Information Request OPW25 0057 (As Published) · OPW25/0057

of 4

Text shows just the words. Original shows the document exactly as it was published.

                                                                  Officer:            Felix Gough
                                                                  Direct Telephone:   07 5329 6561
                                                                  Our Reference:      OPW25/0057
                                                                  Your Reference:     100988

                 13 May 2025


                 Noosa Shire Council
                 C/- Murray & Associates (Qld) Pty Ltd
                 PO Box 141
                 NAMBOUR QLD 4560
                 [email protected] & [email protected]



                 Dear Sir
                                                   Information Request
                                                       Planning Act 2016

                 I refer to your application and advise that Council requires further information to satisfactorily
                 assess the proposal.
                 1.     APPLICATION DETAILS

                  Application No.                OPW25/0057

                  Proposal:                      Roadwork, Landscaping, Stormwater, Earthworks

                  Street Address:                62 Lake Macdonald Dr Cooroy Qld 4563

                  Real Property Description:     Lot 105 SP 118458

                  Planning Scheme:               Noosa Plan 2020 (25 September 2020)

                 2.     INFORMATION REQUIRED

                 The information requested is set out below:


                 Item – Associated Application
                 Associated development application RAL25/0004 has not yet been decided.
                 Information Required
                 1.     Provide an updated response following the decision of RAL25/0004, demonstrating
                        compliance with relevant conditions.


                 Item - Stormwater Drainage Design
                 Information Required
                 2.     Provide inlet control culvert check calculations for the culvert crossing of the drainage
                        swale in Lot 100 (1/M to 2/M)


                 ABN 97.969.214.121                                                                     PO Box 141
                 noosa.qld.gov.au                                                                Tewantin QLD 4565
                 [email protected]                                                                07 5329 6500
                                                                                                          Page 1 of 4
Document Set ID: 23708018
Version: 5, Version Date: 13/05/2025
Full text of the other 3 pages

Page 2

                 Issue - Stormwater Quantity
                 Information Required
                 3.     Provide an update to the Flood Hazard Assessment report which specifically examines
                        the impact resulting from changes in the site landuse/imperviousness on stormwater
                        characteristics within the downstream road network and downstream private land.
                        Where unacceptable impacts are predicted to occur, these impacts are to be mitigated
                        through the use of a detention basin or other means.


                 Item - Climate Change
                 Information Required
                 4.     Clarify what climate change assumptions have been adopted in the drainage design in
                        order to meet PO2 of the Water Quality and Drainage Code. It is suggested that SPP2-
                        4.5 and a planning horizon of 2100 be adopted consistent with the current methodology
                        of ARR. This should be applied to both the drainage design and flood hazard
                        assessment.


                 Item – Stormwater Structures 2/A & 4/A
                 Stormwater structures (2/A & 4/A) do not align with the 600mm channel (900mm x 900mm
                 structures).
                 Information Required
                 5.     Provide a typical detail as they do not reflect standard drawing DS-050.


                 Item – Stormwater Structure 6/A
                 Structure 6/A appears to include two lateral inlets, typically this arrangement is avoided as per
                 QUDM 7.6.3. It’s noted outlet velocities to the bioretention sediment forebay (Structure 7/A)
                 should be minimised. The design pipe flows from 6/A to 7/A appear to exceed the design pipe
                 capacity at grade shown on drawing C320 Rev D.
                 Information Required
                 6.     Review the design and provide further engineering justification and/or amendments if
                        required.


                 Item – Erosion and Sediment Control (ESC)
                 The ESC plans include high efficiency sediment (HES) basins for catchment 1 & 2. HES Basin
                 1 shows overflow discharging to an existing filed inlet to the northeast. It’s unclear where the
                 forebay is located and how runoff will be directed through the basin.
                 Information Required
                 7.     Prove additional information addressing the abovementioned.


                 Item – External Roadworks
                 Further details are required for the Lake Macdonald Drive roadworks.
                 Information Required
                 Provide amended plans addressing the following;




                                                                                                          Page 2 of 4
Document Set ID: 23708018
Version: 5, Version Date: 13/05/2025

Page 3

                 8.     The pathway along Lake MacDonald Drive follows the TMR SEQ Principal Cycle
                        Network and requires coloured treatments (e.g. CCS Black 44 colour treatment for
                        footpath infrastructure along the Network).
                 9.     Possibility for Cycle Green Treatment (line marking) along the 2m cycle lane at the
                        Dianella Court/Lake McDonald Drive Intersection.
                 10.    Kerb ramp & crossing TGSI’s are to be pavers (detail to be provided).


                 Item - Fauna Management
                 The application includes the removal of vegetation within Councils Road reserve and within
                 the property to facilitate road and bioretention basin infrastructure.
                 Information Required
                 11.    Provide to council for endorsement a fauna management plan, (or part thereof) prepared
                        by a qualified person to address fauna management during the vegetation clearing
                        phase of the site.


                 Item - Miscellaneous
                 Information Required
                 12.    All timber bollards/garden edging/etc is to be ACQ treated (Not CCA treated).


                 Item – Portable Long Service Leave Levy
                 The provided DA Form 1 has nominated evidence of portable long service leave levy will be
                 provided before the application is decided.
                 Information Required
                 13.    Provide evidence the portable long service leave levy has been paid.




                 3.     DUE DATE FOR RESPONSE TO INFORMATION REQUEST

                 The due date for providing the requested information is 13/08/2025 Email your response to
                 [email protected]. Please advise Council of your response to this information request
                 in accordance with section 13 of the Development Assessment Rules.
                 If you do not provide a response before the due date, it will be taken as if you have decided
                 not to respond to the information request and Council will continue with the assessment of
                 your application.
                 4.     OTHER DETAILS

                 You can follow the progress of this application online at www.noosa.qld.gov.au. The “Online
                 Services” page can be accessed via "Quick Links" on the left hand side of the screen.
                 Should you have any further queries in relation to the above, please do not hesitate to contact
                 me on the number above.




                                                                                                        Page 3 of 4
Document Set ID: 23708018
Version: 5, Version Date: 13/05/2025

Page 4

                 Yours faithfully,




                 Felix Gough
                 Development Engineer




                                        Page 4 of 4
Document Set ID: 23708018
Version: 5, Version Date: 13/05/2025

Used in these records

About this file

File size
95 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Information Request OPW25 0057 (As Published).pdf · 95 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.