EXISTING
1000
REVETMENT WALL 1500 JETTY LOADING CRITERIA:
UNDER
JETTY LIVE LOADS: = 2.0 kPa
MOORED VESSEL (MAX.)
EXISTING LENGTH: = 5.0m
WEIGHT: = 1500 Kg.
P1
BLOCK WALL B1
P1
BERTHING VELOCITY: = 0.5m / Second
J1
J1
J1
DO NOT FIX JETTY TO RIGID HANDRAIL TO
1500
BLOCKWALL OR COMPLY WITH NOOSA
REVETMENT WALL. B1 COUNCIL REGULATIONS.
NOTES:
P1
1. UNLESS NOTED OTHERWISE, ALL TIMBER SHALL BE
P1
DURABILITY CLASS 1 OF APPROVED SPECIES AND HAVE
TIMBER STAIRS
STRESS GRADE OF F14.
1613
HANDRAIL
J1
J1
J1
TO BUILDERS
TO DETAIL. 2. UNLESS NOTED OTHERWISE, ALL CONSTRUCTION SHALL
B1 DETAILS. COMPLY WITH THE ENVIRONMENTAL PROTECTION
P1
AGENCY'S OPERATIONAL POLICY - "BUILDING AND
ENGINEERING STANDARDS FOR TIDAL WORKS".
P1 TIMBER STAIRS 3. ALL STAINLESS STEEL BOLTS, SCREWS, RODS, ETC. SHALL
TO BUILDERS
J1
J1
J1
BE APPROVED MARINE GRADE S16. ALL OTHER STEEL
DETAILS. WORK, INCLUDING NUTS, BOLTS, WASHERS, AND SCREWS
J1
3113
SHALL BE HOT DIP GALVANIZED OR STAINLESS STEEL.
241°26'30"
241°26'30"
N
REMOVABLE ALUMINUM 4. TOP OF PILES SHALL BE SEALED AND FULLY CAP FLASHED
LOT: 227
30.564
30.550
SEAT TO DETAIL OR RINGED WITH AN ALUMINIMUM ALLOY OR STAINLESS
RP: N21857 STEEL BAND.
P1
File: C:\- Projects\00 - Black & More\7550 - Noosa Jetty Builders\000 - Archive\7550D - 22 COORAN COURT, NOOSA HEADS QLD\ 7550 -S004(C3) - Site Plan, Framing Plan & Jetty Elevations.dwg
5. DIMENSIONS AND LEVELS SHALL NOT BE SCALED FROM
AREA: 629m² B1 THESE DRAWINGS.
P1
B2 6. ALL LEVELS SHOWN ARE APPROXIMATE ONLY.
1390
ALL LEVELS SHALL BE CONFIRMED ON SITE BY THE
J1
J1
J1
P1 BUILDER PRIOR TO CONSTRUCTION WORKS.
3000
2625
TYP.
1500 FRAMING SCHEDULE
J1 J1
150
1235
J1
J1
J1
1500
J1
J1
BEAMS:
20.117 B2 TREX COMPOSITE B1 - 150 x 75 F14 HWD. BEARER, H6 TREATED.
331°24' P1 DECKING BY OTHERS B2 - 200 x 75 F14 HWD. BEARER, H6 TREATED.
P1
FIXED TO MANUF. SPEC.
JOISTS:
TYP.
150
3800 150 J1 - 150 x 75 F14 HWD. JOISTS AT 450 CRS, H6 TREATED.
TYP. PIERS:
4100 P1 - 200Ø HWD. PIER, H6 TREATED.
10000
ALL EXPOSED TIMBER SHALL BE H6 TREATED.
JETTY PLAN
1:100
1500
NOTE: DO NOT FIX JETTY TOP OF EXISTING
TO BLOCKWALL BLOCK WALL
THE HEIGHT OF PILES ABOVE NATURAL GROUND SHALL NOT RL 2.00 AHD
EXCEED THE PILE DEPTH IN THE NATURAL GROUND. RIGID HANDRAIL TO
COMPLY WITH NOOSA
TIMBER STAIRS COUNCIL REGULATIONS
TO BUILDERS
6710 4100 9308 DETAILS.
10060 10060 RECORD FLOOD LEVEL
RL 2.00 AHD
EXISTING
PROPOSED JETTY DECK RL 1.00 AHD BLOCK WALL
EXISTING JETTY
REFER DETAILS FOR DESIGN
AND PONTOON MAXIMUM WATER
ELEMMENTS
TO BE DEMOLISHED RL 0.44 AHD
P1
TOP OF
P1
P1
REVETMENT
P1
P1
WALL
P1
SEABED
P1
SEABED RL 1.00 AHD
TYP.
3000
EXISTING
REVETMENT
TYP.
TYP.
3000
3000
WALL
STONE PITCHING
SITE PLAN
1:200
JETTY FRONT ELEVATION JETTY SIDE ELEVATION
1:100 1:100
Printed: 15 August 2019, 8:25 AM
CONSTRUCTION ISSUE
NOOSA JETTY BUILDERS © Black & More Client Project Drawing Title
JoB No: 1190 This document is and shall remain
Black & More
ABN 19 609 960 232
NOOSA JETTY BUILDERS PROPOSED NEW JETTY
Address: the property of Black & More. Address
22 COORAN COURT, NOOSA HEADS QLD SITE PLAN, FRAMING PLAN
Revisions
This document may only be used 7 / 28 Sunshine Beach Road,
22 COORAN COURT, NOOSA HEADS
C3 CONSTRUCTION ISSUE FM FM 15/08/19 LOT 227 ON N21857
for the purposes for which it was
commissioned and in accordance
Noosa Heads QLD. 4567
PO Box 611, Noosa Heads QLD. 4567 Drawn Drawing Approved Date 15/08/19
AND JETTY ELEVATIONS
C2 CONSTRUCTION ISSUE FM FM 31/07/19 Client: with the Terms of Engagement for
Telephone (07) 5447 4444
ST Check FM
GRAHAM SCUDAMORE-SMITH the commission. Unauthorised use Drawing Size Scale (A3 size) Drg No Revision
C1 CONSTRUCTION ISSUE FM FM 09/07/19 RPEQ 19951
No. Description Reviewed Approved Date
of this document in any form
whatsoever is prohibited.
Email
Internet
[email protected]
www.blackm.com
Designed
FM
Design
Check DS Drawing is not to be used for construction unless approved A3 NOT TO SCALE 7550D- S004 C3
External References: B&M-JETTY-TITLE-A3_e.dwg
See the original