HESSIAN 1 The designs, drawings and specification are copyright and always
BOUNDARY
50mm WIDE SIZE STAKES ANGLE CUT POST TOPS
REFER TO PLAN VIEW FOR remain the property of Blackburne Jackson Design Pty Ltd.
2200 CTRS MAX.
N 45 litre 50x50mm POST SIZINGS
27
2 Before commencing construction:
100mm DEEP MULCH AS SPECIFIED. -Verify all dimensions and levels.
STAKE AS 100 litre 75x75mm 15 TYPICAL
PLANT AS FORM SHALLOW DISH DRAIN TO 75 x 50mm F14 ACQ TREATED -Verify location and levels of all services on site.
SPECIFIED
SPECIFIED BASE OF PLANT TO ENSURE MULCH HARDWOOD RAIL
25
200 litre 100x100mm -Verify that floor levels and finished levels will enable connection to
IS NOT IN CONTACT WITH PLANT CLASS 2 H3. services.
W E STEM
3 Do not scale this drawing. When in doubt refer to Architects.
300mm TOPSOIL AS PER NOTES. ADD 100 x 25mm F14 ACQ
WATER CRYSTALS AND SLOW TREATED HWD FASCIA issue amendment log by date
RELEASE FERTILISER AS PER CLASS 2 H3 NAILED TO
TREE MANUFACTURERS SPECIFICATIONS. 75 x 50mm F14 ACQ HWD RAILS. A OPERATIONAL WORKS ISSUE KM 04-10-23
S REFER TO TABLE FOR STAKE SIZES. PALINGS/RAIL CLASS 2 H3 OVERLAPPED AT B OPERATIONAL WORKS ISSUE NQ 14-11-23
STAKES TO BE F14 HARDWOOD NON- CORNER POSTS AS SHOWN
TREATED STAKES FREE FROM KNOTS 150mm CULTIVATED SUB-SOIL C OPERATIONAL WORKS ISSUE NQ 05-12-23
& WARPS ETC. 19 D OPERATIONAL WORKS ISSUE NQ 19-12-23
100 x 25mm F14 ACQ
2200 CTRS MAX.
STAKES TO BE DRIVEN IN TO A 100 x 100mm F14 ACQ HWD END
HEIGHT TO ENSURE STAKE DOES NOT TREATED HARDWOOD FASCIA E OPERATIONAL WORKS ISSUE NQ 13-03-24
MULCH : CLASS 2 H3 NAILED TO POST. CLASS 1 H5 SEASONED
DAMAGE LOWER LATERAL LIMBS. F OPERATIONAL WORKS ISSUE NQ 19-03-24
STAKES TO BE CENTRALLY POINTED MULCH GARDENS TO A MIN DEPTH OF PALINGS AND RAIL
& DRIVEN VERTICALLY INTO GROUND 100mm WITH HOOP PINE BARK (CHIP G OPERATIONAL WORKS ISSUE NQ 16-05-24
NOTES:
OUTSIDE OF ROOTBALL, TO BE SIZE 10-25mm) FROM MATURE TREES, NEIGHBOURING SITE H REVISED OPERATIONAL WORKS ISSUE NQ 26-05-25
LOCATED IN NE & SW CORNERS FREE FROM WOOD SILVERS. DO NOT PROPERTY 15 x 100mm H4 ACQ HWD PALINGS
ROOT BARRIER TO BE APPLIED I REVISED OPERATIONAL WORKS ISSUE NQ 08-08-25
MOUND MULCH HARD UP AGAINST NAILED TO PALINGS/RAILS
UNLESS OTHERWISE SPECIFIED
PLANT STEMS. 15 x 100mm H4 ACQ HWD M10 CUPHEAD BOLTS.
PALINGS NAILED TO COUNTERSINK BOLT AS SHOWN.
INSTALL SOCKED AG-PIPE IN GRAVEL
50mm WIDE HESSIAN SECURED PALINGS/RAILS
SURROUND FOR DRAINAGE TO
PERIMETER OF BASE CONNECTED TO LOOSELY TO TREE & FIXED TO STAKE 75x100mm F14 ACQ HWD POST.
WITH FLATHEAD GALVANISED NAILS
DETAIL
STORMWATER AS REQUIRED CLASS 1 H5 SEASONED.
