Original source · versioned page text
240808 - Sprout As Consturcted 9 BARTLETT RD NOOSAVILLE INDUSTRIAL WAREHOUSES - REV D (002)
Original PDF page 2, section 1. The text section number identifies this passage in the reader.
SITE INFORMATION 9 BARTLETT ROAD NOOSAVILLE QLD LOT 48, 9 BARTLETT ROAD, NOOSAVILLE PLAN NO. RP173566 PROPOSED NEW INDUSTRIAL WAREHOUSES PARISH. NOOSA COUNTY. MARCH B .A ISSUE LOCALITY. NOOSAVILLE LOCAL GOVERNMENT. NOOSA SHIRE COUNCIL DRAWING LEGENDS: Elevation / Section Legend Setout Legend Floor / Roof Plan Legend Reflected Ceiling Plan Legend Door & Window Legend Detail Wall Type Legend WT 1 COL Reinforced concrete column. Refer to A/C Air-Conditioning unit as per General WALL TYPE 1, PRECAST TILT-UP PANEL. BAL Balustrade typical - 90mm wall with AFFL Above finished floor / slab level Performance criteria - FRL 90/90/90 (when closer than 1.5 m to a structural engineer's drawings for Notes Glazed Door / Window number Linea Cladding to outside and 6mm CBS 0.42 mm BMT Lysaght Colorbond fire-source feature), Thermal, no requirement. Villaboard cladding to inside details. BAL Balustrade typical - Custom orb roof sheeting, direct fixed to XX.XX Glazing unit Nominated System - 150 mm precast and reinforced concrete tilt- BC Colorbond flashing to roof ends DO Grated inlet as per civil engineer's Min. 1000h high wall lined with roof structure and installed in accordance up panels to structural engineer's details. Select applied proprietary CBR 0.42 mm BMT Lysaght Colorbond drawings and details cladding as indicated on drawings Door / Window Type Trimdek roof sheeting, laid over Anticon 60 DP UPVC rainwater downpipe to LOSP treated pine top rail with manufacturer's specifications and details.Colour Colorbond "Surfmist" finish. type paint finish as scheduled and where nominated (refer Sheet no. Sheet Name: Status hydraulic consultants details, with a 45° BC Colorbond flashing to roof ends Door number elevations). R1.3 Foil faced roofing insulation blanket on CF Ceiling finish Maximum total wall system thickness exclusive of linings = 150 mm galvanized safety mesh, Installed in transition, fixed to wall BL Vehichle Bollard with light CD00.01 COVER SHEET D CH Ceiling Height XX.XX Door unit WT1 a accordance with manufacturer's specifications on stand-off brackets, select paint BL1 Vehichle Bollard COL Reinforced concrete column, WALL TYPE 1a, PRECAST TILT-UP PANEL. finish to match wall finish BR Bicycle Rack Door Type and details. FFL Finished floor / slab level CBR 0.42 mm BMT Lysaght Colorbond 300 mm Ø. Refer to structural Performance criteria - FRL 90/90/90 (when closer than 1.5 m to a CD10.01 LEGENDS & DRAWING SCHEDULE D COL Reinforced concrete column. Refer to engineer's drawings for details. fire-source feature), Thermal - Insulation to inside face R1.3 PF Pad footing as per Trimdek roof sheeting, laid structural engineer's drawings for details. structural engineer's details over roofing blanket insulation, D.P UPVC rainwater downpipe to hydraulic AD.XX 10mm Plasterboard finish fixed to furring channels . Paint finish CD10.02 GENERAL NOTES & SAFETY REPORT D DP UPVC rainwater downpipe to hydraulic consultants details, with a 45° transition, Combined Glazing Unit Select applied proprietary type paint finish as scheduled and where consultants details, with a 45° transition, fixed RL Reduced level Installed in accordance with AW.XX RTR Roller door threshold as per manufacturer's specifications and fixed to wall on stand-off brackets, select nominated (refer elevations). CD10.03 SAFETY IN DESIGN REPORT 1 D to wall on stand-off brackets, select paint paint finish to match roof sheeting. finish to match wall finish. structural engineer's details details. ERS Exposed roof structure. Foil faced Combined Glazing Units WT 2 (Car park only) CD10.04 SAFETY IN DESIGN REPORT 2 D FC Versilux 9mm FC soffit butt jointed SC Slab saw cut as per structural COL Reinforced