in Figure 2.2 of AS2890.1. Minimum requirements for 90 degree angle parking bays
include a minimum width of 2.6m, length of 5.4m and aisle width of 5.8m.
Parking for disabled spaces must comply with AS2890.6 with a 2.4m wide space and
adjacent 2.4m shared area.
Compliance with Australian Standards AS2890.1
Parking spaces within the site are indicated on the layout provided by
Blackburn Jackson.
All parking spaces are a minimum width of 2.6m, length of 5.4m with a
minimum aisle width of 6.0m. The proposed parking spaces comply with
AS2890.1 (Figure 2.2). A further 300mm is provided for space 28, 38 and 47
that is adjacent to a wall. A turn bay has been provided to facilitate turning
manoeuvers within the basement car park.
Motorcycle spaces comply with the requirements of Clause 2.4.7 and Figure
2.7 of AS2890.1
The proposed disabled parking space complies with the requirements of
AS2890.6:2009 Figure 2.3 and is conveniently located close to the pedestrian
access ramp into the building.
The headroom clearance in the basement complies with the minimum
requirement of 2.2m as outlined in Clause 5.3.1 of AS2890.1.
In summary the proposed car parking spaces and aisle widths comply with the
requirements of AS2890 and are considered adequate and suitable for the