OR STAPLES HEIGHT OF HESSIAN TIE
TO BE ONE THIRD TO ONE HALF OF 02 NOTE: END POSTS TO BE
100X100mm.
DO NOT AUGER ROUND PLANTING OVERALL HEIGHT OF TREE SCALE 1:10
HOLES, HOLES TO BE SQUARE IN
-
SHRUB & GROUNDCOVER PLANTING IN GROUND
PROFILE TO AVOID ROOT GIRDLING 75 x 50mm F14 ACQ TREATED 100x25mm F14 ACQ TREATED HWD
MOUND MULCH AT EDGE OF PIT TO HARDWOOD RAIL FASCIA CLASS 2 H3 NAILED TO
COLLECT WATER TO FALL DOWN
CLASS 2 H3. PALINGS
EDGES OF TREE PIT
TUBESTOCK AS SPECIFIED
100
100mm MULCH AS SPECIFIED
PLAN VIEW (WITH CORNER)
100
LOCALISED LOWERING OF SOIL
WHERE PLANTING OCCURS TO 50
100
ENSURE WATER RUN OFF TO
PLANTING AREAS consultants:
ROOTBALL DEPTH
TREE PIT TO BE EXCAVATED TO
STRUCTURAL ENGINEER :
DEPTH OF ROOTBALL BACKFILLED JUTEMASTER TM PEGGED SECURELY [company name]
WITH FRIABLE IMPORTED TOPSOIL FENCE ON RETAINING WALL NOTES
VARIES
WITH 100 x 100mm CROSS CUT FOR PH : [number] [@email here]
(50%), MIXED WITH SITE SOIL (50%) PLANT FOOTINGS TO BE 20 MPa NO
MAX 2% ORGANIC CONTENT FIRMING - REFER CIVIL ENGINEERING DETAILS. CIVIL ENGINEER :
FINES CONCRETE - POSTS TO BE BOLTED TO RETAINING WALL POSTS, 100 x 75mm
PROGRESSIVELY [company name]
300 x 300 x 600mm WITH - RETAINING WALL POSTS TO BE 100 x 200mm PH : [number] [@email here]
125mm COARSE DRAINAGE - ALIGN 200mm WIDE FACE OF RETAINING WALL POST PARALLEL TO FACE OF HYDRAULIC ENGINEER :
LOCALISE TOPSOIL AROUND PLANTS GRAVEL UNDER RETAINING WALL TO ENSURE THAT FENCE POST IS FLUSH ON FRONT FACE [company name]
APPROX. 3x TIMES THE VOLUME OF
600
TO RETAINING WALL POST. PH : [number] [@email here]
ADD WATER CRYSTALS AND SLOW THE ROOT BALL.
RELEASE FERTILISER AS PER ELECTRICAL & MECHANICAL ENGINEER :
150
MANUFACTURERS SPECIFICATIONS. FENCE NOTES [company name]
PH : [number] [@email here]
- MAX HEIGHT OF FENCE TO BE 1800mm
- FENCE TO HAVE 3 RAILS, INTERMEDIATE RAIL TO BE CENTRED BETWEEN
TOP AND BOTTOM RAIL.
ENSURE EDGES OF PIT ARE POROUS. - FIXINGS TO BE HOT DIPPED GALVANISED UNLESS WITHIN 1KM OF THE
RIP CLAY SOILS IF REQUIRED 150mm CULTIVATED SUB-SOIL COAST WHERE FIXINGS SHALL BE 316 STAINLESS STEEL.
- WHERE FIXINGS ARE LIKELY TO SPLIT TIMBER, PRE-DRILL TO 80% OF FIXING
DIAMETER.
125
1200 x1200mm SQUARE HOLE - ALL EXPOSED EDGES OF TIMBER TO BE ARISED.
(Minimum 2x width of rootball) - TIMBER FINSHES AS SPECIFIED.
03 DETAIL - ALL WORK TO BE PERFORMED IN ACCORDANCE WITH RELEVANT
DETAIL
AUSTRALIAN STANDARDS.