concrete column. Refer insulation blanket on galvanized safety WALL TYPE 2, EXTERNAL BLOCKWORK WALLS. FF Floor finish as selected engineer's details to structural engineer's drawings for Aluminium-framed windows (AW) units that incorporate mesh over top of new roof frame structure Performance criteria - FRL no requirement, Thermal, no CD10.05 SAFETY IN DESIGN REPORT 3 D FG Fascia gutter, as per hydraulic engineer's SHS Hot dipped galvanized square details. FG Fascia gutter, colour to match roof Glazing Doors (AD) are tabled in the Door and Window requirement. details hollow section as per structural CWC Metal cladding. Refer elevations sheeting, as per hydraulic Nominated System - 190 mm core-filled and reinforced concrete FL Colorbond flashing engineer's detail DB Distribution Board engineer's details Schedule with the corresponding Door. For example CD10.06 SITE PLAN D TR Door threshold as per AS 1428.1 DO Grated inlet as per civil engineer's refer to AD.01 for WD.01 where these exist as a blockwork wall. Select applied proprietary type waterproof render PB 10 mm plasterboard wall / ceiling FS Floor structure / concrete slab and membrane paint finish to both sides as scheduled. Provide lining, flush finished and square set. drawings and details SHS Hot dipped galvanized square combined glazing unit. drainage and backfill to top end side of wall as per structural / civil CD20.01 GROUND FLOOR PLAN D Select paint finish. Notes: DP UPVC rainwater downpipe to hollow section as per structural engineer's details. PJ Panel Joint Refer to civil and structural engineer's hydraulic consultants details, with a engineer's detail AD Aluminium-framed door Maximum total wall system thickness exclusive of linings = 190 mm CD20.02 MEZZANINE D PCP 150 mm precast and reinforced concrete drawings for more information and other 45° transition, fixed to wall PCO Select paint finish to concrete soffit AW Aluminium-framed window tilt-up panels to structural engineer's details. building & civil requirements. on stand-off brackets, select paint CD20.03 ROOF PLAN D U/S Underside FGL Fixed glass panel WT 3 Select applied proprietary type paint finish finish to match wall finish. VS 9 mm Versilux FC soffit sheet on FSL Finished slab level WALL TYPE 3, INTERNAL 90mm STUD WALLS. DRY Dryer as scheduled Refer to CD10.02 for General Notes DW Dishwasher furring channels,all fixings to be counter TD Timber-framed door Performance criteria - FRL, no reqirement, THERMAL -no thermal CD30.01 NORTH & SOUTH ELEVATIONS D PCO 150 mm precast and reinforcedconcrete tilt- and other building requirements. sunk and flush finished. Installed MD Industrial Roller Shutter Door requirement FF Floor finish - as scheduled up panels to structural engineer's details. FFL Finished floor / slab level in accordance with manufacturer's VSD Vision safety decal as per 10 mm plasterboard to internal faces, selected paint finish. CD30.02 EAST & WEST ELEVATIONS D Off-form finish specification. Select paint finish. PF Pad footing as per Joinery Legend FG Fascia gutter, colour to match roof WPB Water resistant plasterboard clause 5.1 AS1288 WT3a CD30.03 SECTIONS A and B D structural engineer's details sheeting, as per hydraulic RBW 190 mm core-filled and reinforced concrete ADJ Adjustable Shelf engineer's details flush finished and square set. Select Door & Window Schedule Notes WALL TYPE 3, INTERNAL 90mm STUD WALLS. paint finish as scheduled Performance criteria - FRL, no reqirement, THERMAL - as per CD30.04 SECTIONS C and D D blockwork to structural engineer's details. BM Basin mixer - as scheduled FL Colorbond flashing - All dimensions shown are approximate openings only. Energy Efficiency report Select proprietary-type waterproof applied BT Benchtop, Select stone finish - as scheduled HC Hose cock non-combustible render & membrane paint CH Coat / clothes hanger - as scheduled HWD Hardwood Exit light. Refer to electrical engineer's