Skip to the record
Search everything, all in one place.

Council archive · source document

Decision Notice - 010.2007.00001852.001 [As Published] · 132007.1852

of 6

Text shows just the words. Original shows the document exactly as it was published.

NOOSA COUNCIL IDAS Development Application Decision Notice                                                    3 of 6




                                    Noosa Council Conditions
                                    INTEGRATED PLANNING ACT 1997, IDAS DEVELOPMENT APPLICATION


Land Use
1.    Development undertaken in accordance with this approval must generally comply with the approved plans
      of development. The approved plans are numbered 1 of 17 – 6 of 17, prepared by Good Building Design
      and dated 22 November 2006 and as may be amended by these conditions.

2.    The development must be undertaken and operated in a manner that causes no detrimental effect upon
      the amenity of the neighbourhood by reason of the creation of excessive noise, lighting nuisance or other
      emissions.

3.    Existing trees on the site and within road reserves are to be retained, except where required to be
      removed due to building operations or the conduct of the approved use.

4.    The dwelling house is not to exceed a height of 8.0 metres and 2 storeys above natural and finished
      ground level.

5.    A verification survey of the building is to be carried out by a Licensed Surveyor and a certificate lodged
      with Council at completion of work confirming compliance with the maximum allowable building height as
      required by either the conditions of approval or the Planning Scheme.

6.    All hot water systems installed shall be either solar systems; electric heat pump systems; or gas systems
      (LPG or natural).

7.    The proposed development shall have all kitchen, laundry and bathroom fittings that comply with the AAA
      Water Conservation Rating System as defined by the AS/NZS 6400 (Water Efficient Products - Rating
      and Labelling 2003) and AS/NZS 3500 (National Plumbing and Drainage Standard Part 1.2), with toilets to
      comply with the AAAA Water Conservation Rating System. All tap ware and shower roses shall not
      exceed a maximum flow of 9 litres per min. Dishwashers and washing machines are excluded from this
      requirement.

8.    The Development Permit for a material change of use of premises lapses if the use has not happened by
      9 November 2011, unless an application to extend the currency is approved by Council.
Land Development

Contributions Towards Council Infrastructure
9.    Monetary contributions shall be paid to Noosa Council towards the cost of providing and/or upgrading
      various infrastructure at the rates applicable at the time of payment. An estimate only of the contribution
      amounts under the current Council policies and requirements is outlined in the table below:

        Contribution Required For:                                                             Amount:

        PSP20 – Pathway Trunk Network Contributions                                            $ 675.-
        TOTAL Contribution Amount =                                                            $ 675.-
        Please note, that these amounts are all subject to variations in the Consumer Price Index, All Groups Brisbane
        from SEPTEMBER 2007 until the date of payment.
      All contributions must be paid prior to the commencement of the use.

Stormwater Drainage
10.   Roof runoff from any new dwelling shall be directed to a rainwater storage system or tank (minimum
      storage 5,000 litres per dwelling) that is installed to ensure water from the tank can be used for external
      uses (such as watering gardens, irrigation, ornamental ponds, water features, topping-up swimming pools,
      outdoor cleaning, etc) and for use in flushing of toilets internal to the dwelling. All rainwater tanks are to
      be designed and installed in accordance with the Queensland Development Code (QDC), Part 25 –
      Rainwater Tanks, and shall be part of the plumbing application in conjunction with the building approval.
      The location and capacity of the tank shall be clearly shown on the plans submitted for Building Works
      approval and any overflow shall be directed to the stormwater drainage system.




AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@4007d0c0\@[email protected]

Used in these records

About this file

File size
29 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Decision Notice - 010.2007.00001852.001 [As Published].pdf · 29 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.