GeoConsulting, Report #15988, July 11 Page 12
Lot 34 Marcus Dues Court, Marcus Beach
7. CONCLUSIONS
7.1 Recommendations
Notwithstanding the following conclusions, it is recommended:
♦ Minimise cut/fill earthworks. Sheet piling or other retention devices should be considered to
stabilize the cut embankment during construction.
♦ It is proposed to retain the cut embankment with the retaining wall to be incorporated into
the residential structure. The retaining wall is to be designed by a suitably qualified engineer
and in accordance with the recommendations made herein.
♦ Foundations are to be designed based on the bearing capacity given in Tables 1 - 3 in Section
3.2.9 of this report.
♦ Install and maintain drainage systems to divert water away from the proposed residence
7.2 Slope Stability Risk
It has been concluded that this geological region has a negligible to low risk of slope instability.
Movements are typically in the form of hillside scour and slumping from concentrated runoff and / or
inappropriate earthworks. With maintenance to the surface drainage, founding to depths as discussed and
temporary/final retention of cut/fill areas, then the risk will not preclude building. Construction should be
in accordance with the recommendations made herein, amended and / or reinforced by structural design.
It has been concluded that this geological region has a low risk of slope instability and with the adoption
of our recommendations; this risk can be maintained as "low". Construction should be in accordance with
the recommendations made herein, amended and / or reinforced by structural design.
t A summary of the identified hazards on Lot 34 is presented in Table 6 with risk assessment prior to and
subsequent to the recommendations made herein.
Table 6 Final Risk Assessment Matrix
I Identified Hazard
Existing Risk
Assessment
Risk Assessment
Subsequent to
Recommendations
1. Hillside slope failure:-
Lower than dwelling Low Very Low
At dwelling site Low Very Low
Above dwelling site Low Very Low
2. Unsupported batters: -
Cut Low to moderate Very Low
Fill Low to moderate Very Low
3. Rendered cobble wall Low to moderate Very Low
office at: 1/8 Denna St, Maroochydore, Q, 4558.
Phone: 5443 6622, Fax: 5479 1899, Email: admin&geoconsulting.com.au
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application Part 2 of 2 Planning report Geotechnical report and plans MCU11/0168 & OPW11/0257Related documentApplication case desk ↗
Development Application Part 2 of 2 Planning report Geotechnical report and plans MCU11/0168 & OPW11/0257Related documentApplication case desk ↗
About this file
- File size
- 12.5 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.