All measurements to be taken from job on site. 10 mm plasterboard to internal faces, selected paint finish. CD30.05 SECTIONS E and F D HWS Hot Water System to electrical EX - All glazing shall be in powdercoated aluminium system to all masonry block surfaces such CT Cooktop - as scheduled drawings for details as carpark retaining walls. DRW Draw engineer's specifications frames with clear glass unless noted otherwise. CD30.06 EXTERNAL COLOUR SELECTIONS D MB Motorcycle parking space WT 4 RL Reduced level DR Dryer - as scheduled Painted concrete soffit - All mezzanine windows shall have painted 19 mm WALL TYPE 4, EXTERNAL 90mm STUD WALLS. SH Sunhood - 9mm flate plate select DW Dishwasher - as scheduled MSB Meter boxes / main switchboard pine reveals & 42x12 mm pine architraves. Builder to Performance criteria - FRL, no reqirement, THERMAL , as per CD40.01 GROUND FLOOR SETOUT D aluminium window awning over. 'Heka' EQ Equal dimension NBN National broadband network Plasterboard ceiling lining allow for reveals in opening sizes. Energy efficiency report. proprietart type sun hood o.e.o FF Floor finish connection flush finished / square set 10 mm plasterboard to internal faces, select paint finish. CD50.01 REFLECTED CEILING PLAN D FW Floor waste PJ Panel Joint - Architraves to be 42x12 mm pine with bevelled edge, WBC 1 James Hardie "Linea", 150 mm fibre cement External cladding -James Hardie 'Linea' 150mm FC weatherboard weatherboard system installed over vapour GPO General power outlet RB Waste Bins semi-gloss paint finish. CD70.01 DOOR & WINDOW SCHEDULES D Stramit Premier 300 soffit cladding permeable membrane. GR Grab rail - as scheduled REF Refrigerator - All glazing shall be in accordance with AS 2048 & AS RL Reduced level WT4a WBC 2 James Hardie FC wall cladding - "Matrix" HWS Hot Water System to electrical engineer's 1288 and shall suit site terrain category. CD80.01 DETAILS D RTR Roller door threshold as per Versilux FC soffit WALL TYPE 4a, EXTERNAL STUD WALLS. Compressed FC cladding details and specifications structural engineer's details flush finished. - All internal hinged doors to be in timber frames. Performance criteria - FRL, no reqirement, Thermal - no CWC Lysaght Enseam 265 installed over battens KB Kickboard, laminate finish - as scheduled CD90.01 JOINERY DETAILS D S Sink - as scheduled requirement over Vapour permeable sisalation. LM Laminate - as selected MI Mirror SH Sunhood - 9mm flate plate select Reflected Ceiling Notes External cladding -James Hardie 'Linea' 150mm FC weatherboard MX Sink mixer - as scheduled aluminium window awning over. Notes: to outside and James Hardie Matrix 9mm fixed over Matrix Cavity CD90.02 SCHEDULE OF INTERIOR AND EXTERIOR FINISHES D - All ceiling levels measured from finished floor level trim to inside of wall/balustrade OV Oven - as scheduled 'Heka' proprietart type sun hood Refer to CD10.02 for General Notes REF Refrigerator - as scheduled o.e.o respective to each room. and other building requirements. CD90.03 SCHEDULE OF FIXTURES AND JOINERY D SHR Shower - All lights & electrical fittings by others WT4b RH Rangehood - as scheduled SHS Hot dipped galvanized square - Refer specification for additional information and WALL TYPE 4b, EXTERNAL STUD WALLS. RL Reduced level Refer to Schedule of interior finishes for more hollow section as per structural CWC fixed to top hat sections and James Hardie Matrix 9mm S Sink - as scheduled fitting selections. information and other building requirements. engineer's detail fixed over Matrix Cavity trim to inside of wall/balustrade SD Soap dispenser - as scheduled - All electrical works to be carried out by licenced SEAT Shower Bench Seat - as scheduled SW Indicative Storm Water Service TR Door threshold as per AS 1428.1 electrical contractor. WT 5 SH Shelf WB Wall basin - as scheduled - All electrical and lighting fittings & fixtures and their WALL TYPE 5, INTERNAL 90mm STUD WALLS. SHC