Council archive · source document
SUPERSEDED Compiled Approved Plans - 51983.3225.23 (As Published)
Plans and drawings: the text below has words only, no drawings.
NOOSA COUNCIL
APPROVED PLAN
51983.3225.22 19 MAY 2025
[OCR of page images]
ADJOINING
VILLA
BOUNDARY
ADJOINING
VILLA
ROADWAY
ADJOINING
SHARED
4
q
BOUNDARY,
ROADWAY
~ BOUNDARY
~~ “BOUNDARY
(DEDICATED LOT
ADJOINING
VILLA
BOUNDARY
(DEDICATED LOT
EXCLUSIVE USE AREA)
7
7
——5
EXCLUSIVE USE AREA)
NOOSA COUNCIL
APPROVED PLAN
NOTE
UNLESS NOTED OTHERWISE, ALL EXISTING
BUILT WORKS ARE TO REMAIN. FOR FURTHER
CLARIFICATION ON EXTENT OF DEMOLITION
NOTES
1. ALL CONSTRUCTION WORK UNDERTAKEN
|S TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (BCA), RELEVANT
NOTE:
THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY
WAY FOR STRUCTURAL PURPOSES. REFER
TO STRUCTURAL ENGINEER'S DETAILS
WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL
ROOF MOUNTED SOLAR
PANEL SYSTEM AS SPECIFIED
TO NORTH FACING SIDE OF
EXISTING ROOF
BOUNDARY
ADJOINING
SHARED
ROADWAY
2, ALL SETBACK/SETOUT DIMENSIONS ARE
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION.
AN
AS
REQUIREMENTS.
NOTE:
ROOM DIMENSIONS
SHOWN ARE TO
FINISHED WALL FACES.
LEGEND
AW
COL
cT
DHW
DP
DRY
FW
DW
FGw
HB
AWNING WINDOW
STEEL COLUMN
COOKTOP
DOUBLE HUNG WINDOW
DOWNPIPE
CLOTHES DRYER
FLOOR WASTE
DISHWASHER
FIXED GLASS WINDOW
HAND BASIN
LVW LOUVRE WINDOW
OV OVEN
P PANTRY
REF REFRIGERATOR
SGD SLIDING GLASS DOOR
SGW SLIDING GLASS WINDOW
SHR SHOWER
SWP SANITARY WASTE PIPE
wc TOILET
WM WASHING MACHINE
CRITICAL NOTE: PARTITION WALLS SHOWN ARE BASED ON 70mm WIDE STUD FOR
APPROVAL PURPOSES ONLY. REFER TO STRUCTURAL ENGINEER'S DETAILS FOR ALL
FRAMING SIZING AND STRUCTURAL REQUIREMENTS THROUGHOUT PROPOSED
WORKS. WHERE 90mm STUD FRAMES ARE REQUIRED TO SUIT PROPOSED
STRUCTURE, BUILDER TO MAINTAIN EXTERNAL BUILDING FOOTPRINT AND ADJUST
(01. \ PROPOSED FLOOR PLAN - ROOF
Yo) SCALE 1:100
ROOM SIZES ACCORDINGLY ON INTERNAL SIDE, ENSURING MINIMUM INTERNAL
CIRCULATION WIDTHS ARE MAINTAINED (WHERE REQUIRED). ALL DIMENSIONS
SHOWN ARE FOR APPROVAL PURPOSES ONLY, STRUCTURAL LAYOUT TO BE
51983.3225.22 19 MAY 2025
CONFIRMED ON SITE BY PROJECT ENGINEER & BUILDER PRIOR TO CONSTRUCTION.
NOTES: AMENDMENTS PROJECT DRAWING CREATED SCALE @AB
4, THIS IS A COMPUTER GENERATED DRAWING. DO NOT AMEND BY HAND. REV DATE DESCRIPTION BY
+ Mn ae a MOLY AL IODRMD | a] ooe PaaS EON. FOR APPROVAL | proposed RESIDENTIAL ALTERATIONS AUG 2023 4:100
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS | 8 | 14.01.2025] PROJECT SCOPE ADJUSTMENTS 6a ‘ADDRESS PROJECTNO. REVISION www.gtgroup.net.au
« cowersckenisoumne 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 rus (Ci GI NO@)U ta tees
©.GT GROUP BULDING DESIGN. THESE ORAWINGS ARE PROTECTED BY [autor 68} DRAWING PWG. NO. ae
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED | ORIGINAL SHEET SIZE: A3 (420x297mm PROPOSED FLOOR PLAN - ROOF A104 ODETTE)
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED Compiled Approved Plans - 51983.3225.23 (As Published).pdfRelated documentApplication case desk ↗
About this file
- File size
- 9.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.