Skip to the record
Beware of cheap imitations.

Original source · versioned page text

LATE RFI Attachment 6 - Stormwater Management Plan

of 119

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Very large file: it may take a few minutes

The original of this document is very large (29.9 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
                                                                                             HOW IT WORKS
                                                                                             This technology is a post developed stormwater
                                                                                             treatment system. The SPEL Stormsack provides
                                                                                             effective filtration of solid pollutants and debris typical
                                                                                             of urban runoff, while utilising the existing or new storm
                                                                                             drain infrastructure. The Stormsack is designed to rest
                                                                                             on the flanges of conventional catch basin frames
                                                                                             and is engineered for most hydraulic and cold climate
                                                                                             conditions.

                                                                                             Installation procedures shall include removing the
                                                                                             storm grate, cleaning the ledge of debris and solids,
                                                                                             measuring catch basin clear opening and adjusting
                                                                                             flanges to rest on grate support ledge. Install SPEL

FEATURES
                                                                                             Stormsack with splash guard under curb opening so
                                                                                             the adjustable flanges are resting on the grate support
                                                                                             ledge. Install corner filler pieces. Reinstall storm grate
                                                                                             directly on support flanges rise shall be no more than
                                                                                             3mm.
   Pollutant                                                  Efficiency
                                                                                             Maintenance: Typically the SPEL Stormsack is
   Gross Pollutants (GP)                                            100%
                                                                                             serviceable from the street level, and therefore
   Total Suspended Solids (TSS)                                     61%                      maintenance does not require confined space entry
                                                                                             into the catch basin structure. The unit is designed to
   Total Phosphorus (TP)                                            28%                      be maintained in place with a vacuum hose attached to
                                                                                             a sweeper or a vactor truck. Use only SPEL replaceable
   Total Nitrogen (TN)                                              45%
                                                                                             parts.
*Contact Spel to confirm approved performance for the project LGA




 Application                                                 Regulatory Issue                                 Target Pollutants
 Council Storm Drain Retrofits                               At-source litter capture                         Sediment, Litter, O&G
 Commercial/Retail/Residential                               Stormwater Compliance                            Sediment, Litter, O&G
 Litter Prone Urban Areas                                    Cost effective litter control                    Litter ≥ 5 mm
 Scrap Metal/Solid Waste/Oil Storage/Etc                     Industrial Multi-Sector General Permit           Gross Pollutants, O&G
 Part of Treatment Train                                     Council Stormwater Quality Improvement Targets   Sediment, Litter, O&G
 Construction Sediment/Erosion                               Sediment Control Plan                            Sediment/Erosion Control



 Features                                                                                                                                Standard SPEL
                                                                                                                                         Stormsack to suit
        1. Ultra-Durable Aluminium Frame                                                                                                 Pit Sizes
         • Available in 450x450mm, 600x600mm,
 1.                                                                                                                                      450x450mm
            600x900mm and 900x900mm sizes
         • Custom pit arrangements upon request                                                                                          600x600mm

         Black Poly Surround riveted to Frame                                                                                            900x600mm
 2.
        • Can be cut to suit on site
                                                                                                                                         900x900mm
        Reinforced Stormsack Bag
 3.      • Bag has sewed eyelets                                                                                                         Custom
         • Square bottom design for even distribution                                                                                    sizes (i.e.
        Karabiners attach Bag to Frame for easy                                                                                          1200x900mm)
 4.
        service & replacement                                                                                                            can be
                                                                                                                                         manufactured on
 5.     5. Aluminium Support Angles & Fixings
                                                                                                                                         short lead times




                                                                                                                                             spel.com.au     3
Log in to download the original file

LATE RFI Attachment 6 - Stormwater Management Plan.pdf · 29.9 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.