              13. Any construction and post construction activity is not to impact on the condition of the
                  waterway, and is to be conducted so as not to breach the Environmental Protection Act
                  (EPA) 1994.

              14. Construction works should be undertaken so as not to impact on the receiving waters.

              15. There is to be no loss of flood storage as a result of any use or development activity in
                  the area at an elevation below the 1 OOyr ARI flood level.

              16. Rock scour protection, wrapped in geotextile, extends 750 mm from the face of the
                  revetment wall in this locality. Piles are to be located clear of this rock protection.
              17. ft is important to note that any works that have been constructed prior to the approval of
                  Engineering Drawings may, under the direction of the Chief Executive Officer, require
                  reconstruction to suit Council’s requirements. This work shall be undertaken at the cost
                  of the applicant.
              18. Any deviation from the approved Engineering Drawings that may occur in the field as a
                  result of on site or in-situ conditions will require that amended Engineering Drawings
                  are submitted for further assessment.
    f
             19. Any approval granted does not warrant that such plans and specifications have been
                 checked in detail, nor does it absolve the owner of the land from complying with all the
                 conditions of this approval and/or relevant Council By-Laws and Policies and/or
                 relevant statutes and/or statutory regulations in the execution and/or performance of
                 said works. Neither the Council nor the Chief Executive Officer accepts any
                 responsibility for the accuracy of such plans and specifications as approved. It is to be
                 noted that variations and/or additions to the approved plans may be required as directed
                 by the Chief Executive Officer, as a result of insufficient detail on the plans or to ensure
                 that Council Policies and/or good engineering practices are achieved.

             20. There shall be no electrical reticulation system carrying electricity in excess of 24 volts
                 beyond the revetment wall.

             21. This approval lapses where the construction of the jetty has not commenced within two (2)
                 years of the date of issue of the approval, unless application is made and approved by
                 Council for an extension.

    c   Please return the attached ‘Request for Inspection” cards prior to the works being commenced
        and also prior to completion. Upon completion of the relevant works and their inspection and
        approval by Council’s Development Section, arrangements will be made for the return of the
        $500.00 bond.

        Yours faithfully,




        Shane Adamson
        MANAGER - LAND USE




i
        DU r \nmr}\\\<nr/1\rlnr\iptti0c\lptiprv\1 $Jni-77chn}-phsivp)i Hnr

Used in these records

About this file

File size
11.5 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Operational Works Application OPW21_0044 - DA Form 1 - Cover Letter - Plans - copy 15203 DA - 77 Shorehaven Dr Noosa Waters.pdf · 11.5 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.