2.1.3 Maximum Landscape Slope
The slope of the land is a major determinant of fire behaviour. Fire burns faster as it travels up a slope,
via the preheating of unburnt fuels ahead of the fire, increasing the rate of spread and fireline intensity.
Conversely, fires move more slowly as they travel downslope. Fireline intensity (kW/m) is a function of
the rate of spread. As a general rule, the rate of fire spread (and fireline intensity) doubles up a 10-degree
slope and quadruples up a 20-degree slope (QFES, 2019). The vegetation in proximity to the proposed
development area is located on flat ground or upslope/across slope with respect to the proposed
glamping tents. Where the slope under hazardous vegetation is located across slope, it is assessed as
being upslope irrespective of the slope of land between the site and the edge of the hazardous vegetation.
Note that for the purposes of undertaking a bushfire hazard assessment, where the topography is flat or
where vegetation is located upslope of an assessment site, a slope of 1 degree is required to be used to
satisfy the mathematical formula, however it has negligible impact on the calculations.

The VHC 9.1 Eucalypt forest located to the south of the proposed development area is located on steep
slopes of approximately 12 degrees.

2.1.4   Fire Danger Index
The Queensland government produce a publicly available data package which includes selected inputs
and information used by the CSIRO in conjunction with the QFES to prepare the State-wide Bushfire
Hazard Area (Bushfire Prone Area) mapping (July 2014). The data includes Fire Weather Severity (Fire
Danger Index - FDI). A review of the dataset for the assessment area indicates that the site is located
within a band of FDI 46.

2.1.5   Additional Input Parameters
The assumed flame temperature is set at 1,200K and the ambient temperature is set to 35 ̊C in accordance
with Section 7.6 and the fit-for-purpose guidance provided in Bushfire Resilient Communities - Technical
Reference Guide for the State Planning Policy State Interest ‘Natural Hazards, Risk and Resilience –
Bushfire (QFES (2019).




SEPTEMBER 2022                          BUSHFIRE HAZARD ASSESSMENT                                    Page: 12
                                      332 EASTERN BRANCH ROAD, KIN KIN

Used in these records

About this file

File size
5.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Bushfire Assessment_compressed.pdf · 5.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.