Original source · versioned page text
240808 - Sprout As Consturcted 9 BARTLETT RD NOOSAVILLE INDUSTRIAL WAREHOUSES - REV D (002)
Original PDF page 14, section 1. The text section number identifies this passage in the reader.
4 3 2 1
Structure as per Structural Engineers details
100 90 CBR
30 90
Raking Versilx soffit
Raking Versilx soffit ERS
James Hardie 'Linea'
Wall cladding WT4 steel roof beam as per Structural Engineers details
ERS
WT4b
CWC fixed to battens PCP
to 90mm wall frame
PJ mechanical exhaust PJ PJ
Balcony Tenancy 3 duct
Modwood decking 137 x 32mm Store Room James Hardie
Fixed with KlevaKlip
'Villaboard' cladding
Snap-Loc clip system. Colour 'Charcoal'.
Metal cladding
HWD joists with paint finish. Tenancy 3
6mm Villaboard sheeting fixed to battens
RL +22.470
cladding to run through. Non -loadbearing ceiling joists
Mezzanine
PCP
Modwood soffit batten
68 x 17mm Fixed with KlevaKlip
Snap-Loc clip system. Colour 'Charcoal'. James Hardie Villaboard PCP PCP 1800h timber fence.
Cladding
Toilet
3,320
3,320
3,320
Refer drawing CD90.01 for details Replace existing boundary
PCP wall due to structural
inadequacy with 1800 high
Exisitng wall Detail 03 timber fence on top of
Render and paint finish'. CD80.01 concrete sleeper retaining
30 50mm set down to slab wall.
slab setback 30mm from Grid line 3
RL +19.150
Ground Floor
SECTION C Retaining wall &
footings to civil
Scale 1:50 engineers detail
D C B A
C1 B1 A1
4,770 5,160 4,965 4,535 5,360 5,170
Outside line of wall
Tilt panel walls must continue to Outside line of wall/floor
underside of roof sheet, to ensure Tilt panel walls must continue to underside of roof
fire separation compliance. Tilt panel walls must continue to Tilt panel walls must continue to sheet, to ensure fire separation compliance.
Foil faced insulation blanket on Centre of wall/columns
Profiled vermin stop to underside underside of roof sheet, to ensure CBR galvanized safety mesh over top underside of roof sheet, to ensure Profiled vermin stop to underside of roof sheeting to
of roof sheeting to close gap fire separation compliance. of new roof frame structure fire separation compliance. CBR close gap over tilt panel
over tilt panel
Colorbond capping
R2.5 Bradford Gold ceiling insulation
ERS ERS ERS top of walls to be braced
PB to engineer's detail
SHS column SHS column
Metal Cladding
Suspended plasterboard ceiling
1,200
AW.10
Tenancy 3 Tenancy 2 Tenancy 1
WT 3a WT 3a
2,700
TD.09 R1.3 insulation
PCP PCP PCP
Tenancy 3 Tenancy 2 Tenancy 1 WT 3a
1,200
Mezzanine
1,000
Store Room Store Room Metal Cladding
Steel bearer HWD timber stair . Plasterboard lining to U/S
Packing as required for wall cladding
Selected wall insulation
to Western wall
Stair Stair Raking wall to
WT 3
close off stair
WT 5
void
3,320
3,320
WT 5
AD.08 AD.07 MD.02
WT 5
SECTION D
Scale 1:50
REV DESCRIPTION DRAWN DATE
project drawing
A BUILDING APPROVAL AC/NN 03/08/22
B BUILDING APPROVAL AC/NN 12/08/22 Suite 2, Suncoast Resort Business Centre PROPOSED NEW INDUSTRIAL SECTIONS C and D
C
D
BUILDING APPROVAL
B.A - AS BUILTS FOR CERTIFICATION
KT/AC
NN
13/09/22
08/08/24
Cnr Gardak Street
SUNCOAST & Surf Road
RESORT BUSINESS CENTRE WAREHOUSES
Alexandra
SUITE 2 Headland Q 4572
CNR GARDAK ST & SURF RD Copyright of this document remains the exclusive
for property of SPROUT ARCHITECTS PTY LTD
POALEXANDRA HEADLAND
Box 6232, Maroochydore BC Q 4558 Qld 4572 ABN 23 123 917 724.
PO BOX 6232 MAROOCHYDORE BC Qld 4558 OLD SEA DOG 9 PTY LTD date 8/08/2024 drawn KT/AC scale AS SHOWN Contractors are to verify all dimensions and levels on
P PH
07 :5443 5028
07 5443 F 07 5479 2380 | ABN
5028 FAX:07235479
123 917
2380724 at
@ A1
site prior to commencing. Report all discrepancies to
[email protected]
ABN | sproutarchitects.com.au
23 123 917 724 9 BARTLETT ROAD NOOSAVILLE QLD
the Architect. Use figured dimensions in preference
to scaled.
EMAIL: [email protected] drawing no. 21015 CD30.04 revision D
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.