PROJECT : 2020057
04 TREE PROTECTION 05 SPADE GARDEN EDGE
SCALE 1:25 SCALE 1:25
DRAWING NUMBER REVISION
2020057-LS-901 02
Document Set ID: 21311509
Version: 1, Version Date: 03/12/2020
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.