Original source · versioned page text
Architectural Plans - 711 Louis Bazzo Rd Cootharaba
Plans and drawings: the text below has words only, no drawings.
VE N.G.L.
8.5m ABO
EXISTING ROOF FRAMING
ZINCALUME SHEETING AT
APPROXIMATELY 22-26
EAVES 300
EXISTING 75mm HWD
WALL FRAMING
CEILING HEIGHT
WEATHERBOARD
CLADDING
3250
BEDROOM LOUNGE
APPROX. 7666
VERANDAH
EXISTING 100 x 50
HWD FJ AT 450 CRS.
EXISTING HARDWOOD FLOORING
EXISTING 100 x 75
HWD BEARERS EXISTING 2/180 PFC STEEL BEAM
HEIGHT ABOVE F.S.L.
SHS COLUMNS
2400
(REF. ENG. SPEC.)
N.G.L.
APPROX.
APPROX. F.S.L.
REFER TO ENGINEER'S
SPECIFICATIONS FOR
FOOTING DETAIL.
SECTION A-A
Scale 1:50
NOTE:
The structural drawings are indicative only and require to be
confirmed with structural engineer prior to work. AM20 Design does
not accept any responsibility for the structural components and their
designs for the proposed dwelling. Structure Engineer's drawings
take precedence over AM20 Design drawings and documents.
REV DESCRIPTION DATE DRN. APPRVD. WARNING NOTICE: COPYRIGHT AND REPRODUCTION Project Address Client
A ISSUED FOR DESIGN APPROVAL 05.08.2024 MP AM 1. Engineer's and or Manufacturer's 1. This document is Confidential and remains the
property of AM20 Design. Accordingly, copies of this
K & J CHADBURNE
B REVISED SITE PLAN 14.10.2024 MP AM
Designs & Specifications to take
precedence over this document. document must not be distributed to third parties PROPOSED DWELLING AT Sheet
2. All contractors to confirm all levels, without their prior written consent. Scale 1 : 50 at A3
C REVISED SITE PLAN 06.02.2025 MP AM angles and dimensions on site
before commencing work.
2. A third party receiving a copy of this document should
not place any reliance upon it and AM20 Design.
0 0.5 1.0 1.5m 711 LOUIS BAZZO ROAD SECTION A-A'
disclaims all responsibility and liability to such party.
3. All construction to comply with the
Building Code of Australia 2022 3. This document may not be altered mimicked or COOTHARABA Project Drawing Revision
and current Australian Standards. reproduced without written approval from AM20
4. Do not scale off drawings. Design. Code 900217 No. CHA-008 C
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the original