Original source · versioned page text
240808 - Sprout As Consturcted 9 BARTLETT RD NOOSAVILLE INDUSTRIAL WAREHOUSES - REV D (002)
Original PDF page 8, section 2. The text section number identifies this passage in the reader.
Driveway Crossover crossover in elevations
18.2
AD.07 MB MB accordance with WBC 2 FC cladding Type 2. Refer
mech ventilation WS Cantilvered beam over
Existing stormwater FF: Conc. D.A condition 23 elevations
to mechanical engineers specification Beam over Motorised WM Washing Machine
drainage to be removed AW.06
(RS-051)
TR Powdercoated WS Wheel stop as per AS 2890.1
4 x lockers
RB AD.05
aluminium sliding entry Entry requirements
12 Refer site plan 10.06 for
18.8
WT X Wall type - refer to wall type
RB
TD.04
Entry parking setout gate schedule
Balcony over
WT 5 620
90
S
FF: Tiles Timber stair to storage room. RL18.920
Landscape fall Glazed Door / Window number
Recreation & PWD SHR
2,200
HWS WS XX.XX Glazing unit
Staff area. A/C BR
WB WC UP 3 x Bicycle spaces 5 Door / Window Type
41.0 m2 11
150
REF.
19.19
Top of Wall
D.P.
C C Door number
RL18.910
PJ PJ PJ
150
150
WT 1
1800mm High
WS MB MB XX.XX Door unit
1,706
timber fence Door Type
AD.XX
RL18.901
150 13,805 90 2,800 90 6,915 150 6 Combined Glazing Unit
50
AW.XX
MD.04
WS BL
30.01
5,130
N
Tenancy 3
Roller Combined Glazing Units
WT 1
RTR
Door
Replace existing Aluminium-framed windows (AW) units that incorporate
boundary wall due to RL 19.150 line of storage 19.115 Glazing Doors (AD) are tabled in the Door and Window
structural inadequacy 238.5 m 2
room over Schedule with the corresponding Door. For example
with 1800 high timber 7
9,705
10 refer to AD.01 for WD.01 where these exist as a
9,930
fence on top of concrete FF: Conc. HC WS
SHS
sleeper retaining wall.
AD.08
C1 WS
combined glazing unit.
mech ventilation MB MB Entry
Landscape
Balcony over
to mechanical engineers specification Set down
FF: Conc. TR Setdown joists in bath room and under W.M.
RB AD.06
50mm to allow fall to floor waste in tile
Landscape 4 x lockers
8
Recreation & RB TD.05 9 bedding. JH Secura flooring to be full
AW.07
620
4,610
waterproofed to puddle flange drain
Staff area. F F BL
90
41.0 m2 S WT 5 Timber stair to storage room. CD30.05 CD30.05
WS
Top of Wall
BR WS
PWD SHR 19.041 Notes:
WS
2,200
C HWS C Refer to CD10.02 for General Notes
19.18
A/C FF: Tiles
CD30.04 UP CD30.04
WT 1
WB WC and other building requirements.
3 x Bicycle spaces Landscape
150
D.P. REF. 19.050
D PJ PJ PJ
Refer to Schedule of exterior and interior
150
20
A4 A finishes, as well as Schedule of Fittings &
#LayID Existing wall cut down to U/S level of driveway 18.99 Fixtures for more information and other
E linings fixed to furring D building requirements.
30.02 30.04 Existing wall Top of Wall
channels to tilt panel wall
T.O.W RL 22.19
18.38
Nail in Kerb
4,250 1,300 150
1,000 150 13,805 90 2,800 90 6,915 150 2,700 19,220
27,700
1 2 3 4
*Sewer line plotted from records*
*Water Main line plotted from records*
*Telstra/NBN line plotted from records*
E1
CD
GROUND FLOOR
Scale 1:100
0 5 10 20
REV DESCRIPTION DRAWN DATE
project drawing
A BUILDING APPROVAL AC/NN 03/08/22
B BUILDING APPROVAL AC/NN 12/08/22 Suite 2, Suncoast Resort Business Centre PROPOSED NEW INDUSTRIAL GROUND FLOOR PLAN
C
D
BUILDING APPROVAL
B.A - AS BUILTS FOR CERTIFICATION
KT/AC
NN
13/09/22
08/08/24
Cnr Gardak Street
SUNCOAST & Surf Road
RESORT BUSINESS CENTRE WAREHOUSES
Alexandra
SUITE 2 Headland Q 4572
CNR GARDAK ST & SURF RD Copyright of this document remains the exclusive
for property of SPROUT ARCHITECTS PTY LTD
POALEXANDRA HEADLAND
Box 6232, Maroochydore BC Q 4558 Qld 4572 ABN 23 123 917 724.
PO BOX 6232 MAROOCHYDORE BC Qld 4558 OLD SEA DOG 9 PTY LTD date 8/08/2024 drawn KT/AC scale AS SHOWN Contractors are to verify all dimensions and levels on
P PH
07 :5443 5028
07 5443 F 07 5479 2380 | ABN
5028 FAX:07235479
123 917
2380724 @ A1
N
at site prior to commencing. Report all discrepancies to
[email protected]
ABN | sproutarchitects.com.au
23 123 917 724 9 BARTLETT ROAD NOOSAVILLE QLD
the Architect. Use figured dimensions in preference
to scaled.
EMAIL: [email protected] drawing no. 21015 CD20.01 revision D
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.