Original source · versioned page text
M2915 - Information Request Response
. Response The Site Based Stormwater Management Plan (Refer to Attachment C) provides further details regarding the historical point of discharge and legal point of discharge. As outlined in Item 5 above, the revised proposal involves an on-site infiltration tank system with sufficient capacity to manage stormwater flows and ensure non-worsening of drainage impacts, prior to discharge from the site... Item 7 – Infrastructure clearances Provide a sectional plan that clearly demonstrates that suitable vertical clearances can be provided between the proposed stormwater line and the existing sewer main Response The required vertical clearances between the existing sewer main and stormwater infrastructure are illustrated in the revised engineering plans included as part of the Site Based Stormwater Management Plan (Refer to Attachment C). Item 8 – Carpark access Provide additional detail on how the proposal addresses the potential for conflict at the end of the access driveway between vehicles entering and exiting the carparking area. Response The carpark area has been amended to reduce potential traffic conflicts by relocating the designated shared PWD space /turning bay, so that it can now be utilised should a vehicle being exiting the carpark at the same time as another vehicle is entering. Suitable visibility is available to ensure both vehicles can safely negotiate a passing manoeuvre (Refer to Attachment D). It is also noted that the scale of the development is small and the proposed uses will not result in a high vehicle turnover in the carpark area. As a result, any conflicts arising from vehicle exiting and entering the carpark are anticipated to be low and manageable. Item 9 – Turning templates Provide a plan of the swept paths for vehicles exiting the carparking area and travelling along the access driveway. Response: Turning templates have been prepared by Bax Engineering (Refer to Attachment D), which demonstrate the turning manoeuvres required to access each car space in the proposed car parking area. The plans demonstrate that the turning areas are appropriate for a small-scale development, with low vehicle turnover. Item 10 – Suitability of the turf cells Provide additional detail that demonstrates that the proposed grass cells are suitable for the intended use and are not impacted by vehicles using the driveway JFP Ref: M2915P Page 5
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.