5. EDGING
5.1 GENERAL
Set edging’s flush with adjoining surfaces to define new planting, grass areas or both.
5.2 CONCRETE EDGE
Supply and install 100 x 100 continuous concrete edging to profile as detailed on the drawing.
Finish: being steel trowel.
Ensure subgrade has been suitably compacted before installation. Concrete is to be a minimum 20Mpa.
No coloured oxide is required to the edging.
Plan reference code: Description: Colour: Pattern / Finish;
CE Insitu extruded To match: Smooth float finish
concrete edging to extruded from mobile
profile as specified Standard Grey (non hopper.
and detailed. coloured concrete).
TE Treated Pine N/A N/A
45 x 75mm
END OF SECTION