Shower curtain WC Water closet - as scheduled installation to comply with the NCC and relevant Performance criteria - FRL no requirement, Thermal, no SHR Shower WBC1 FC cladding Type 1. Refer requirement. SM Shower mixer - as scheduled Australian Standards. elevations Provide 18 mm Marine grade plywood to inside of PWD , floor to SR Shower rose - as scheduled WBC 2 FC cladding Type 2. Refer ceiling, 6 mm Villaboard lining to all sides, waterproofing where SS Shower shelf - - as scheduled elevations required , select paint / tilefinish. TD Towel dispenser - as scheduled TRH Toilet roll holder- as scheduled WM Washing Machine Notes: TS Tiled skirting - as scheduled WS Wheel stop as per AS 2890.1 Refer to CD10.02 for General Notes WB Wall-hung basin - as scheduled requirements and other building requirements. WC Water closet - as scheduled WT X Wall type - refer to wall type WPB Water resistant plasterboard, schedule Refer to Schedule of interior finishes for more select paint finish - as scheduled information and other building requirements. WM Washing Machine - as scheduled Glazed Door / Window number WT Wall tiles - as scheduled WT X Wall type - refer to wall type schedule XX.XX Glazing unit Notes: Door / Window Type Refer to CD10.02 for General Notes Door number and other building requirements. XX.XX Door unit Refer to Schedule of Appliances, Schedule of Door Type Fittings & Fixtures, Schedule of Interior Finishes and AD.XX Schedule of Joinery for more information and other Combined Glazing Unit building requirements. AW.XX Joinery Notes Combined Glazing Units Aluminium-framed windows (AW) units that incorporate - Building and joinery contractor to confirm all joinery finishes, Glazing Doors (AD) are tabled in the Door and Window sizes for appliances, fixtures, fittings, accessories and the Schedule with the corresponding Door. For example like prior to construction and installation of all joinery and refer to AD.01 for WD.01 where these exist as a plumbing related items. combined glazing unit. - Provide noggins, packing and/or blocking as required in wall frames for direct fixing of all joinery, fixtures, accessories REV Set down DESCRIPTION DRAWN DATE and the like. Setdown joists in bath room and under W.M. - Tiles shown are indicative only. Confirm tile size and setout 50mm to allow fall to floor waste in tile project drawing A BUILDING APPROVAL AC/NN 03/08/22 with proprietor. B bedding. JH BUILDING Secura flooring to be full APPROVAL AC/NN 12/08/22 Suite 2, Suncoast Resort Business Centre PROPOSED NEW INDUSTRIAL LEGENDS & DRAWING SCHEDULE - Provide shelf stiffening rails and wall plates where required. waterproofed to puddle flange drain C D - Confirm selection of all finishes and fixtures with proprietor. BUILDING APPROVAL B.A - AS BUILTS FOR CERTIFICATION KT/AC NN 13/09/22 08/08/24 Cnr Gardak Street SUNCOAST & Surf Road RESORT BUSINESS CENTRE WAREHOUSES Alexandra SUITE 2 Headland Q 4572 CNR GARDAK ST & SURF RD Copyright of this document remains the exclusive for property of SPROUT ARCHITECTS PTY LTD Notes: POALEXANDRA HEADLAND Box 6232, Maroochydore BC Q 4558 Qld 4572 ABN 23 123 917 724. Refer to CD10.02 for General Notes PO BOX 6232 MAROOCHYDORE BC Qld 4558 OLD SEA DOG 9 PTY LTD date 8/08/2024 drawn KT/AC scale AS SHOWN Contractors are to verify all dimensions and levels on and other building requirements. P PH 07 :5443 5028 07 5443 F 07 5479 2380 | ABN 5028 FAX:07235479 123 917 2380724 at @ A1 site prior to commencing. Report all discrepancies to [email protected] ABN | sproutarchitects.com.au 23 123 917 724 9 BARTLETT ROAD NOOSAVILLE QLD the Architect. Use figured dimensions in preference Refer to Schedule of exterior and interior to scaled. EMAIL: [email protected] drawing no. 21015 finishes, as well as Schedule of Fittings & CD10.01 revision D Fixtures for more information and other building requirements.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.