11. No flood lighting must be used on site. Any vertical illumination resulting from direct, reflected
or other incidental external lighting emanating from the site must not exceed 8 lux when
measured at any point 1.5 metres outside the boundary and at any level from ground level
upward.
Environment
12. Sediment or any other material including building materials or waste products must not be
deposited or released into the road reserve, stormwater drain or adjacent properties.
Landscaping Works
13. A minimum of 20% of the site must be retained as soft landscaping.
14. Areas of the site proposed to be cut or filled to establish the approved development are
required to be landscaped and returned to a either a grassed or landscaped setting. Areas
of exposed earth hillside resulting from the development is not approved.
15. Existing vegetation in the road reserve must be retained, unless written authorisation from
Council is granted for the clearing.
16. All excavation/fill and associated batters must be contained entirely within the subject site
unless written permission from the respective landowner(s) is provided to Council. All
earthworks must be undertaken in accordance with the provisions of Australian Standard
AS3798: Guidelines on Earthworks for Commercial and Residential Developments.
17. All retaining walls must be designed and constructed in accordance with the planning scheme
and must be certified by an RPEQ where exceeding 1.0m in height.
Water Supply
18. The approved dwelling must be serviced with a rainwater tank having a minimum storage
capacity of no less than 60,000 litres.
Site Access and Driveways
19. An access driveway must be provided from Lukes Rd to all parking and manoeuvring areas
of the development. The works must be undertaken in accordance with Driveway Levels Plan
Part 1 & 2 prepared by SCG Engineers (00577-OW4.1 & 00577-OW4.2) and dated February
2026.
Stormwater Drainage
20. Stormwater runoff from the development must be disposed of on-site without causing scour
or damage to the subject site or any adjoining property.
Easements
21. Unless otherwise agreed in writing by the relevant service provider, any public or third party
infrastructure located on the subject site must be placed within an easement registered
against the title of the property.
22. All easements must be designed in accordance with the planning scheme and granted at no
cost to the Grantee. Where the Grantee is Council or a service authority, the easement
documentation must be in accordance with the Grantee’s standard easement terms. Draft
easement documentation must be submitted to Council for endorsement.
23. All works must be kept clear of any existing or proposed easements on the subject land,
unless agreed otherwise in writing by the Grantee.
Geotechnical Stability
24. All works must be carried out in accordance with the recommendations contained in Slope
Stability Assessment (26020-001-Rev0), prepared by tectonic and dated 13 February 2026,
listed within this Decision Notice.
Page 14 of 21
Document Set ID: 24620687
Version: 4, Version Date: 28/04/2026
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Delegated Report - Code - Planning MCU26 0012 (As Published).pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.