Original source · versioned page text
240808 - Sprout As Consturcted 9 BARTLETT RD NOOSAVILLE INDUSTRIAL WAREHOUSES - REV D (002)
Original PDF page 22, section 1. The text section number identifies this passage in the reader.
SCHEDULE OF EXTERIOR & INTERIOR FINISHES
NOTES: - INSTALLATION AND MAINTENANCE IS TO COMPLY WITH MANUFACTURER'S
INSTRUCTIONS AND AUSTRALIAN STANDARDS, FOR ALL SPECIFIED PRODUCTS.
- SCHEDULES TO BE READ IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS.
- SHOULD AN ALTERNATIVE TO THE SPECIFIED ITEM BE AVAILABLE, THE ITEM MUST BE
APPROVED BY ARCHITECT PRIOR TO ORDERING.
- ALL COLOUR SELECTIONS SHALL BE REVIEWED AND FINALISED WITH ARCHITECT AND
PROPRIETOR PRIOR TO ORDERING; ALLOW SUFFICIENT TIME FOR COLOUR REVIEW AND
APPROVAL OF FINAL COLOUR SELECTIONS.
LEGEND: TBS - TO BE SELECTED
OEA - OR EQUAL APPROVED
UNO - UNLESS NOTED OTHERWISE
CODE SELECTION AND FINISH APPLICATION COMMENTS CODE SELECTION AND FINISH APPLICATION COMMENTS
N/A 150 / 180 mm reinforced concrete slab on 200 mm cement treated sub Main Driveway and car spaces Coordinate with civil and
Typical Driveway base on compacted subgrade as per structural engineer's structural services.
requirements, off-form finish.
N/A 150 mm reinforced concrete slab on 200 mm cement treated sub base Tenancy walkway and dedicated tenancy Coordinate with civil and
Tenancy pavement on compacted subgrade as per structural engineer's requirements, car spaces structural services.
decorative finish.
COLOUR: CCS Oynx or equal approved
N/A 150 mm reinforced concrete slab on granular fill material as per Tenancy slab (ground & mezzanine) Coordinate with civil and
Main Tenancy slab structural engineer's requirements, steel trowel finish. structural services.
N/A Ceramic Floor Tile, 600 x 600 TBS, Slip Rating to be R10 laid to fall to PWD Toilets
PWD Floor floor wast. Tile insert required to floor waste.
CBR 0.42 mm BMT Lysaght Trimdek Colorbondroof sheeting with Tenancy roof sheeting
concealed fixings. Install to manufacturer's specifications.
COLOUR: Shale Grey
10mm plasterboard wall and ceiling linings 13mm preferred TBC with
PB Tenancy 1 office wall and ceiling finish
Square set cornice owner
PCO 150 mm reinforced concrete tilit-up panels as per structural engineer's Tenancy tilt-up panels - refer elevations / sections
requirements, off-form finish.
PCP 150 mm reinforced concrete tilit-up panels as per structural engineer's Tenancy tilt-up panels - refer elevations / sections
requirements, paint finish.
RBW 190 mm core-filled reinforced concrete block walls to structural Retaining wall to car park
engineer's detail. Select applied proprietary skim cote render and
painting is required to all masonry block surfaces such as carpark
retaining walls.
TB1 Modwood 68x17 battens fixed to u/s of timber joists to manufacturers
requirements Balcony soffits
VS James Hardies 9mm Versilux soffit sheeting. Exressed Butt joints. All soffits - refer ceiling plan
Countersunk screw fixings
WBC 1 James Hardie 'Linea' 150 mm fibre cement weatherboard cladding External wall cladding to tenancy mezzanines
and fixing system. All panels to be factory sealed, cut panels to be
sealed on site using approved sealant. Counter-sink and epoxy
conceal all fixings, install on proprietary-type top hats and gasket
system, refer to manufacturer's specifications for details. Paint finish.
WBC 2 James Hardie Villaboard 6mm cladding . Flush set joints . Paint Cladding to tenancy mezzanines Internal
finish. balustrade internal faces and PWD toilet walls
WBC 3 James Hardie 'Matrix' fibre cement weatherboard cladding and fixing Cladding to tenancy mezzanines external
system . All panels to be factory sealed, cut panels to be sealed on balustrade internal face
site using approved sealant. Counter-sink and epoxy conceal all
fixings, install on proprietary cavity trim , refer to manufacturer's
specifications for details. Paint finish.
WPB 1x 13 mm moisture resistant plasterboard flush finished and square PWD Toilets wall linings Fixings to be concealed.
set, installed on proprietary 28mm furring channels OR direct fixed
to 90 mm stud frame (refer floor plans for wall types). Paint finish.
FINISH: One coat applied sealer, one coat of undercoat.
COLOUR: Dulux Whisper White SW1C2
WT 300x 600 Rectified edge ceramic wall tile to be selected and splashback PWD Toilets walls . Refer to elevations
feature tile (size and type to be selected) Seal any natural stone tiles
Kitchen splashbacks - refer to elevations
TS 300x 600 Rectified edge ceramic wall tile to be selected (size and Skirting tiles in PWD Toilets and bathroom. Refer to Seal any natural stone tiles
type to be selected) joinery detail elevations
REV DESCRIPTION DRAWN DATE
project drawing
A BUILDING APPROVAL AC/NN 03/08/22
B BUILDING APPROVAL AC/NN 12/08/22 Suite 2, Suncoast Resort Business Centre PROPOSED NEW INDUSTRIAL SCHEDULE OF INTERIOR AND EXTERIOR
C
D
BUILDING APPROVAL
B.A - AS BUILTS FOR CERTIFICATION
KT/AC
NN
13/09/22
08/08/24
Cnr Gardak Street
SUNCOAST & Surf Road
RESORT BUSINESS CENTRE WAREHOUSES FINISHES
Alexandra
SUITE 2 Headland Q 4572
CNR GARDAK ST & SURF RD Copyright of this document remains the exclusive
for property of SPROUT ARCHITECTS PTY LTD
POALEXANDRA HEADLAND
Box 6232, Maroochydore BC Q 4558 Qld 4572 ABN 23 123 917 724.
PO BOX 6232 MAROOCHYDORE BC Qld 4558 OLD SEA DOG 9 PTY LTD date 8/08/2024 drawn KT/AC scale AS SHOWN Contractors are to verify all dimensions and levels on
P PH
07 :5443 5028
07 5443 F 07 5479 2380 | ABN
5028 FAX:07235479
123 917
2380724 at
@ A1
site prior to commencing. Report all discrepancies to
[email protected]
ABN | sproutarchitects.com.au
23 123 917 724 9 BARTLETT ROAD NOOSAVILLE QLD
the Architect. Use figured dimensions in preference
to scaled.
EMAIL: [email protected] drawing no. 21015 CD90.02 revision D
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.