Z40770_Response to InformationRequest_NC_final
Attached to the e-mail Response to Information Request MCU16/0112 & OPW16/0209.
1 INTRODUCTION
SCG Consulting Engineers has performed a limited site investigation and established a site classification in
accordance with AS 2870-2011 and made recommendations based upon the classification for a building to be
constructed at the above site. This report does not include an assessment of Slope Stability, Landslide Risk, or
specifications for damp proofing, termite protection or moisture barriers.
This soil test and footing report relates only to the above property and the proposed construction as described
below:
Proposed Construction Industrial Building
External Walls Concrete
Internal Walls Various
Ground Floor Slab on Ground
Building Platform Cut Fill Pad
This report must be read and considered as a whole. All of our recommendations,
foundation plans, sections and appendices must be read, considered and followed by all
people involved in this project including the client to ensure adequate long term performance
of the footing system constructed on this site. A copy of this report must remain with the
client or final owner of the building upon completion of the proposed works. If you are
unsure of any of the requirements herein, you must seek clarification from this office.
2 SITE CLASSIFICATION
After considering the results of our field investigation performed on 25/10/2016 we have classified this site in
accordance with AS 2870-2011 as:
Class H1
The classification has been calculated from test work performed on the soil profile encountered on the day of
our fieldwork and consideration of AS2870-2011. Any disturbance of the soil profile may result in a change to
the classification.
The site preparation details that follow have allowed for the influence of the earthworks described in section 5.0
below.
Site Classification: The site classification is calculated in accordance with the “AS2870-2011 Residential
Slabs and Footings-Construction” and relates to the estimation of Ys, “The characteristic surface movement”
within reactive soil profiles. The limits used for this classification are as follows:
Predicted Surface Movement Classification
Ys = <=20mm S Slight
Ys = >20 – 40mm M Moderate
Ys = >40 – 60mm H1 High-1
Ys = 60 – 75mm H2 High-2
Ys = > 75mm E Extreme
Problem sites P Problem
3 SITE DESCRIPTION
The construction area has a gradient in the order of 3%.
Vegetation on the construction area (and nearby surrounds) consists of grasses.
The existing surface drainage is fair and sub-surface drainage is poor.
4 FINDINGS
The soil profiles encountered are shown on the attached borelog sections.
SCG Consulting Engineers 1 SCG Ref: 26232(S)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.