01 -
BIORETENTION TUBESOCK PLANTING
SCALE 1:10
300
- CONTRACTOR TO BUTT JOIN RAILS WITH BATTEN SCREWS IF
RECOMMENDED TECHNIQUE IS DISMISSED WITH AGREEMENT BY
SCALE 1:10
-
TREE PLANTING IN GROUND SECTION ARCHITECT.
100 x 25 TIMBER EDGING TO BE FLUSH 07 DETAIL
PLANTING AS PER WITH TOP OF TURF AND MULCH AS SCALE 1:10
PLANTING PLAN PER LANDSCAPE SPECIFICATION
-
TIMBER PALING FENCE IN GROUND (FN3)
NOTES
BOUNDARY
TURF OR GRAVEL AS PER NOTES ANGLE CUT POST TOPS
REFER TO PLAN VIEW FOR
POST SIZINGS
27
BOUNDARY
75 x 50mm F14 ACQ TREATED
HARDWOOD RAIL
25
CLASS 2 H3.
100 x 25mm F14 ACQ
TREATED HWD FASCIA
COMPACT EARTH BEARING STRIP CLASS 2 H3 NAILED TO
UNDER GARDEN EDGE PALINGS/RAIL
19 100 x 25mm F14 ACQ
04 DETAIL TREATED HARDWOOD FASCIA
CLASS 2 H3 NAILED TO NEIGHBOURING
SCALE 1:10 SITE
PROPERTY
-
TIMBER EDGING PALINGS AND RAIL
PAINT FINISH TO
NEIGHBOURING SITE BOTH SIDES OF
2000 max. ABOVE NATURAL GROUND
PROPERTY ACOUSTIC WALL
NOM. 40mm THICK 15 x 100mm H4 ACQ HWD
STONE STEPPERS LIGHTLY COMPACTED
DECOMPOSED GRANITE (DECO) PALINGS NAILED TO
PALINGS/RAILS
BEDDING SAND LAYER EPS CORE TO
GEOFABRIC/WEEDMAT LAYER MANUFACTURER'S
BELOW ALL DECO SPECIFICATION
STEEL
REINFORCEMENT
75 x 50mm F14 ACQ TREATED RIBS TO
HARDWOOD RAIL MANUFACTURER'S
OPERATIONAL WORKS
CLASS 2 H3. SPECIFICATION
NOM. 200
GALVANISED FIXING BRACKET
TO STRUCTURAL ENGINEER'S
CEMENTITIOUS SKIN NOT FOR CONSTRUCTION
TO MANUFACTURER'S
SPECIFICATION SPECIFICATION
05 DETAIL FILL TO CREATE
CHECKED : ……...………………………………….
SCALE 1:10 50
-
PRECAST CONCRETE STEPPER LEVEL YARD
100 x 25 TIMBER EDGING LIGHTLY COMPACTED NOM. 40mm THICK A R CHIT E CT UR E | L A NDS CA P E | INT E R IOR | P ROJECT MA NA G E ME NT
DECOMPOSED GRANITE (DECO) STONE STEPPERS
FILL
37 Aerodrome Rd Maroochydore Qld
P.O. Box 154 Cotton Tree QLD 4558 phone 07 5443 3200
email [email protected] fax 07 5443 4030
project:
PROPOSED TOWNHOUSE DEVELOPMENT,
50
FOOTING TO 54 ELM ST. & 5 PEARL ST. COOROY
STRUCTURAL
ENGINEER'S
SPECIFICATION
NOM. 200 client:
ALTUM PROPERTY GROUP
title:
LANDSCAPE DETAILS
north date: SEP 2023
drawn: BM
LINE OF CONCRETE SLAB
08 DETAIL 09 DETAIL checked: GC
OF TERRACE OR BUILDING -
TIMBER PALING FENCE ON BLOCK WALL (FN2)
SCALE 1:10
- TYPICAL BOUNDARY ACOUSTIC WALL (FN6) SCALE 1:10 scale @ A1 : 1:10
WHERE APPLICABLE
scale @ A3 : 1:20
06 DETAIL project/drawing no. sheet: A1
7283_L07-01_I
SCALE 1:10
-
PRECAST CONCRETE STEPPER - PLAN
GSPublisherVersion 90.0.89.0
7283-26-Cooroy printed: Friday, 8 August 2025 11:32 am
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
App C - Landscaping Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.