Council archive · source document
Court Order approved extension of currency 2013 · 132008.176
Attached to the e-mail 132008.176.03 Extend the relevant period for 132008 176 - Lots 10 & 11 - 3 & 7 Serenity Close Noosa Heads.
be located so that they are convenient and safe to use (refer to Noosa Council Waste Management Code). The Plan shall contain the following information: a. The site area for the storage and separation of waste is to be shown on the plan drawings accompanying the application. b. A waste management table as indicated below is to be completed showing how waste material is to be segregated - recycled — reused or disposed. MATERIALS ON-SITE DESTINATION Re-use and Recycling Disposal Expected waste Estimated | On-site Off-site “specify contractor materials volume “specify proposed ‘specify contractor | and landfill site or (m?) re-use or on-site and recycling outlet | other disposal site recycling methods Excavation material Green waste Bricks Concrete Timber-please specify Plasterboard Metals - please specify Asbestos Other - please specify Noie * If a demolition contractor is undertaking works, then the Waste Management table is to be completed by the demolition contractor. The purpose of the Waste Management Plan is to facilitate the segregation of waste for the effective reuse and recycling of such materials. Additionally Council rewards those who segregate waste by significantly reducing disposal fees at the landfill some items are free. Higher gate fees are charged for loads of mixed waste. Trade Waste 101. 102. 103. The drainage system from all business that are likely to discharge trade waste must comply with Council's Trade Waste Policy and Sunshine Water’s guidelines for accepting trade waste into the sewer. All appropriate trade waste permit and/or agreements must be applied for and issued prior to the discharge of any trade waste to the sewer. Noise emission from mechanical equipment shall comply with the following requirements: Air-conditioning and Refrigeration a. 7am to 10pm: Maximum background + 5dB(A) b. 10pm to 7am: Maximum background + 3dB(A) Pumps c. 7am to 7pm: Maximum background + 5dB(A) d. 7pm to 10pm: Maximum background + 3dB(A) e. 10pm to 7am: No audible noise. : Written certification from a suitably qualified person shall be submitted confirming that the noise levels from all mechanical equipment comply when measured at either the residential boundary or outside the most exposed part of an affected building, whichever is the closest to the equipment. Page 12 of 13
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Court Order approved extension of currency 2013.pdfRelated documentApplication case desk ↗
Court Order approved extension of currency 2013.pdfRelated documentApplication case desk ↗
About this file
- File size
- 6.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.