                                                                                                      Construction Notes
                                                                                             Timber Frame: Framing to be built in accordance with AS 1684 Termite protected timbers
                                                                                             shall be used on all framing
                                                                                             Approved type flashing & sarking to be attached between cladding & frame along with slab &
                                                                                             frame to prevent moisture getting to the frames                                                  Proposed Pool Deck

                                                                                             All wet areas to be made waterproof or resistant to comply to AS 3740 & BCA 3.8.1
                                                 Exist                                       Linings used shall be approved for use in wet areas & shall be fixed in strict accordance
                                                                                             with Manufactures specifications.




                                                                                                                                                                                                                                                             hown
                                                                                             Water stops or vertical barriers in the waterproofing system be installed to prevent passage                                                                                 1150x3050




                                                                                                                                                                                                                                                          irs not S
                                                                                             of moisture in the floor to non wet areas of building                                                                                                                         Alum/Slid
                                                                                             Recommend Laundry floor to have a dry waste in floor & grade floor to it or to door to




                                                                                                                                                                                                                                                       Ext. Sta
                                                                                             allow for overflow
                                                                                             Wet Areas include Bathrooms Ensuite Laundry & WC or Powder rooms                                                                                                                                     Exist
                                                                                                                                                                                                                                   Exist
                                                                                             Tiled areas: Tiles to laid or fixed to a clean dry substrate to comply to AS 3958                                                                                            2331x600
                      Exist                       Exist
                                                                                                                                                                                                                                                                            Lvrs
                                                                                             Ensure water proofing is dry & is suitable for the adhesives or grouts to be applied to
                                                                  Pool                       Ensure the correct tile is being used for the application (ie. Floor tiles on Floors)

                                                                                             All walls to be checked to ensure they are fixed correctly, straight & plumb prior to fixing
                                                                                             plasterboard or interior lining
                                                                                             Plasterboard or interior linings to be fixed to dry frames in strict compliance with                                                                                                     2331x600
                                                                                             manufactures details. Setting of plasterboard to be done in strict compliance with                                                                                                          Lvr
                       Exist                     W32
                                                                                             manufactures specifications, Sanded to provide a flat smooth finish                                                           Exist               Exist                           Exist

                                                                                             Painting: Paints & application to comply to AS 2311 Min 3 coat application system to be                                                                                                      Exist
                                                                                             used
                                                                                             Substrate to be clean & dry correct type sealers & primers to be used for substrate
                                                                                             If paint is sprayed on then a back roll should be done between coats & after final coat
                                                                                             Mould resistant paint to be used in Bathrooms, Ceilings to have approved ceiling paint
                                                                                                                                                                                                                   Exist
                                                                                             applied & be a matt finish
                                  720 C/V                 Exist                              All external windows & doors to have appropriate flashing & seals fitted to prevent water                                                     Exist                      Exist   Exist
                                                                                             getting into building or to the frame work
                                                                                             For all installations of windows follow manufactures instructions or Installation & Fixing
                                                                                             Guide at www.awa.org.au

                                                                                             New Dwelling; to have Min. 50 % of specified bracing installed prior to roof going on
                                                                                             Existing Dwelling; During construction temporary propping & bracing to consulting Engineers
                                                                                             satisfaction
  Ext. Stairs




                               Exist
                                                                                                                                                                                                                           Northeast Elevation
                                                                     Exist                                                                                                                                   2             1 : 100



                    Southwest Elevation
                1   1 : 100



Not for construction or certification
Client: Mike Shove U2/4 Bryan St Bluetongue Appts Sunshine Beach                     Wind Classification N3                                                                                                                                                           Date        28/02/2018 6:45:18 AM
                                                                                                                                            ACCOLADE Building Designs
RPD: Lot 1 on SP 202482                Parish:                       County: March     Site Area :                                                   Proprietor: Steven Horn                       Mobile: 0407 693 018          Drawn for A3 Sheet
Proposed 3rd Floor Addition & 2nd Floor alterations to Existing Unit                                                                                                                        Email: [email protected] Scale 1 : 100 Sheet No. 5 of 6

Used in these records

About this file

File size
388 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Prelim Plans 28-02.pdf · 388 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.