Landscape Technical Specification - OPW14/0197
Attached to the e-mail Doonella Stage C (Email 7 of 7) Landscape Technical Specification & Transmittal - OPW14/0197.
Doonella – Stage C 4. STORMWATER AND DRAINAGE 4.1.1 GENERAL The Contractor shall be responsible for all aspects of coordination with Hydraulic works by other trades. Refer also to Hydraulic Engineers drawings Drainage locations shown on but not limited to: Landscape Plans Landscape Plans are indicative only. All drainage requirements are to be checked, confirmed and documented by the Hydraulic Engineer. Refer to Hydraulic Documents for actual drainage requirements for type, size and capacity. Refer to this specification for grate type/ finishes only. Submit samples for approval prior to installation. Refer to Engineers drawings for load capacity requirements. 4.1.2 CROSS REFERENCES General: Conform to the General requirements section. 4.1.3 MATERIALS Subsoil: To AS 2439.1. Pits and Channel Grates: Located with reference to the Landscape Levels and Drainage Plans. Refer to Engineer’s details for type, size and capacity. 4.1.4 STORMWATER General: Refer to Engineer’s details 4.1.5 SUBSOIL DRAINS General: Provide subsoil drains to intercept groundwater seepage and prevent water build-up behind walls and under floors and pavements. As required or as shown on the drawings. Connect subsoil drains to surface drains or to an approved stormwater drainage system as applicable. Points and method of connection to stormwater system to Hydraulic Engineers details. Subsoil drainage shall be constructed in accordance to AS/NZS 3500.3:2003. Unless specified otherwise, subsoil drainage trenches shall incorporate geotextile material lining the trench. Trench width: ≥ 450 mm. Pipe depth: Provide the following minimum clear depths, measured to the crown of the pipe, where the pipe passes below the following elements: 100 mm below sub-grade level of the pavement, kerb or channel. 100 mm below the average gradient of the bottom of footings. 450 mm below the finished surface of unpaved ground. 4.1.6 SUBSOIL DRAINAGE GEOFABRIC MATERIAL Geotextile material used in subsoil drains shall be a non-woven type and shall have the following properties prior to exposure to sunlight at the site. Geotextile strength rating (G) of greater than 900 Flow rate under 100 mm constant head as determined using the Permittivity Test procedures stated in AS 3706.9 of greater than 501/m2/s. AECOM 1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.