13. FENCES
13.1 GENERAL
All fences to be powder coat steel / Aluminum to meet Ipswich City Council requirements. Location of
fences to be confirmed on site with landscape superintendent.
13.1.1 FENCE TYPE 1
Supply and install Fence Type 1 to the locations where shown on drawings. The fence system shall
comprise of powder coated tube posts, hardwood top rail with horizontal galvanised fencing wire.
Latch: Hot dip galvanised heavy duty top latch and galvanised drop bolt
Construction: Refer to details on drawing L-4304-Stage C-903
ITEM DESCRIPTION SIZE
F1 Post (incl gate posts) H4 treated hardwood Refer to timber
schedule
F1 Top Rail H4 treated hardwood Refer to timber
schedule
Fencing wire (horizontal) Galvanised medium tensile fence wire 2.5mm
Bracing Hot dip galvanised steel bracing rod & tensioner 16mm rod
with painted cold galvanised end plates and welds
Gate frame & diagonal Hot dip galvanised RHS steel gate frame - all joints 1500mm x 1500mm
brace rod CFW gate frame RHS 38mm
x 25mm x 2.0mm
Hot dip galvanised steel bracing rod welded to
frame corners 12mm brace rod
Hinges Hot dip galvanised heavy duty hinge welded to -
gate frame & coach screwed to timber post
13.1.2 FENCE TYPE 2
Supply and install Fence Type 2 to the locations where shown on Civil Engineers drawings.
ITEM DESCRIPTION SIZE
F2 Supplier: ‘ARC Fences’ or approved equivalent. Install as per 1200H
suppliers specification.
END OF SECTION