SQIDEP Evaluation                                                SPEL Basin, Sippy Downs


Performance         Performance Requirement                                           Monitoring action or result         Compliance or
Criteria                                                                                                                  non
                                                                                                                          compliance

                                                                                      retain or detain flows to any
                                                                                      material extent.

                                                                                      Accordingly, the claim does not
                                                                                      include a claim for a volumetric
                                                                                      reduction and so flow monitoring
                                                                                      of the outlet only is acceptable

Precipitation       A pluviometer is required                                         A pluviometer was used to           Compliance
Measurement                                                                           monitor rainfall in 0.2mm
                                                                                      increments.

Rainfall            5 minutes or less.                                                Not reported but based on           Unknown.
recording                                                                             reported rainfall hyetographs it
interval                                                                              appears to report at a high
                                                                                      frequency.

Rainfall            <0.25mm                                                           0.2mm adopted.                      Compliance
recording
increments

Pluviometer         To be calibrated twice during the monitoring period.              Dr Drapper has signed a statutory   Unknown.
calibration                                                                           declaration stating that the
                                                                                      pluviometer was calibrated
                                                                                      annually by Drapper
                                                                                      Environmental Consultants.




                                                                                                                                       16
Log in to download the original file

LATE RFI Attachment 6 - Stormwater Management Plan.pdf · 29.9 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.